RTH7600 RET97C Series Touchscreen Programmable Thermostat Owner’s Manual Read and save these instructions. For help please visit yourhome.honeywell.com Installation is Easy 1. Label wires and remove your old thermostat 2. Install and wire your new thermostat 3. Set your new thermostat to match your heating/cooling system • This thermostat works with virtually all System Types • It is preset for the most common system Do you need assistance? We are here to help.
ATTENTION: MERCURY RECYCLING NOTICE Hg N O M E R C U RY N O B OT E MERCURIO This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash. For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at www.thermostat-recycle.org.
Table of contents Installation Programming and operation Setting the clock..................................14 Adjusting program schedules..............15 Overriding schedules temporarily.......15 Overriding schedules permanently.....16 Auto Changeover................................16 Change filter........................................17 Replace batteries................................18 Installation.............................................3 Advanced Installation..........................
2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached. If you have an older thermostat with a sealed mercury tube, turn to page 2 for proper disposal instructions. Do not remove wallplate yet Terminal designation C C MCR33823 3 Label Wires with Tags Label the wires using the supplied wire labels as you disconnect them, then remove the old wallplate. Wire color might not match labels.
Mount Wallplate Mount the new wallplate using the included screws and anchors. MCR28094 Drill 3/16-in. holes for drywall Drill 3/32-in. holes for plaster 6 Connect Wires Simply match wire labels. If labels do not match letters on the thermostat, check “Alternate Wiring (Conventional Systems)” on page 6 and connect to terminal as shown here (see notes, below). We are here to help. Call 1-800-468-1502 for wiring assistance.
Alternate Wiring (Conventional Systems) If labels do not match terminals, connect wires as shown here (see notes, below). RC Rc R R W W Y Y G G C C Y2 Y2 W2 2 2 3 W2 MCR28076 Remove metal jumper connecting R and Rc only if you must connect both R and Rc wires. If your old thermostat had both R and RH wires, remove metal jumper. Connect the R wire to the Rc terminal, and the RH wire to the R terminal. If your old thermostat had only 1 C or C1 wire, connect it to the C terminal.
Alternate Wiring (For Heat Pumps Only) 2 3 3 5 5 6 4 6 MCR28077 Leave metal jumper in place, connecting R & Rc terminals. If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If another wire is attached to the C terminal, stop now and contact a qualified contractor for help.
7 Install Batteries Install two AA alkaline batteries and remove tab. Remove tab Back of thermostat MCR28101 MCR27518 8 Install Thermostat onto Wallplate Install thermostat onto the wallplate on the wall. M28103 9 Turn Power Back On Turn the power back on to the heating/cooling system.
10 Set Time and Date 1. 2. 3. 4. Press Press Press Press s s s s or or or or 6 Go Back t t t t to to to to set set set set month, then press NEXT. day, then press NEXT. year, then press DONE. time, then press DONE to save and exit. 15 2012 Next 10:10 Done Done MCR33549 MCR33548 11 If your system type is...
Advanced Installation Enter System Setup 1. Press and release the left button. 2. Press and hold the center button until the screen changes (approximately 5 seconds). Mon 72 System Set To 6:30 PM 72 System Fan Auto Heat Off Cool Fan Auto Cool System & Fan Schedule Fan System Clock & Mode Done MCR33550 MCR33597 Changing Settings Function 1. Press the s or t button to change the setting. 2. Press NEXT to advance to next function. 3. Press DONE to save & exit.
Function Description Setting Press the s or t button to change the setting. 0170 Select System Type 1 Heat/cool: Gas, oil or electric heating with central air conditioning. 2 Heat pump: Heat pump without backup or auxiliary heat. 3 Heat only: Gas, oil or electric heat without central air conditioning. 4 Heat only with fan: Gas, oil or electric heat without central air conditioning. 5 Hot water heat only (no fan): Gas, oil or hot water heat without central air conditioning.
Function Description Setting Press the s or t button to change the setting. 0500 Furnace Filter Change Reminder 0 1 2 3 4 5 6 0530 Smart Response® Technology 1 On 0 Off 0600 Maximum Heat Setting 90°F (other options: 40-89°F [4-32°C]) 0610 Minimum Cool Setting 50°F (other options: 51-99°F [11-37°C]) 0640 Clock Format 1212-hour clock (i.e., “3:30 pm”) 2424-hour clock (i.e.
Thermostat controls Arrow keys Press to adjust temperature or to make selections from screen menus. Mon Set To 75 System Cool 6:01 Recovery System & Fan AM 75 Heat On Fan Auto Schedule Clock & Mode Clock & More Press to set clock or furnace filter reminder. M27525 System & Fan Schedule Press to select fan operation or system. Press to set program schedule (see pages 14–16).
Clock setting 1. To set the current time display, press CLOCK & MORE, then press s or t to adjust the time. Press and hold s or t to advance the time more quickly. 2. Press DONE to save & exit (or press GO BACK to exit without changing the time). System & Fan Schedule Clock & Mode M27527 MON 6:01 AM NOTE: The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores all date/time information.
To adjust program schedules 1. Press SCHEDULE, then EDIT to see weekdays. 2. Press SELECT DAY to highlight Mon-Fri (they will share the same settings). 3. Press NEXT STEP twice, then press s or t to set Wake time for selected days. 4. Press NEXT STEP, then s or t to set Heat temperature for this time period. 5. Press NEXT STEP, then s or t to set Cool temperature for this time period. 6. Repeat steps 3-5 to program other time periods (LEAVE, RETURN, SLEEP), then press DONE. 7.
Program schedule override (permanent) Press s or t to adjust temperature, then press HOLD. This will turn off the program schedule. Mon Temporary Set To 62 Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press USE SCHEDULE to cancel “Hold” and resume the program schedule. 6:08 System Heat AM 68 Fan Auto Permanent Hold Hold Cancel M27533 Auto changeover Use this feature in climates where both air conditioning and heating are used on the same day.
Filter reminder If activated during installation, the furnace filter reminder alerts you when it is time to replace your filter. Change Filter 70 Press RESET after changing the filter, to restart the timer. System Reset To reset the reminder interval before it expires: Set To 6:01 Heat AM 70 Heat On Fan Auto Schedule Clock & Mode M27535 1. Press MORE, then NEXT. 2. Press RESET. 3. Press DONE to save and exit.
Battery replacement Batteries are optional (to provide backup power) if your thermostat was wired to run on AC power when installed. Grasp thermostat and pull to remove from wallplate Install fresh batteries immediately when the LO BATT warning begins flashing. The warning flashes about 30 days before batteries are depleted. Even if the warning does not appear, you should replace batteries once a year, or before leaving home for more than a month.
Troubleshooting If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is blank • • • • Temperature settings do not change Make sure heating and cooling temperatures are set to acceptable ranges: • Heat: 40° to 90 °F (4.5° to 32 °C). • Cool: 50° to 99 °F (10° to 37 °C). Heating or • cooling system does not respond • • • • • Check circuit breaker and reset if necessary.
1-year limited warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
RTH7600 RET97C Series Termostato Programable Manual del propietario Lea y guarde estas instrucciones. Para obtener ayuda, visite yourhome.honeywell.com La instalación es fácil 1. Rotule los cabes y retire el termostato viejo 2. Instale y conecte los cables de su nuevo termostato 3.
ATENCIÓN: AVISO PARA EL RECICLAJE DEL MERCURIO Hg N O M E R C U RY N O B OT E MERCURIO Este producto no contiene mercurio. Sin embargo, este producto puede reemplazar uno que contenga mercurio. El mercurio y los productos que contengan mercurio no se deben desechar con los desperdicios domésticos. Para más información sobre cómo y dónde reciclar adecuadamente un termostato que contenga mercurio en los Estados Unidos, consulte con Thermostat Recycling Corporation en www.thermostat-recycle.org.
Acerca Instalación Programación y funcionamiento Configuración del reloj........................14 Ajuste de los cronogramas del programa.......................................15 Anulación temporal de los cronogramas.................................15 Anulación permanente de los cronogramas............................16 Conversión automática.......................16 Cambio del filtro..................................17 Reemplazo de la batería.....................18 Instalación.............................
2 Remueva su viejo termostato Retire el termostato existente pero deje la placa de montaje con los cables adheridos. Si el termostato existente tiene un tubo de mercurio No retirar la placa sellado, vaya a la página 2 para obtener instrucciones mural todavía sobre cómo desecharlo adecuadamente. Designación de los terminales C C MCR33823 3 Identifique los cables Identifique los cables a medida que los desconecta, utilizando las etiquetas que se suministran.
5 Coloque la placa de montaje Monte la nueva placa de montaje utilizando los tornillos y anclajes que se suministran. MCR28094 Taladre agujeros de 3/32 in. (2,4 mm) en yeso Taladre agujeros de 3/16 in. (4,8 mm) en paneles de yeso 6 Conecte los cables Simplemente haga corresponder las etiquetas de los cables.
Conexión alternativa (sistemas convencionales) Si las etiquetas no corresponden con los terminales, conecte los cables como se ilustra aquí (ver notas más abajo). RC Rc R R W W Y Y G G C C Y2 Y2 W2 2 2 3 W2 MSCR28076 Quite el empalme metálico que conecta R y RC solamente si usted debe conectar los alambres de R y de Rc. Si su viejo termóstato tenía R y RC los alambres, quite el empalme. Conecte el alambre de R con el terminal de Rc, y el alambre Rc con el terminal de R.
Conexión alternativa (pour thermopompes seulement) 2 3 3 5 5 6 4 6 MSCR28077 Deje el empalme en lugar, entre terminales de R y Rc. Si su viejo termóstato tenía alambres V y VR, ahora pare y entre en contacto con un contratista para la ayuda. Si su viejo termóstato tenía alambres separados de O y de B, una el alambre de B al terminal de C. Si otro alambre se une al terminal de C, ahora pare y entre en contacto con un contratista para la ayuda.
7 Instale las baterías Instale dos baterías alcalinas AA en la parte de atrás del termostato. Retire la lengüeta. MCR28101 Parte de atrás del termostato MCR27518 8 Instale el termostato en la placa de montaje Instale el termostato en la placa de montaje en la pared. M28103 9 Active nuevamente el suministro eléctrico Active nuevamente el suministro eléctrico del sistema de calefacción/aire acondicionado.
10 Ajuste de fecha y hora 1. 2. 3. 4. Oprima s o t para ajustar el mes, después oprima NEXT. Oprima s o t para ajustar la fecha, después oprima NEXT. Oprima s o t para ajustar el año, después oprima DONE. Oprima s o t para ajustar la hora, después oprima DONE para salir y guardar los ajustes. 6 Go Back 2012 Next 15 10:10 Done Done MCR33549 MCR33548 11 Si su tipo de sistema es...
Guía de instalación avanzada Ingrese la configuración del sistema 1. Presione y sostenga el botón izquierdo. 2. Presione y sostenga el botón central hasta que cambie la pantalla (aproximadamente 5 segundos). Mon 72 System Set To 6:30 PM 72 System Fan Auto Heat Off Cool Fan Auto Cool System & Fan Schedule Fan System Clock & Mode Done MCR33550 MCR33597 Cómo cambiar la configuración Función 1. Oprima s o t para cambiar los ajustes. 2. Oprima NEXT para seleccionar la función. 3.
Función Descripción Configuración Oprima s o t para cambiar los ajustes.
Función Descripción Configuración Oprima s o t para cambiar los ajustes.
Controles del termostato Ajuste de la temperatura Oprima para ajustar la temperatura, o para hacer selecciones de menús. Mon Set To 75 System Cool 6:01 Recovery System & Fan AM 75 Heat On Fan Auto Schedule Clock & Mode Clock & More Oprima para ajustar el reloj o recordatorio de cambio de filtro de la estufa. M27525 System & Fan Schedule Oprima para seleccionar el funcionamiento del ventilador o sistema Oprima para anular el horario de programa (ver páginas 14–16).
Configuración de la hora y el día 1. Para ajustar la hora actual en pantalla, oprima CLOCK, luego oprima s o t para ajustar la hora. Mantenga oprimido s o t para avanzar la hora con más rapidez. 2. Oprima DONE para guardar y salir (u oprima GO BACK para salir sin cambiar la hora). NOTA: El reloj de hora-real no debería requerir ajuste nunca ya que se actualiza automáticamente de acuerdo al horario de ahorro de energía diurno, y guarda toda la información de fecha/ hora.
Para ajustar los horarios de programas 1. Oprima SCHEDULE, luego oprima EDIT. System & Fan Schedule Clock & Mode 2. Oprima SELECT DAY para seleccionar M27527 Lun-Vier (compartirán los mismos ajustes). View Go Back Edit 3. Oprima NEXT STEP dos veces, luego oprima s o t para fijar la hora Wake. M27530 4. Oprima NEXT STEP, luego oprima s o t para fijar la temperatura Heat MON Period para este período. Set To TUE Wake 5.
Programación de la anulación del cronograma (permanente) Oprima s o t para ajustar temperatura, luego oprima HOLD. Esto apagará el horario de programas. Mon Temporary Set To 62 Cualquier temperatura que fije se mantendrá 24 horas al día, hasta que la cambie manualmente, u oprima USE SCHEDULE para cancelar “Hold” y reanude el horario de programas.
Cambio del filtro Si está activado durante la instalación, el recordatorio del filtro de la estufa le alerta cuando es hora de substituir su filtro. Change Filter 70 Oprima RESET después de cambiar el filtro, para recomenzar el contador de tiempo. System Reset Set To 6:01 Heat AM 70 Heat On Fan Auto Schedule Clock & Mode Para cambiar el intervalo del recordatorio: M27535 1. Oprima MORE, y después NEXT. 2. Oprima RESET. 3. Oprima DONE para guardar y salir.
Reemplazo de la batería Las baterías son opcionales (para brindar alimentación de respaldo) si el cableado de su termostato se instaló para funcionar con CA. Sujete el termostato y hale para separarlo de la placa de montaje Instale baterías nuevas inmediatamente cuando comience a titilar el aviso LO BATT. El aviso titila alrededor de 30 días antes de que las baterías estén agotadas. Aunque el aviso no aparezca, debe reemplazar las baterías una vez al año, o antes de dejar su hogar por más de un mes.
Localización y solución de problemas Si usted tiene dificultades con su termostato, pruebe las sugerencias que figuran a continuación. La mayoría de los problemas se pueden solucionar rápida y fácilmente. Pantalla en blanco • • El bombeo de calor emite aire frío en modo calefacción o aire caliente en modo refrigeración • Verifique el disyuntor y reinicie si es necesario. Asegúrese de que esté encendido el interruptor del sistema de calefacción y refrigeración.
Garantía limitada de 1 año Honeywell garantiza este producto, a excepción de la batería, por el término de un (1) año contra cualquier defecto de fabricación o de los materiales, a partir de la fecha de compra por parte del consumidor. Si en cualquier momento durante el período de garantía se verifica que el producto tiene un defecto o que funciona mal, Honeywell lo reparará o reemplazará (a elección de Honeywell).