Specifications

Thermostatic Radiator Valves and Actuators
264 customer.honeywell.com 70-6910
V135 Thermostatic Mixing or Diverting Valves
Thermostatic Mixing or Diverting Valves for use in hydronic
heating systems as a three-way mixing or diverting valve; controls
loop temperature in radiant heating systems.
Includes plastic handle for manual operation.
Knurled ring on T100R control head for easy attachment to V135.
Application: Thermostatic mixing/diverting valve for use in hydronic
heating systems. Controls loop temperature in radiant heating
systems.
Materials (Body): Bronze
Differential Pressure Rating: 17 psi maximum
Pressure Ratings (Steam): 232 psi maximum (1601 kPa)
Temperature Rating: 248 F Maximum (120 C Maximum)
Collar Diameter: 1 3/16 in. (30 mm)
Used With: T100R
Replacement Parts:
0900661 Replacement cartridge for V135A 1 in. and 1 1/4 in. models
T100R Thermostatic Mixing or Diverting Valve Actuator
For use in hydronic heating systems with V135 Valves in a three-
way mixing or diverting application. Controls loop temperature in
radiant heating systems.
T100R Thermostatic Actuator includes strap-on-pipe sensor.
Knurled ring on T100R control head for easy attachment to V135.
Application: Three-way mixing and diverting applications in hydronic
heating systems requiring remote sensing
Used With Valve: V135
Collar Diameter: 1 3/16 in. (30 mm)
Replacement Parts:
0900661 Replacement cartridge for V135A 1 in. and 1 1/4 in. models
V135 Thermostatic Mixing or Diverting Valves Replacement
Cartridges
Product Number
Pipe Size
Body Pattern
Capacity
Connection
Type
Dimensions, Approximate
(inch) DN (Cv) (inch) (mm)
V135A1006 3/4 in. DN20 Three-way 3.7 Cv Sweat 2 9/16 in. x 5 1/8 in. 64 mm x 128 mm
V135A1014 1 in. DN25 Three-way 5.8 Cv Sweat 2 15/16 in. x 5 13/16 in. 74 mm x 148 mm
V135A1022 1 1/4 in. DN32 Three-way 5.8 Cv NPT 3 3/4 in. x 7 1/8 in. 95 mm x 180 mm
V135A1048 1 1/2 in. DN40 Three-way 11.7 Cv NPT 3 3/4 in. x 7 3/8 in. 95 mm x 188 mm
V135A1063 1 1/4 in. DN32 Three-way 5.8 Cv Sweat 3 3/8 in. x 6 3/8 in. 86 mm x 162 mm
Product
Number
Capillary Length Temperature Range
Setpoint
(Integral or Remote)(ft) (m) (F) (C)
T100R1004 6 ft. 8 in. 2 m 50 F to 122 F 10 C to 50 C Remote
T100R1012 6 ft. 8 in. 2 m 86 F to 158 F 30 C to 70 C Remote
Product Number Description Used With
V135A-12VE Replacement cartridge for V135A 1/2 in. and 3/4 in. models V135
V135A-1VE Replacement cartridge for V135A 1 in. and 1 1/4 in. models V135
V135A-11/2VE Replacement cartridge for V135A 1 1/2 in. and 2 in. models V135