Specification

HTX26EASWWW
Hotpoint® 6.2 Cu. Ft. Capacity Electric Dryer with up to 120 Ft. Venting and Shallow Depth
DRYER DIMENSIONS (IN INCHES)
Specification Revised 2/24
EXHAUST OPTIONS: 4-way via rear, right, left and bottom.
CIRCUIT REQUIREMENTS: An individual, properly-grounded
branch circuit, protected by a 30-amp circuit breaker or
a time-delay fuse, is required.
ELECTRIC DRYER RATING: 240V, 5600W, 60Hz, 24 Amp,
208V, 4400W, 60Hz, 22 Amp
INSTALLATION INFORMATION: For complete information,
see installation instructions packed with product for current
dimensional data.
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet,
it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls
or other surfaces are: 0" either side, 1" front, top and rear.
- Closet doors must be louvered or otherwise ventilated and must
contain a minimum of 60 sq. in. of open area equally distributed.
If this closet contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area equally distributed.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the
absence of local codes, with the National Electric Code and
National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR
CLOSET INSTALLATION:
Minimum clearances to combustible surfaces: 0" both sides, 1" rear.
Listed by
Underwriters
Laboratories
22 3/8"
26 5/8"
3 7/8"
1 7/8"
3 1/8"
5"
37 1/2"
44"
27"
4 7/8"
POWER CORD 4 3/4"
11 3/4"
SIDE VIEW
REAR VIEW
*Order online at GEApplianceparts.com, 24 hours a day or by phone at 877.959.8688 during normal business hours.
For answers to your Monogram, Café™, GE Profile™ or GE Appliances product questions, visit our website
at geappliances.com or call GE Answer Center® Service, 800.626.2000.
POWER CORDS: GE Appliances strongly recommends the use of factory
specified parts. Select the power cord to fit your installaton requirements.*
NOTE: If the dryer circuit is on a circuit protected by a GFCI breaker, then
3-wire installation is not permitted. Hose wiring and dryer must be
configured for 4-wire.
Part Number
WX9X2
WX9X3
WX9X4
WX9X18
WX9X19
WX9X20
Type
3-Prong
3-Prong
3-Prong
4-Prong
4-Prong
4-Prong
Length
4 Feet
5 Feet
6 Feet
4 Feet
5 Feet
6 Feet
Amperage
30
30
30
30
30
30