Copyright@Shenzhen Sun Wealth Technology Co, Ltd. Hub Quick Start Guide Version With Editor Date V1.0 Draft Alice September 6, 2019 V2.0 Supplement the power supply connection Alice September 9, 2019 V2.1 Change to finish good photo Robust Dec. 25th, 2019 V2.2 Add wiring instruction Robust Feb. 10th ,2020 V2.3 Add wiring diagram and Safety statement Robust Feb.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. Technical Specification 1. Power : Rate : 24VAC (common wire requirement) Frequency : 50/60Hz 2. Weight of Unit: 0.5 Kg 3.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. CAUTION 1. Risk of explosion if the battery is replaced by an incorrect type 2. Use the battery only under the following environmental conditions. Failure to do so can result in reduced performance or a shorten service life. Recharging the battery outside of these temperatures can cause the battery to overheat, explode or catch fire.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. Warning 1. Do not use the battery if it gives off an door, generates heat, becomes discolored or deformed, or appears abnormal in any way. If the battery is in use or being recharged, remove it from the device or charger immediately and discontinue use. 2. Replace a BATTERY with incorrect type that can defeat a SAFEGUARD (for example, in the case of some lithium BATTERY types); 3.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. Danger Failure to observe the following precautions may result in battery leakage, overheating, explosion and/or fire. 1. Do not immerse the battery in water or allow it to get wet. 2. Do not use or store the battery near sources of heat such as a fire or heater. 3. Do not connect the battery directly to wall outlets or car cigarette-lighter sockets. 4. Do not put the battery into a fire or apply direct heat to it. 5.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. Terminal Description Terminal Color Function G Green Fan Rc RED Cooling transformer Rh RED Heating transformer O/B ORANGE Heat Pump O or Heat Pump B (reverse valve) Y/Y2 YELLOW Y, Y2: Use for 1-2 stages of conventional A/C or 1-2 stages of heat pump compressor W/W2 (AUX) White C W, W2: Use for 1-2 stages of conventional heat or Brown 1-2 stages of auxiliary heat with heat pump BLUE 24VAC common wire Note: 1.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. Wire Connection Procedure Please refer the following procedure to install your thermostat 1. Turn Off power Turn off the power to your heating and air conditioning system at your fuse box or flip the switch next to your furnace. In order to confirm the power is off, try to turn on heating or cooling by setting temperature on your old thermostat. 2. Remove old thermostat Remove face plate with screwdriver or by pushing the pressure latch. 3.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 1. Operation 1.1 Hub Outlook 1.2 Home Screen 1.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 1.4 Mode Menu 1.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 1.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 2. Wi-Fi Configuration 2.1 Connect the Web UI and Join local network 2.1.1 Power on the module and waiting for 1-3 minutes, then discover the network under network setting. The device default name will be Linkit_Smart_7688_xxxxxx , Here xx means the last 6 characters of Mac address on WiFi module 2.1.2 The connection was successful, open the browser, enter the URL:mylinkit. local/ (or 192.168.100.1); Default account root, password: 00001111 , 2.1.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 2.1.4 Click the “Network setting” to enter the Network setting interface, the default selection is AP mode and Do not need to enter any password, direct login and wait around 90 sec. 2.1.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. If you want to reset the Wi-Fi configuration , just press and hold the button around 10 sec.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 2.2 Firmware Upgrade • Using Web UI: (For Kernel Upgrade) 2.2.1 Sign in the Hub Web UI. Please see section 2.1 , “Connecting to the Web UI” 2.2.2 After you’ve signed in, click on the UPGRADE FIRMWARE . 2.2.3 Click Choose the file and select the file. Click UPGRADE & RESTART Selecting firmware file 2.2.4 The firmware will upload to Hub, please make sure the device stays connected to its power source until the firmware upgrade is completed. 2.2.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 3. Connect the system console with “putty” or “Terminal” 3.1 Using SSH (Secure Socket Shell) (1) Install PuTTY (2) Type mylinkit.local in Hst Name box, select SSH connection type Host name: mylinkit.local or IP address (3) Default account: root, password:00001111 (4) Open /root (5) Run ./start_all.sh 3.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. 2.shell A: stty -F /dev/ttyUSB1 speed 115200 cs8 -parenb -cstopb -echo 3.shell A:cat /dev/ttyUSB1 4.shell B:echo -e "AT\r\n" > /dev/ttyUSB1 5.you shall see the "OK" response of LTE module at shell A, then you can send your command on shell B. *Note UART tools is available with kernel 0.98 and hswapp #1.1.6 or later version MQTT Testing Connect to AWS using mqtt.fx, broker Settings Topics related to mqtt.
Copyright@Shenzhen Sun Wealth Technology Co, Ltd. FCC Statement 15.19 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 15.21 Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance.