Installation Instructions

1. Power supply mode
Powered by 2 AA batteries
After installing the battery, the backlight lights up in red, and the red light in the box lights up at
the same time. If there is no operation within 10 seconds, the two lights will be off at the same
time.
After the light is off, all operations (including entering the password and changing the
password/RFID) are suspended, and need to be restarted after activation.
After the light is off, pressing any button will light up the backlight and the red light in the cabinet
again.
2. set password
Step 1: Use the emergency key to open the box
Step 2: Press the reset button once, the backlight flashes red once (0.5 seconds), the buzzer
beeps once (0.5 seconds), and the internal lighting red light flashes (until the registration status is
exited). (Red light for non-low voltage, yellow light for low voltage)
Step 3: Enter the password (4-6 digits) within 6 seconds and press the reset button once:
If the password is matched correctly, the backlight is turned off twice (0.5 seconds each time, 0.5
seconds interval), and 2 beeps (0.5 seconds each time, 0.5 seconds interval), the password
setting is successful. (Red light for non-low voltage, yellow light for low voltage)
If the password exceeds 6 digits or is less than 4 digits, 3 buzzers (0.05 seconds each time, 0.05
seconds interval) will beep quickly, and the password setting fails, restart from step 2.
It enters sleep without any action within 6 seconds.
Note: Registering a new password will overwrite the old password.
3. Set up RFID
Step 1: Use the emergency key to open the box
Step 2: Press the reset button once, the backlight flashes red once (0.5 seconds), and the buzzer
beeps once (0.5 seconds); the internal lighting red light flashes (until the registration status is
exited). (Red light for non-low voltage, yellow light for low voltage)
Step 3: Register an RFID within 6 seconds:
The backlight is turned off twice (0.5 seconds each time, 0.5 seconds interval), 2 buzzers (0.5
seconds each time, 0.5 seconds interval), RFID registration is successful. (Red light for non-low
voltage, yellow light for low voltage)
3 beeps (0.05 seconds each time, 0.05 seconds interval), RFID registration fails (including
configured and configured full), restart from step 2.
It enters sleep without any action within 6 seconds.
Note: Each device can store 5 groups of RFID. After the 5 groups have been stored, the 5 groups
of RFID that have been registered before need to be cleared.
three. Reset RFID
Clear RFID operation: press the reset button for 3 seconds (without any feedback in the first