Instruction for Use

15
CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and a light
switch to control cooking area lights.
Models with mechanical control panel
AHBS 9.4F AM X - A
HF 9.4F AM X - AHF 6.4F AM X
T1. ON/OFF light switch
T2. Speed 1/OFF switch
T3. 2-speed selection
T4. 3-speed selection
Models with Soft Button panel + LCD Display
AHBS 6.7F AL X - AHBS 9.7F AL
X
T1. Button ON/OFF suction motor
T2. Selection button for medium, high and intensive operating suction speed
(power).
Note: Intensive suction speed (power) intensiva (LED L1 flashing) lasts for
approximately 5 minutes, then the medium suction speed (power) is automatically
set.
T3. Selection button for ‘silent’ suction speed (power)
T4. Button ON/OFF lighting
L1. Status icon suction speeds (powers)
L2. St
atus icon saturation indicator for grease filter
L3. Status icon low (silent) suction speed (power)
L4. Status icon saturation indicator charcoal filter
L5. Status icon lighting
Reset filter saturation indicator
After perf
orming maintenance of the filter, press and hold button T3, the icon indicating
saturation will switch off. Repeat the operation if both icons indicating saturation
(grease and charcoal) are on.
Activation of the icon for c
harcoal filter saturation
The icon for charcoal filter saturation is normally disabled. To activate it, proceed
as follows:
With the hood off, press and hold for a long time and simultaneously T1 and T3:
L4 flashes at first then it switches on with steady light to indicate successful
activation.
Disabling the icon for charcoal filter saturation: repeat the above operation,
L4 switches on with steady light then flashes and in the end switches off to
indicate successful disabling.
Automatic operation at high temperature
Th
e hood is fitted with a sensor that detects the temperature. When this becomes too
high, the sensor automatically activates the medium suction speed (power). The hood
switches off when the temperature detected by the sensor has lowered significantly.
Models with Soft Button panel + Silent Speed
AHGC 9.7F AB X - AHC 9.7F AB X - AHC 9.7F LB X
T1. Button O
N/OFF suction motor
T2. Selection button operating suction speed (power)
Note: The intensive suction speed (power) (LED L3 flashing) lasts for
approximately 5 minutes, then the medium suction speed (power) is automatically
set (LED L2 on)
T3. Button ON/OFF lighting
T4. Selection button ‘silent’ suction speed (power)
L1. LED medium suction speed (power)
L2.
LED hi
gh suction speed (power)
L3 LED intensive suction speed (power) - timed (5 min.).
L4 LED filter saturation:
flashing: carry out maintenance of the charcoal filter;
on: carry out maintenance of grease filters.
L5 LED low (silent) suction speed (power)
L1+L2+L3 flashing in sequence: a
utom
atic operation at high temperature (see
related section)
Reset filter saturation
After carrying
out filter maintenance, press and hold button T1, LED L4 switches off.
Activation of the LED for char
coal filter s
aturation
The LED for charcoal filter saturation is normally disabled. To activate it, proceed
as follows:
With the hood off, press and hold for a long time and simultaneously T1 and T4:
L1 flashes first then L2 as well, to indicate successful activation.
Disabling the LED for charcoal filter saturation: repeat the above operation,
L1 and L2 start flashing first, then only L1, to indicate successful disabling.
Automatic operation at high temperature
Th
e hood is
fitted with a sensor that detects the temperature. When this becomes too
high, the sensor automatically activates the medium suction speed (power). The hood
switches off when the temperature detected by the sensor has lowered significantly.
Model with SOFT-TOUCH control panel
AHBS 9.7F LTI X - AHC 9.7F ATI X
To select hood functions, simply touch the controls:
T1. Button ON/OFF suction motor
T2. Button to
select medium suction speed (power)
T3. Button to select high and intensive suction speed (power)
Press once to select high suction speed (power) (LED L3 on);
Press again to select intensive suction speed (power) (LED L3 flashing).
Note: The intensive suction (power) speed lasts for approximately 5
minutes, then the high suction speed (power) is set automatically.
T4. Automatic shutdown button (Timer) and saturation indicator for charcoal
filter:
Automatic shutdown:
Press this button to set the automatic shutdown of the active suction speed
(power):
Silent suction speed (power): 20 minutes
Medium suction speed (power): 15 minutes
High suction speed (power): 10 minutes
Saturation indicator charcoal filter
When flashing, perform maintenance of the charcoal filter, if installed, then keep
the button T1 pressed for a long time to stop the flashing.
T5. Button to select ‘silent’ suction speed (power) and saturation indicator for
grease filter
Note: when flashing, perform maintenance of the grease filter; then keep the
button T1 pressed for a long time to stop the flashing.
T6. Button ON/OFF lighting
T2+T3+T4 flashing: autom
atic op
eration under high temperature conditions (see
relevant paragraph)
Activ
ation of the charcoal filter saturation indicator
This in
dicator is normally deactivated. To activate it, proceed as follows:
With the hood off, press and keep pressed simultaneously T2 and T3: T3 starts
flashing first, then T2 as well, to indicate successful activation.
Deactivation of charcoal filter saturation LED: repeat the operation described
above; T3 and T2 start flashing, then only T3 to indicate successful deactivation.
Automatic operation under high temperature conditions
The hood is equipped with a sensor which detects the temperature. When this
becomes too high, the sensor automatically turns on the medium suction speed
(power). The hood turns off as soon as the temperature detected by the sensor is
lowered significantly.