Network Camera Web3.0 Operation Manual Version 1.0.
Table of Contents 1 2 3 4 5 Network Connection ...................................................................................................... 1 Main Interface Introduction ............................................................................................ 2 2.1 Log in ................................................................................................................ 2 2.2 Live Interface .........................................................................................
6 7 5.2.10 Multicast ................................................................................................... 42 5.2.11 WIFI .......................................................................................................... 43 5.2.12 802.1x ....................................................................................................... 46 5.2.13 QoS .......................................................................................................... 47 5.2.14 3G .............
Important The following functions are for reference only. Some series products may not support all the functions listed below.
1 Network Connection These series network camera products support the Web access and management via PC. Web includes several modules: monitor channel preview, PTZ control, system configuration, alarm and etc. Please follow the steps listed below for network connection. Make sure the network camera has connected to the network properly. Network camera IP address and PC IP address shall be in the same network segment. If there is router, please set the corresponding gateway and subnet mask.
2 Main Interface Introduction 2.1 Log in Open IE and input network camera address in the address bar. For example, if your camera IP is 192.168.1.108, then please input http:// 192.168.1.108 in IE address bar. See Figure 2-1. Input your IP address here Figure 2-1 The login interface is shown as below. See Figure 2-2. Please input your user name and password. Default factory name is admin and password is admin. Note: For security reasons, please modify your password after you first login.
Figure 2-2 If it is your first time to login in, you may see the interface shown as in Figure 2-3.
Click on “Please click here to download and install the plug-in”. The system pops up warning information to ask you whether run or save this plug-in. See Figure 2-4. Figure 2-4 You must either run or save the file to local and install it. Follow the following steps. Click on run, you will see Figure 2-5 and Figure 2-6.
Figure 2-5 Figure 2-6 5
When plug-in installation completes, the installation page closes automatically. The web-end will refresh automatically, and then you can view video captured by the camera. 2.2 Live Interface After you logged in, you can see the live monitor window. See Figure 2-7 2 1 3 4 Figure 2-7 There are four sections: Section 1: Encode setup bar Section 2: System menu Section 3: Window function option bar Section 4: Window adjust bar 2.3 Encode Setup The encode setup interface is shown as in Figure 2-8.
Figure 2-8 Please refer to the following sheet for detailed information. Parameter Function Main stream In normal network width environment, main stream can record audio/video file and realize network monitor. You can set the main stream resolution if your device supports. If network width is not sufficient, you can use sub stream to realize network monitor. Sub (Extra) stream Protocol You can select stream media protocol from the dropdown list. There are three options: TCP/UDP/Multicast 2.
When the video is in the original status, click it you can select any zone to zoom in. In the non-original status, you can drag the zoom-in zone in specified range. Right click mouse to restore previous status. Click it; you can use the middle button of the mouse to zoom in/out the video size. You can snapshoot important video by clicking on this button. All images are memorized in system folder: \ picture download (default).
Click this button to display/hide image control interface. 2.6.2 Original size Click this button to go to original size. It is to display the actual size of the video stream. It depends on the resolution of the bit stream. 2.6.3 Full screen Click it to go to full-screen mode. Double click the mouse or click the Esc button to exit the full screen. 2.6.4 Width and height ratio Click it to restore original ratio or suitable window. 2.6.
Please refer to the following sheet for detailed information. Parameter Function Adjust lens focal length. May adjust via single clicking on or long pressing + - . Zoom Step length is to adjust length of single step. Adjust lens definition. May adjust via single clicking on or long pressing + - . Focus Step length is to adjust length of single step. Automatically adjust image definition. Click to adjust. Auto focus Note: During auto focus, you cannot perform other lens operation.
It is to adjust monitor video hue. >Camera->Conditions to adjust corresponding items. It is to adjust monitor video saturation. Reset Restore brightness, contrastness saturation and R hue to systemedefault setup.
3 PTZ Control Please note only some series product support PTZ function. Before PTZ operation, please make sure you have properly set PTZ protocol. (Please go to Setup>System->PTZ to set.). Here you can view direction keys, speed, zoom, focus, iris, preset, tour, pan, scan, pattern, aux close, and PTZ setup button. See Figure 3-1. PTZ direction: PTZ supports eight directions: left/right/up/down/upper left/upper right/bottom left/bottom right. Speed: It controls rotation speed.
Figure 3-2 Please refer to the following sheet for PTZ setup information. Parameter Function Scan Preset Tour Pattern Click Setup button, you can set scan left and right limit. Move the camera to you desired location and then click left limit button. Then move the camera again and then click right limit button to set a right limit. Input the preset value and then click Preset button, the camera turns to the corresponding position of the preset.
Parameter Function Assistant Please input the corresponding aux value here. You can select one option and then click AUX on or AUX off button. Light and wiper You can turn on or turn off the light/wiper.
4 Playback 4.1 Playback Interface The playback interface is shown as in Figure 4- 1. 2 3 1 4 Figure 4- 1 There are four sections: Section 1: Function of play Section 2: Date Section 3: File list Section 4: Progress bar 4.2 Function of Play The function of play is shown as in Figure 4- 2.
1 2 3 4 5 6 7 Figure 4- 2 1. Play: Play or pause video. 2. Stop: Stop video. 3. Play by frame: Skip to next frame. 4. Slow play: Slow down the video. 5. Quick play: Speed up the video. 6. Silent: Switch off/on sound. 7. Volume: Adjust volume of the video. Note: You must pause video before skipping to next frame. 4.3 Date There are various colors in calendar: Green: means currently selected date. Yellow: means current date has record file.
Figure 4- 3 Click on to enter file list. Double click on record file in the list and this file will be played. You can view file size, start and end time. Record type has four catagories: Green means general record. Yellow means motion detection record. Red means alarm record. Blue means manual record. Search: You can search record files by selecting specific time interval. Download: Click on this button, you can download file to PC.
Back: Click on this button, you will go back to calendar page. 4.5 Progress Bar means video in past 24 hours. means video in past 2 hours. means video in past 1 hour. means video in past 30 min.
5 Setup 5.1 Camera 5.1.1 Conditions Here you can view device property information. Slight differences may be found due to different network camera series. The setups become valid immediately after you set. See Figure 5-1. Note: Only motorized zoom lens device has zoom and focus function. Figure 5-1 Please refer to the following sheet for detailed information. Parameter Function Profile You may select normal, day and night mode. Brightness It is to adjust monitor window brightness.
Contrast It is to adjust monitor window contrast. The larger the number, the higher the contrast is. You can use this function when the whole video bright is OK but the contrast is not proper. Please note the video may become hazy if the value is too low. If this value is too high, the dark section may lack brightness while the bright section may over exposure . The value ranges from 0 to 100. The recommended value ranges from 40 to 60. The default value is 50.
Low noise Low motion blur Manual Auto Iris The video whole brightness can automatically change within the proper exposure range according to the different environments. The higher the gain max value is, the lower the noise is. For the same environments, the noise of the low noise mode shall be smaller than the noise of the auto mode. The video whole brightness can automatically change within the proper exposure range according to the different environments.
Day&Night It is to set device day/night mode switch independently from config file. Default is auto mode. Color: Device outputs the color video. Auto: Device auto select to output the color or the B/W video according to the device feature (The general bright of the video or there is IR light or not.) B/W: The device outputs the black and white video. Sensor input: It is for external connection to IR light to control day/night mode.
3D NR This threshold is mainly for multi-frame (at least 2) image processing. It reduces noise with info between a frame and previous frame. The higher the value, the better NR will be. Default is enabled. NR level ranges from 0 to 100. The recommended value to from 40 to 60. Default value is 50. Mirror It is to switch video left and right limit. This function is disabled by default. Cancel It is to cancel the operation in current interface and restore previously saved operation.
If you select schedule, you can decide detained day time interval and night time interval as in Figure 5-64. You can set 0:00 ~ 12:00 as day, and 12:00 ~ 24:00 as night. Figure 5-4 The zoom and focus interface is shown as in Figure 5-5. Figure 5-5 Please refer to the following sheet for detailed information. Parameter Zoom Function Adjust lens focal length. May adjust via single clicking on or long pressing + - . Step length is to adjust length of single step.
Focus Adjust lens definition. May adjust via single clicking on or long pressing + - . Step length is to adjust length of single step. Automatically adjust image definition. Click to adjust. Auto focus Note: During auto focus, you cannot perform other lens operation. Restore lens to zero to clear accumulated difference. Restore Note: Please restore default settings when needed. Refresh Sync lens and slide bar location after hardware zooming.
Please refer to the following sheet for detailed information. Parameter Function Main stream It includes general stream, motion stream and alarm stream. You can select different encode frame rates form different recorded events. Bit stream type System supports active control frame function (ACF). It allows you to record in different frame rates.
Parameter Watermark Sub stream Enable Bit stream type Function This function allows you to verify the video is tampered or not. Here you can select watermark bit stream, watermark mode and watermark character. Default character is DigitalCCTV. The max length is 85-digit. The character can only include number, character and underline. Please check the box here to enable extra stream function. This function is enabled by default. General bit stream. Encode mode There are three options: H.
Parameter I Frame Function Here you can set the P frame amount between two I frames. The value ranges from 1 to 150. Default value is 50. Recommended value is frame rate *2. 5.1.2.2 Snapshot The snapshot interface is shown as in Figure 5-7. Figure 5-7 Please refer to the following sheet for detailed information. Parameter Function Snapshot type There are two modes: general (schedule) and Event (activation). Image size It is the same with the resolution of snapshot (main stream or sub stream).
Figure 5-8 Please refer to the following sheet for detailed information. Parameter Function Privacy mask Time Title Channel Title Location Here you can privacy mask the specified video in the monitor video. System max supports 4 privacy mask zones. You can enable this function so that system overlays time information in video window. You can use the mouse to drag the time tile position. You can enable this function so that system overlays channel information in video window.
Figure 5-9 5.1.3 Audio Please note some series products do not support audio function. The audio interface is shown as below. See Figure 5-10. Figure 5-10 Please refer to the following sheet for detailed information. Parameter Function Audio enable Main stream: Recorded file only contains video by default. You need to check the audio box here to enable audio function. Sub (Extra) stream: Recorded file only contains video by default. You need to check the audio box here to enable audio function.
The TCP/IP interface is shown as in Figure 5-11. Figure 5-11 Please refer to the following sheet for detailed information. Parameter Function Host Name It is to set current host device name. It max supports 32-digit character. Ethernet Card Please select the Ethernet port. It is for the wire LAN by default. Please note for the -W series product, it has the wireless network card, and you can modify the default Ethernet port setup.
IP Version It is to select IP version. IPV4 or IPV6. You can access the IP address of these two version. IP Address Please use the keyboard to input the corresponding number to modify the IP address and then set the corresponding subnet mask and the default gateway. Preferred DNS DNS IP address. Alternate DNS Alternate DNS IP address. Enable ARP/Ping set device IP address service. You can use ARP/Ping command to modify or set the device IP address if you know the device MAC address.
Figure 5-12 Please refer to the following sheet for detailed information. Parameter Function Max connection It is the max Web connection for the same device. The value ranges from 1 to 20. The max connection amount is 20. TCP port The default value is 37777. You can input the actual port number if necessary. UDP port The default value is 37778. You can input the actual port number if necessary. HTTP port The default value is 80. You can input the actual port number if necessary.
HTTPs Enable The default value is 443. 5.2.3 PPPoE The PPPoE interface is shown as in Figure 5-13. Input the PPPoE user name and password you get from the IPS (internet service provider) and enable PPPoE function. Please save current setup and then reboot the device to get the setup activated. Device connects to the internet via PPPoE after reboot. You can get the IP address in the WAN from the IP address column. When PPPoE is on, please disable UPnP to avoid influence on dial-up.
Figure 5-14 Please refer to the following sheet for detailed information. Parameter Function Server Type You can select DDNS protocol from the dropdown list and then enable DDNS function. The QUICK DDNS protocol means you use your self-defined private protocol to realize DDNS function. Server Address DDNS server IP address Domain Name Your self-defined domain name. Username The user name you input to log in the server. Password The password you input to log in the server.
Figure 5-15 Parameter Function Server Type You can select DDNS protocol from the dropdown list and then enable DDNS function. The QUICK DDNS means you use your self-defined private protocol to realize DDNS function. Server Address DDNS server IP address. Under DDNS the default server address is www.quickddns.com Mode The default is auto, and you can select manual. Domain Name Auto and self-defined domain names are both MAC address.quickddns.com. You can self-define prefix.
Please note: You must set MAC address in the same network segment. Figure 5-16 5.2.6 SMTP (e-mail) The SMTP interface is shown as in Figure 5-17. Figure 5-17 Please refer to the following sheet for detailed information.
Parameter Function SMTP Server Input server address and then enable this function. Port Default value is 25. You can modify it if necessary. Anonymity For the server supports the anonymity function. You can auto login anonymously. You do not need to input the user name, password and the sender information. User Name The user name of the sender email account. Password The password of sender email account. Sender Sender email address.
In the Windows OS, From Start->Control Panel->Add or remove programs. Click the “Add/Remove Windows Components” and then select the “Network Services” from the Windows Components Wizard. Click the Details button and then check the “Internet Gateway Device Discovery and Control client” and “UPnP User Interface”. Please click OK to begin installation. Enable UPnP from the Web. If your UPnP is enabled in the Windows OS, the network camera can auto detect it via the “My Network Places”.
Figure 5-19 Please refer to the following sheet for detailed information. Parameter Function SNMP port The listening port of the proxy program of the device. It is a UDP port not a TCP port. The value ranges from 1 to 65535. The default value is 161 Read community It is a string. It is a command between the manage process and the proxy process. It defined the authentication, access control and the management relationship between one proxy and one group of the managers.
Parameter Function Trap port The destination port of the Trap information from the proxy program of the device. It is for the gateway device and the client-end PC in the LAN to exchange the information. It is a non-protocol connection port. It has no effect on the network applications. It is a UDP port not TCP port. The value ranges from 1 to 165535. The default value is 162.
You can use the browse of the Bonjour service in the same LAN to search the network camera device and then access if you do not know the network camera information such as IP address. You can view the server name when the network camera is detected by the Bonjour. Please note the safari browse support this function. Click the “Display All Bookmarks: and open the Bonjour, system can auto detect the network camera of the Bonjour function in the LAN. Figure 5-20 5.2.
Figure 5-21 Please refer to the following sheet for detailed information. Parameter Function Enable Select to enable multicast function. Main stream and sub stream cannot be used at the same time. Multicast address Main/sub stream multicast address is 239.255.42.42 and its range is 224.0.0.0~239.255.255.255. Port Multicast port. Main stream is 36666, sub stream is 36667and the range is 1025~65534. 5.2.11 WIFI Important: This function is for the device of WIFI module.
Figure 5-22 Please check the box to enable WIFI function and then click the Search SSID button. Now you can view all the wireless network information in the following list. Double click a name to connect to it. Click on refresh button to obtain the latest connection status. Click on add wireless ID, and add designated ID in dialog box. Please make sure that you can find the just added ID in list, otherwise you cannot use this ID. See Figure 5-23.
Figure 5-23 Figure 5-24 Some series products (with WIFI) support WPS connection, and it includes PIN code and PBC connection.
PIN code: Step 1. Input PIN code and SSID of router. Step 2. Click on connecting for WPS connection. PBC: Step 1. Check button and click on connecting. Step 2. Press QoS button on router and connect to WPS. Note: PBC connection steps can be interchanged, and interval cannot exceed 120s. See Figure 5-25. Figure 5-25 5.2.12 802.1x 802.1x (port based network access control protocol) supports manual selection of authentication method to control if device connected to LAN can join the LAN.
Figure 5-26 Please refer to the following sheet for detailed information. Parameter Function Authentication PEAP (protected EAP protocol). Username It needs the username to login, which is authenticated by the server. Password Please input password here. 5.2.13 QoS The QoS interface is shown as below. See Figure 5-27. Qos (Quality of Service) is network security mechanism. It is a technology to fix the network delay and jam problem and etc.
Figure 5-27 Please refer to the following sheet for detailed information. Parameter Function Real-time monitor The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets. Command The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets. Enable wireless QoS Check it to enable QoS. 5.2.14 3G Note: This function is only for series with 3G module. The 3G interface is shown as in Figure 5-27.
Figure 5-28 5.2.14.1 Dialing Setting The dialing setting interface is shown as in Figure 5-28.
Please refer to the following sheet for detailed information. Parameter Function Wireless connection type The default is auto and it supports dial-up, sms and incoming call. Enable Check to enable 3G module. Authentication This function depends on your local 3G provider. Dial-up This function depends on your local 3G provider. Username This function depends on your local 3G provider. Password This function depends on your local 3G provider.
Please refer to the following sheet for detailed information. Parameter Function SMS sending In event management, check corresponding sms, so when there is event, a sms will be sent to mobile phone in corresponding receiving list. To use this function, you shall check sms enable in event management interface. SMS enable Mobile phone numbers in the list can enable/disable dial-up function and reboot device by sending sms to SIM card in the device.
Parameter Function Working Period Here you can set arm/disarm period. Click on set button to open period setup menu. There are six periods every day for setup and you must check box in front of each period to enable it. System only memorizes one event during the anti-dither period. The value ranges from 0s to 100s. Here you can set motion detection region and its sensitivity and area.
Figure 5-32 See Figure 5-32.
Figure 5-33 Different colors represent different areas. Each area can set different detection zones. Detection zone cam be irregular and discontinuous. If device monitoring zone is large, user can sub-divide the area into several zones for better motion detect. Please refer to the following sheet for detailed information. Parameter Function Name Default area name includes Region0, Region1, Region2, Region3 and custom.
Delete all Clear all areas. Delete Delete selected area. 5.3.1.2 Video Masking The video masking interface is shown as in Figure 5-34. Figure 5-34 Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable this function. Working period You need to set arm and disarm time. Click on setup button to set. Record After record is enabled, video masking can activate video.
5.3.2 Alarm Please note some series products do not support this function. 5.3.2.1 Alarm activation The alarm activation interface is shown as in Figure 5-35. Figure 5-35 Please refer to the following sheet for detailed information. Parameter Function Enable After enabled, relay activation will work. Alarm input The default is alarm 1 and for some devices may be alarm 2. Working period Anti-dither This function becomes activated in the specified periods. There are six periods in one day.
Parameter Function Flash delay Means flash become off after a period of time when relay activation ends. Unit is in second, within 10s ~ 300s. Record System auto activates motion detection channel to record once alarm occurs (working with motion detection function). Record Delay System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s. Relay out Alarm delay There is 1-channel alarm output. Corresponding to motion detection alarm output port.
Please refer to the following sheet for detailed information. Parameter1 Function Enable After enabled, PIR alarm will work. Flash After enabled, when alarm occurs, the system will automatically turn on flash. Flash delay Means flash become off after a period of time when relay activation ends. Unit is in second, within 10s ~ 300s. The flash set interface is shown as in Figure 5-37. Figure 5-37 Please refer to the following sheet for detailed information.
Figure 5-38 Figure 5-39 Figure 5-40 59
Figure 5-40 Figure 5-41 Please refer to the following sheet for detailed information. Parameter Event Type Function Record The abnormal events include: no disk, no space, disk error, net error, offline, IP conflict. Threshold: You can set the minimum percentage value here. The device can alarm when capacity is not sufficient. You need to draw a circle to enable this function. System auto activates channel to record once alarm occurs (For offline type only. See Figure 5-41. ).
Parameter Function Send email After you enabled this function, the system can send out email to alarm the specified user. This function is invalid when network is offline or IP conflict occurs. 5.4 Storage 5.4.1 Record Schedule and Snapshot Schedule In these two interfaces, you can add or remove the schedule record/snapshot setup. See Figure 5-42 and Figure 5-43. There are three record modes: general (auto), motion detect and alarm. There are six periods in one day.
Figure 5-43 You can set specified dates as holiday. When snapshot of holiday is enabled, the selected dates will be snapshot/recorded according to holiday setup. 5.4.2 Destination The destination interface is shown as in Figure 5-44. It is to set the storage mode of the network camera record file or snapshot pictures. There are two options: local/FTP. You can only select one mode. System can save according to the event types.
Parameter Function Event Type It includes: general, motion detect and alarm. Local It saved in the Micro SD card. FTP It saved in the FTP server. The local interface is shown as in Figure 5-45. Here you can view local Micro SD card or disk information. You can also operate the read-only, write-only, hot swap and format operation. Figure 5-45 The FTP interface is shown as in Figure 5-46. You need to check the box to enable the FTP function. When network disconnect occurred or there is malfunction.
The record control interface is shown as in Figure 5-47. Figure 5-47 Please refer to the following sheet for detailed information. Parameter Function Pack Duration Here you can select file size. Default setup is 8 minutes. Pre-record Please input pre-record value here. For example, system can record the four seconds video in the buffer. The record begins from the fifth second. Disk Full Record mode Record stream There are two options: stop recording or overwrite the previous files when HDD is full.
Figure 5-48 Please refer to the following sheet for detailed information. Parameter Function Device No It is to set device name. Video Standard This is to display video standard such as PAL. Language You can select the language from the dropdown list. 5.5.1.2 Date and time The date and time interface is shown as in Figure 5-49.
Please refer to the following sheet for detailed information. Parameter Function Date format Here you can select date format from the dropdown list. Time Format There are two options: 24-H and 12-H. Time zone The time zone of the device. System time It is to set system time. It becomes valid after you set. Sync PC You can click this button to save the system time as your PC current time. DST Here you can set day night save time begin time and end time.
Figure 5-50 Enable anonymity login: Enable anonymity login, and input IP. No username or password is required, you can log in by anonymity (with limited rights). You can click logout to end your session. Add user: It is to add a name to group and set the user rights. See Figure 5-51. There are four default users: admin/888888/666666 and hidden user “default”. Except user 6666, other users have administrator right. The user 666666 can only have the monitor rights,.
Figure 5-51 Modify user It is to modify the user property, belonging group, password and rights. See Figure 5-522. Modify password It is to modify the user password. You need to input the old password and then input the new password twice to confirm the new setup. Please click the OK button to save. Please note, the password ranges from 0-digit to 32-digit. It shall include the number and letter only. For the user who has the account rights, he can modify the password of other users.
Figure 5-52 5.5.2.2 Group The group management interface can add/remove group, modify group password and etc. The interface is shown as in Figure 5-53. Figure 5-53 Add group: It is to add group and set its corresponding rights. See Figure 5-54. Please input the group name and then check the box to select the corresponding rights. It includes: preview, playback, record control, PTZ control and etc.
Figure 5-54 Modify group Click the modify group button, you can see an interface is shown as in Figure 5-55. Here you can modify group information such as remarks and rights. Figure 5-55 5.5.3 PTZ Please note only some series products support this function. The PTZ interface is shown as in Figure 5-56.
Figure 5-56 Please refer to the following sheet for detailed information. Parameter Function Protocol Select the corresponding dome protocol. Address Set corresponding dome address. Default value is 1. Please note your setup here shall comply with your dome address; otherwise you can not control the speed dome. Select the dome baud rate. Default setup is 9600. Baud Rate Data Bit Default setup is 8. Please set according to the speed dome dial switch setup. Stop bit Default setup is 1.
Figure 5-57 5.5.5 Import/Export The interface is shown as in Figure 5-58. Figure 5-58 Please refer to the following sheet for detailed information. Parameter Function Import It is to import the local setup files to the system. Export It is to export the corresponding system setup to your local PC. 5.5.6 Auto Maintenance The auto maintenance interface is shown as in Figure 5-59. Here you can select auto reboot and auto delete old files interval from the dropdown list.
Figure 5-59 5.5.7 Upgrade The upgrade interface is shown as in Figure 5-60. Please select the upgrade file and then click the update button to begin firmware update. Important Improper upgrade program may result in device malfunction! Figure 5-60 5.6 Information 5.6.1 Version The version interface is shown as in Figure 5-61. Here you can view system hardware features, software version, release date and etc. Please note the following information is for reference only.
Figure 5-61 5.6.2 Log Here you can view system log. See Figure 5-62. Figure 5-62 Please refer to the following sheet for log parameter information. Parameter Function Type Log types include: system operation, configuration operation, data operation, event operation, record operation, user management, log clear. Start time Set the start time of the requested log. End time Set the end time of the requested log.
Parameter Function Search You can select log type from the drop down list and then click search button to view the list. You can click the stop button to terminate current search operation. You can select one item to view the detailed information. Log information Clear You can click this button to delete all displayed log files. Please note system does not support clear by type. Backup You can click this button to backup log files to current PC. 5.6.
6 Alarm Please note some series product does not support this function. Click alarm function, you can see an interface is shown as in Figure 6-1. Here you can set device alarm type and alarm sound setup. Figure 6-1 Please refer to the following sheet for detailed information. Type Parameter Function Alarm Motion detection System alarms when motion detection alarm type occurs, Disk full System alarms when disk is full.
7 Log out Click log out button, system goes back to log in interface. See Figure 7-1. Figure 7-1 Note: This manual is for reference only. Slight difference may be found in user interface. All the designs and software here are subject to change without prior written notice. All trademarks and registered trademarks mentioned are the properties of their respective owners. If there is any uncertainty or controversy, please refer to the final explanation of us.