Specification Sheet

Page 1 of 3
Power Configuration Form 11/2017
All 3-phase machines are rated at 208V. 60Hz. HSM requests that you have a 220V, 3 phase 60 Hz supply to help
compensate for a voltage drop if it occurs. (common in North America).
The 40VL requires a 50-amp line NEMA15-50P
The KP 80 & KP 88 require a 60-amp line NEMA15-60P
____ FA400.2 Conveyor shredders (stand-alone) require a 30 amp line. Plug supplied = NEMA L15-30P, 3 phase
with grounding. The plug comes out on the left and is approximately 6 feet in length.
____ FA490 Conveyor shredders (stand-alone) require a 50 amp line. Plug supplied = NEMA 15-50P, 3 phase with
grounding. The plug comes out on the right and is approximately 6-8 feet in length.
____ FA500.3 Conveyor shredders (stand-alone) require a 50 amp line. Plug supplied = NEMA 15-50P, 3 phase with
grounding. The plug comes out on the left rear and is approximately 14-16 feet in length.
____ 450.2 require a 20 amp line. Plug supplied = NEMA L15-20P, 3 phase with grounding.
The plug comes out on the left and is approximately 8-10 feet in length.
____ Profi-Pack 425 require a 20 amp line. Plug supplied = NEMA L15-20P, 3 phase with grounding.
____ HDS 150-1 Hard Drive require a 20 amp line. Plug supplied = NEMA L5-20, 120v, 1Phase with neutral
conductor. * Mobile units must request power requirements in advance.
____ HDS 150-2 Hard Drive require a 30 amp line. Plug supplied = NEMA L5-30, 120v, 1 Phase with neutral
conductor. * Mobile units must request power requirements in advance.
____ HDS 230-1 Hard Drive require a 30 amp line. Plug supplied = NEMA L15-30P, 3 phase with grounding.
____ HDS 230-2 Hard Drive require a 30 amp line. Plug supplied = NEMA L15-30P, 3 phase with grounding.
____ HDS 230-3 Hard Drive require a 30 amp line. Plug supplied = NEMA L15-30P, 3 phase with grounding.
____ PET Crusher 1049SA require a 20 amp line. Plug supplied = NEMA L15-20P, 3 phase with grounding.