Installation guide

Installation Instructions
OUTSIDE TOP EXHAUST (Vertical Duct)
INSTALLATION OVERVIEW
A1. Attach Mounting Plate to _Mfll
A2. Prepare Top Cabinet
A3. Check Damper Operation
A4. Mount Microwave Oven
A5. Ac!j ust Exha ust Adaptor
A6. (_onnect Ductwork
I-_ ATTACH THE MOUNTING
PLATE TO THE WALL
Remove the template fl'om the rear wall. The
mounting plate must be secured to the wall using at
least 3 toggle bolts and one wood screw. The wood
screw inust engage a wall stud.
_ Remove the toggle wings fl'om the bolts.
_ Insert the bolts into the mounting plate
through the holes designated to go into drywall
and reattach the toggle wings to '_A"onto each bolt.
To use toggle bolts:
Mounting
Plate
ml,
Spacingfor Toggles
MoreThanWall
-,,,-I_,-,.-!_,_Thickness
ToggleWings
B01tEnd
_ Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.
NOTE: Betore tightening the toggle bolts and the
wood screw(s), check again to be sure that the
mounting plate is level and centered leti to right.
CAUTION: Be careflfl to avoid pinching fingers
between the back of the mounting plate and the wall.
_ Tighten all bolts. Pull the plate away fl'om the
wall to hel I) tighten the bolts. Be careflfl not to
ove>torque the toggle bolts.
12