Owner's Manual

12
D.
Recirculating (non-vented ductless–
-1DQG51DQGRSWLRQDORQ-9
-9-9-9DQG-9PRGHOVRQO\
• Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
screw slots.
• Since the hood is to be recirculated (not to be vented
outside), do not cut out any vent openings in the wall
or cabinet bottom.
Installation Instructions
Wood shims
(recessed-bottom cabinets only–shims must be
DPLQLPXPRIs thick and cut to fit the width
of the inner recessed cabinet bottom)
Cabinet front
Center line
Electrical access
hole (in wall)
Hood mounting
screws (4)
Cabinet
bottom
10
3
ø4s (24s hood)
13
3
ø4s (30s hood)
16
3
ø4s (36s hood)
1
1
ø4s
1
ø2s
3
3
ø4s
5
1
ø4s
5
1
ø4s
7
3
ø4s
10
3
ø4s (24s hood)
13
3
ø4s (30s hood)
16
3
ø4s (36s hood)
C.
Outside rear exhaust
(Horizontal duct–3-1/4
s
x 10
s
Rectangular)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
RUN WIRES
Run the electrical wires through the wall or cabinet
according to National Electrical Code and applicable
local codes.
NOTE: DO NOT turn the power on until installation is
complete.
13
CUT HOLES
Cut holes at marked locations for duct and electrical
ZLULQJ)RUWKHYHUWLFDOGXFWFXWRXWsH[WUDWRZDUG
the front of the cabinet so you can move the duct
freely when installing the hood. It may also ease
installation by cutting the hole 10
1
ø2s instead of 10s.
12
MARK HOLES
Select the vent option that your installation will require
DQGSURFHHGWRWKDWVHFWLRQ
Hood mounting screws (4)
10
3
ø4s (24s hood)
13
3
ø4s (30s hood)
16
3
ø4s (36s hood)
10
3
ø4s (24s hood)
13
3
ø4s (30s hood)
16
3
ø4s (36s hood)
Cabinet front
Center
line
Electrical access hole
(in cabinet bottom)
Wood shims
(recessed-bottom
cabinets only–shims
must be a minimum
RIs thick and cut
to fit the width of
the inner recessed
cabinet bottom)
9
5
ø8s
1
3
ø8s
1
1
ø4s
7
3
ø4s
3
3
ø4s
1
ø2s
A.
Outside top exhaust
(Vertical duct–3-1/4
s
x 10
s
Rectangular)
• Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
B. Outside
top exhaust (Vertical duct–7s Round)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
10
3
ø4s (24s hood)
13
3
ø4s (30s hood)
16
3
ø4s (36s hood)
10
3
ø4s (24s hood)
13
3
ø4s (30s hood)
16
3
ø4s (36s hood)
Cabinet front
Center
line
Electrical access
hole
(in cabinet bottom)
Wood shims (recessed-
bottom cabinets only–shims
PXVWEHDPLQLPXPRIs
thick and cut to fit the width
of the inner recessed cabinet
bottom)
Access
hole for 7s
round duct
9
5
ø8s
1
3
ø8s
1
1
ø4s
7
3
ø4s
5
3
ø4s
Cabinet
bottom
11
5
1
ø4s
5
1
ø4s
Cabinet Bottom
Vertical duct
access hole
8s DIA.
HOLE
Horizontal duct
access hole