Product Manual Thank you for purchasing our product. Please read this manual before installation and use to ensure that your product will function at peak performance. Read this manual thoroughly and store in a safe place for future references.
IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING Warning To reduce the risk of burns, electrocution, fire, or injury to persons. 1. Close supervision is necessary when this product is used by, on, or near children or i invalids. 2. Use this product only for its intended use as described in this manual.
Danger Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded.
User Friendly Design New features to offer you an enjoyable experience LG slo ws siege) Gaea Parts Information + eco Overview Remote Control ~~ «=v roves Safety Information Warnings +c Attention -can Installation Before you Install Installing Your Product Function Explanations Maintenance Surface Cleaning Nozzle Maintenance Troubleshooting Power button ccs Wash functions « «pooh nnn Dryer Heated Seat Remote Control =~ vo Toilet Unit «cco navvy ens Specifications Parts Information Overview, Remote controller
HM Remote Controller Washingtonian JM Flushing JM Rear Washing XK Nozzle Position For posterior cleaning Flushing the toilet after use For women cleaning Adjust the nozzle Adjust the cleaning Position in five intensity of front and levels rear washing L learn a Switch between hot and cold water to wash ome @ =® NT Turn the Night Light ON/OFF \ Use for manually cleaning the nozzle By Drying off the washing area Stop Posterior Wash Stop Feminine Wash Stop Dryer 102/ Clare Adjust the water temperature ca a Adj
104f This product needs to be properly grounded. Risk of electric shock If unsure, contact an electrician. electrical installation company. Do not place a lit cigarette along with other burning objects into the unit. X Risk of fire. Do not touch, insert or pull out the power plug with a wet hand. Risk of electric shock. Do not use a power socket in poor condition or a damaged power plug. ¥Risk of fire and/or electric shock. Do not use during thunderstorms (pull out the power plug during storms).
@®Place the battery out of children and infant reach. fixity battery is swallowed, contact a doctor immediately. @If battery fluid leaks onto user, quickly rinse off area using water. @If battery fluid gets into eyes, do not rub your eyes. Quickly rinse it with water and consult a doctor immediately. 3 May result in vision impairment or blindness. When the battery is in use, do not do the following operations. @®Do not hold or store with metal objects (such as a necklace or a watch).
Jello] Before you Install Water pressure check, dimensional drawing Confirmation of water pressure @The minimum dynamic operating water pressure is 35 psi, and the maximum static water pressure is 108 psi. g E Open the angle valve for water supply. Ensuring a flow of water at least 5.28 GPM. Xf the above conditions cannot be met, the best flushing effect cannot be achieved and an additional booster pump is required to increase the pressure. (Tools: stopwatch, Water measuring bag.
4 Install the ceramic body, water supply hose 1.Place the wax ring on the drain hole at the bottom of the ceramic, 4 Attach the flush water hose to the [ valve and tighten, Clean water hose 2. Align the ceramic drain with the drain hole on the ground, and press down ta make the wax ring fully contact with the ground. 6 Connect the | valve to the water supply and tighten. Use gasket to prevent water leakage. 3 Fix the two sides of the ceramic with two bolts, and finally install the cap.
1.Connect to the grounding. 2 Plug In AC 120V power plug. 1.0pen the water supply angle valve to maximum as shown in the figure. (1) Check to ses if the power light Son (2) Once the power light is on, the toilet will run its initial diagnostic: lights will tum on, cleaning nozzle will extend, the motor will begin to run and water will run through the 2.Confirm various connecting parts are not system. Once the light is off, water leaking. the self-diagnostic is complete.
14f HM Auto flush When the seat sensor no loner detects a user, it will automatically flush. The toilet will only flush once. The warm air function is activated and a flush is performed. ¥ Rear / front wash is not available during flushing. HM Emergency Flushing When the product is not powered-on, short press the rotated switch button on the side of the product . It can achieve emergency flushing function. 3X|f the above operation does not work, you need to replace the battery or contact your local dealer.
Lid led T Maintenance Regular maintenance is required to ensure normal use ® Cut off the power and water supply before maintenance. © Direct water wash to the entire product is prohibited. & C1 H Maintenance of product surface and ceramics ® Wipe dust or stains with a soft wet cloth @® A wet soft brush, cloth or sponge may be used to clean the ceramic area % Do not use abrasive cleaning solutions, such as alcohol, hibachi, paint thinner, resole, benzene, gasoline, sic. /\ WARNING Do not spray water or deter
Foe Justifiable Troubleshooting Experiencing issues with your product? If the user should run into any issues, please consult the troubleshooting guide below. If problem persists, please contact a professional. Power button Fault Diagnoses Check whether the attaching plug is loose or not Please check the circuit Check whether the power is switching on or off (the power Press rotated switch for 3s, the power light is on.
2) 2 LET 120/ Specifications 120V~ 60Hz 1050W(When inlet water temp in 53°F) psi, ensuring a flow of water at least 5.28 GPM. 108psi (static state) Tom ado flush rough-in 12in Transient heating Off/about 93.2°F ~102.2°F (4 levels) Thermostat series, thermal fuse, flow detection device Off/about 95 °F ~131°F (4 levels) Above 4m/s (3 levels regulations) Bi metal thermostat series, thermal fuse Off/about 93.2 *F~1022°F (4 levels) Thermal fuse 748in{l) * * Two AAA Batteries One alkaline 9V Batteries App. 35.