Instruction manual

Mains frequency and voltage of the electric section and characteristics of the gas section
Model Gas section
Class
Rated power
kW (1)
II2H3+
8,00 (582 g/h - G30)
( g/h - G31)
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P. C.S. = 37,78 MJ/m3
GAS NOZZLE TABLE
GAS NOZZLE TABLEGAS NOZZLE TABLEGAS NOZZLE TABLEGAS NOZZLE TABLE
12
HDM67G8C2CX/UK
571
EN
Table 1 Liquid Gas Natural Gas
Burner
Diameter
(mm)
Thermal
Power
kW (p.c.s.*
)
Nominal
Reduce
d
By-Pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow*
g/h
***
**
Thermal Power
kW (p.c.s.*)
Nominal
Reduce
d
Nozzle
1/100
(mm)
Flow*
l/h
Triple Crown
(TC)
130
3.3 1.50
63 2x65
236 232
3.3 1.50
2x99
309
Semi Fast
(Medium)(S)
75
2.0 0.4
30 69
145 143
2.0 0.4
104
190
Auxiliary
(Small)(A)
55
1.0 0.4
30 50
73
71
1.0 0.4
78
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28
-30
37
20 25
35 45
20
17
25
Table 1 Liquid Gas Natural Gas Table 1 Liquid Gas Natural Gas
)
The front right hob burner injector should be used as the pressure test point.