Residential Gas Controls Quick Reference Guide

Follow us on Twitter:
@honeywellcpro
YouTube:
@honeywellcpro
Residential
Combustion
Gas Controls
Quick Reference Guide
63-9581G PR
June 2015
© 2015 Honeywell International Inc.
Automation and Control Solutions
In the U.S.:
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422-3992
In Canada:
Honeywell Limited
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
www.honeywell.com
Learn More
Call toll-free 1-800-328-5111,
e-mail info@honeywell.com or
visit www.customer.honeywell.com.
Residential Tech Support: 1-800-468-1502
Burner Boiler Support: 1-888-516-9282
Residential Zoning: 1-800-828-8367
Customer Service: 1-888-793-8193
Sales Support: 1-800-828-8367
Canadian Technical Support: 1-800-405-9835
Canada Customer Care: 1-800-565-6282
2014-2015
S9200U1000 Replaces These Integrated Furnace Controls
OEM Brand SKU
Amana/Goodman
10207704, 10207706, 10207714, 10207719, 102077-02, 102077-03,
102077-04, 102077-09, 102077-19, 1809913, 10207701, 10207702,
10207703, 10207710, B1809913, B18099-13
ICM
ICM280
ICP
1010806, 1380686, 1380698, 1380699, 1380-686, 1380-699
Lennox
X445901, 1214201
Nordyne
624591, 624557, 624564, 624628, 902378, 902696, 903106,
6245570, 6245640, 6246310, 624557-0, 624591A, 624591-A,
624591-B, 624591-C, 624591-D, 624628-0, 624631-0, 624631A,
624631-A, 624631-B, 710128A, CAR903106
Other Manufacturers
350486, 8068142, 8068561, 8068563, 10334901, 99958174,
99958175, X13120666010
Rheem/ Robert Shaw
62-24268-01, 62-24268-02, 62-24268-03, 695-200
Texas Instruments
41F-5, 61F3, 6DT-1, 6DT-2
Trane
CNT03740, CNT1309, CNT1616, CNT1848, CNT1849, CNT2181,
CNT2182, CNT2183, CNT2789, D340790P01, D341122P01,
D330927P01, D330930P01, D330934P01, D340035P01,
D340354P01, D340774P01, D341235P01
United Technologies
1012-83-9336AHSC1, 1012-83-9337A, 1012-83-9651B, 1012-925A,
1012-925B, 1012-925C, 1012933D, 1012-933D, 1012955A, 1012-955A
White-Rodgers
50A50-130, 50A50-131, 50A50-208, 50A50-210, 50A50-215,
50A50-216, 50A50-229, 50A50-240, 50A50-245, 50A50-298,
50A50-407, 50A50-472, 50A50-475, 50A55-245, 50A55-250,
50A55-288-05, 50A50-110, 50A50-111, 50A50-112, 50A50-113,
50A50-142, 50A50-143, 50A50-205, 50A50-206, 50A50-207,
50A50-209, 50A50-230, 50A50-241, 50A50-285, 50A50-286,
50A50-288, 50A50-295, 50A50-296, 50A50-405, 50A50-406,
50A50-408, 50A50-438, 50A50-471, 50A50-473, 50A50-474,
50A50-571, 50A55-120, 50A55-143, 50A55-241, 50A55-285,
50A55-286, 50A55-288, 50A55-438, 50A55-474, 50A55-571,
50A55-843, 50T35730, 50T35-730, 50T35743, 50T35-743
York
3101250000, 5253733900, 43101972100, 52537074000,
52537077000, 031.01234.000, 031-00662000, 031-01250-700,
031-01266-700, 031-01267-00, 331-09167-000, 431-01972-100,
31011140002, 031-00662, 031-00662, 031-00662-000,
031-00662-700, 031-01140-000, 031-01140-001, 031-01140-002,
031-01140-701, 031-01140-702, 031-01234-700, 031-01235-000,
031-01235-700, 031-01250-000, 031-01266-000, 031-01267-000,
031-01267-001, 031-01267-001A, 031-01284-000, 031-01933-000,
031-01972-000, 031-01973-000, 031-02166-000, 031-09166-000,
031-09167-000, 331-01933-000, 331-01972-200, CAR03101973000,
CAR33101972200, CAR50A55843, G951ADB1401, G951ADB1401C,
G951ADB-1401C, G951ADB1402, G951ADB-1402, G951AEB-1403,
P03101267001, P031-01267-001, PTH031011400-00
* Always refer to box label for most updated cross reference. For wiring harness and timing specifications see installation guide.
S9200U1000Glowfly
Universal Hot Surface Igniter
Q3200U Igniter Bracket Replacement Cross Reference
a
Manufacturer OEM #
Q3200U
Bracket
1
Manufacturer OEM #
Q3200U
Bracket
1
Manufacturer OEM #
Q3200U
Bracket
1
American Road Equip. 201W A Modine 5H76032A C Tempstar 1096048 D
Arco Air
1096048
D Mor-Flo
3200618 A
Trane
340039P01 A
1380680 511-330-193 B B138196P01 B
Armstrong Air 38322B001 A
Nordyne
105141000
A
B144676P01 A
Carrier/
Bryant/
Payne
LH33ZS001
B or E
2
632-0770 B144676P02 B
LH33ZS001A 632-0880 B340039P01 A
LH33ZS002
Norton/St Gobain
201
B
IGN23 A
LH33ZS002A 271 IGN26 B
LH33ZS003 201D
A
IGN30 B
LH33ZS003A 201K IGN34 A
LH33ZS004 201L Viessman 9302-094 A
Claire Bros.
C-238
A
201N
Wayne Home
Equip.
62821-001
A
C242 201R 62821-002
Coleman
1474-051
A
201W
Weil McLain
511-330-139
B1474-052 271N 511-330-190
Comfort Maker 1096048 D 271NM D 511-330-193
Detroit Radiant 201D A 271P
A
White LB 120-07549 A
DMO Ind. 20834 A 271W
White-Rodgers
767A-301 A
Dornback Furnace 271W A Raypak 600915 B 767A-303 F
Ducane 20015201 B Rheem 62-22441-01 A 767A-306
AEnero Tech 10399 A
Roberts Gordon
90434300 B 767A-311
Evcon
1474-051
A
90436600 A 767A-350
1474-052
Robertshaw
41-402 A 767A-353 F
Evcon Coleman 025-32625-000 B 41-403 B 767A-354 A
Goodman
B1401009 D 41-404 B 767A-357 F
B1401018 C 41-405 A 767A-361
AB1401018S D 41-407 B 767A-364
HB Smith 50018 A 41-408 A 767A-366
Heil 1096048 D 41-409 B 767A-370 B
Hupp Industries 09050 A 41-410 A 767A-371 A
Intercity
1009604
D
41-412 D 767A-372 A
1096048 41-418 C 767A-373 D
Majestic
75-92-104
A
Snyder General
1380654
B
767A-376 B
75-92-105 1380672 767A-377 A
Metzger
201N
A
1380680 767A-382 B
201W Superior Fireplace 94851 A Williamson 9050 A
Yo r k
025-27766-000
A
025-27774-000
025-29043-000
025-29050-000
1
Table data is correct to the best of Honeywell’s knowledge as of this publication’s date. However, some
appliances may have igniter applications that are beyond the capabilities of this kit.
2
For igniters that require bracket A, use the template (Fig. 2 on page 3) to determine the tab to be removed.
3
For Carrier sealed combustion furnaces, you must use bracket E and retain the existing orange gasket for
use with bracket E.
Thermocouple
Selector Guide
Specifications Cross-Reference
Lead Length (in.) Universal Tradeline White-Rodgers Robertshaw Husky Johnson Controls
18 Q340A1066/U Q390A1095/U H06E-518 1970-18, 1980-18 K16BT-18 K19AT-18
24 Q340A1074/U Q390A1046/U H06E-524 1970-24, 1980-24 K16BT-24 K19AT-24
30 Q340A1082/U Q390A1053/U H06E-530 1970-30, 1980-30 K16BT-30 K19AT-30
36 Q340A1090/U Q390A1061/U H06E-536 1970-36, 1980-36 K16BT-36 K19AT-36
48 Q340A1108/U Q390A1103/U H06E-548 1970-48, 1980-48 K16BT-48 K19AT-48
Thermopile
Selector Guide
Lead Length (in.) Universal Direct Replacement Connection Includes
35 Q313U3000
Q313U3000 Spade Terminal
Push-In Clip, PG9 Adapter, 1/2" attaching
nut, Split nut, Spade to QC adapter
Q313A1022 Spade Terminal
Q313A1139 Spade Terminal Push-In Clip
Q313A1170 Spade Terminal PG9 Adapter
Q313A1188 Spade Terminal
Push-In Clip, 1/2" Attaching Nut, PG9
adapter
47 Q313A1055 Q313A1055 Spade Terminal 1/2" Attaching Nut
ST9120U Universal Electronic Fan Timer
ST9120U replaces over 44 existing models
ST9101A1006 ST9120C3018 ST9120G4038 ST9160B1001
ST9101A1014 ST9120C4008 ST9120U1003 ST9160B1019
ST9101A1022 ST9120C4016 ST9141A1002 ST9160B1027
ST9120A2004 ST9120C4040 ST9141A1028 ST9160B1035
ST9120B1005 ST9120C4057 ST9141B1001 ST9160B1043
ST9120C1012 ST9120C5005 ST9150A1003 ST9160B1050
ST9120C1020 ST9120C5013 ST9150B2000 ST9160B1068
ST9120C2002 ST9120D3009 ST9150B2018 ST9160B1076
ST9120C2010 ST9120G2024 ST9150B2026 ST9160B1084
ST9120C2028 ST9120G2032 ST9150B2034 ST9160C1000
ST9120C3000 ST9120G4004 ST9160A1002 ST9160C1018
Universal Ignition Module
Selector Guide/Cross Reference
Product
Number
Applications
Ignition
System
Flame
Senser
Ignition
Sequence
(Note 1)
S8910U3000
Line
Volt Hot
Surface
Ignition
1 or 2
Rods
P
S8610U3009
Intermittent
Pilot
1 or 2
Rods
C
Notes: 1. Ignition Sequence
C Continous retry.
P The number of trials for ignition and trial time is determined by the selection tab. If a
selection tab is not installed, the module will operate at four seconds trial time and one
ignition trial.
Timings
Ignition
Trials To
Lockout
(Note 1)
Ignition
Trial
Time
(Note 1)
Between
Trial
Time
(Note 1)
Pre-Purge
Flame
Failure
Response
Time
S8910U3000
1 or 3
Field
Selectable
4 or
7 Sec.
Field
Selectable
96 Sec.
3 Trial
Mode Only
32 Sec
or less
1.5 sec.
S8610U3009
C
15 Sec.
or 90 Sec.
Field
Selectable
5-minute
Delay After
Failed Trial
for Ignition
0 Sec. or S0
Sec. Field
Selectable
2.0 Sec.
Max
Cross-Reference
Honeywell White-Rodgers Robert-Shaw
Johnson
Controls
S8910U3000
S89C1004, S89C1012,
S89C1046, S89C1087,
S89C1103, S89D1002,
S89G1005, S89G1013,
S89G1021, S89G1047,
S89H1003, S89H1011,
S89H1029, S89J1008,
S890C1007, S890D1006,
S890G1003, S890G1011,
S890G1029, S890G1037,
S890H1002, S890H1010,
S890H1028
50E47-1 thru 50E47-79,
50E47-101 thru 50E47-179,
50E47-201 thru 50E47-279,
50E47-301 thru 50E47-379,
50F47-1 thru 50F47-79,
50F47-101 thru 50F47-179,
50F47-201 thru 50F47-279,
50F47-301 thru 50F47-379
HS780-17NL-104A,
HS780-17NL-108A,
HS780-17NL-304A,
HS780-17NL-308A,
HS780-17NR-104A,
HS780-17NR-306A,
HS780-17NR-308A,
HS780-34NL-108A,
HS780-34NL-304A,
HS780-34NL-306A,
HS780-34NL-308A,
HS780-34NL-312A,
HS780-34NR-104A,
HS780-34NR-306A,
HS780-34NR-308A,
HS780-34NR-312A,
HS780-34PL-308A,
780-910
S8610U3009
S86 Series ,S90 Series,
S8600 Series,
S8610 Series,
S8620 Series,
S8660 Series,
S8670 Series,
S8680 Series
50D49-350, 50D49-360,
50D49-361, 50D50-843,
50D-401
710-713, 715, 735-737,
780-002, 780-003,
780-701, 780-715,
780-735, 780-736,
780-737, 780-845,
SP710, SP715, SP720,
SP730, SP735,
SP750 Series
CSA42, 43,
44, 45, 46, 48,
49, G60, G65,
G67, G770
Series
Features and Functions
Type
of
Gas
Ignition
Source
Typical
Ignition
Hardware
Includes
S8910U3000
NAT
or LP
Switched
Mains
Norton 201,
Norton 271,
Hot surface
elements,
Q354
flame rod
S8610U3009
NAT
or LP
Internal
Q345, Q3451,
Q3452
Integral
Damper
Connector
Scan here for Glowfly
installation and product
information.