USER MANUAL TRANSMISSION RISK AIR MONITOR
USER MANUAL FOR THE HONEYWELL TRANSMISSION RISK AIR MONITOR PACKING LIST Standard package includes Honeywell Transmission Risk Air Monitor (HTRAM) device User Manual X1 USB cable X1 X1 ADDITIONAL ACCESSORIES AVAILABLE • AC adapter: HTRAM-AD-USC (USC version), or HTRAM-AD-EU (EU version) or HTRAM-AD-UK (UK version) • Wall mount kit (separate instructions provided in kit) OPERATION 1. HTRAM is a desktop or wall-mounted device.
the device enters normal status and displays readings. When the device is in ON status, push and hold top button for 3 seconds to turn it OFF. USER INTERFACE SYMBOL Status LEDs Power button LCD screen Power input port FUNCTION Bluetooth™ icon Battery capacity level USB power input, icon will show on screen Low/Medium/High 400 CO₂ PPM Risk level based on multiple factors such as CO2, Temp, %RH and activity level etc.
Low Activity Setting Medium Activity Setting High Activity Setting 18 C 54%RH -- Custom Setting Temperature reading, °C or °F Humidity reading For the first use/power on, the device will initially show “- -” for approximately 1 minute QUICK START GUIDE Step 1. Make sure you have everything, then charge the device. • Make sure these components were in the box.
to a power adapter or computer.Keepplugged-inuntilfullycharged. • Make sure the working environment is supported by Bluetooth™ and wireless with Internet access, and a user-supplied smartphone using Apple iOS or Android™. Step 2. Power up the device, download the app and complete the setup: • Remove the protective film from the monitor display. • Turn on the Honeywell Transmission Risk Air Monitor by pressing and holding the “Start” button on the top for five seconds.
HOW TO REGISTER For individual users with less than 10 devices, we recommend going through the self-registration process via the mobile application. 1. Launch the mobile app, and click the“REGISTER” button and agree to the “Honeywell Data Privacy” notice. 2. Enter your email address and choose the region you are located in, then click to send the verification code. 3. Check your email for the verification code and enter it on the mobile app to finish the verification process. 4.
1. For North American enterprise users, please go to https://airmonitoring.honeywell.com; for EU enterprise users, please go to https://airmonitoring.eu.honeywell.com 2. Click the “REGISTER” button, and agree to the “Honeywell Data Privacy” notice. 3. Enter the sales order number and click “VERIFY ACCOUNT” to validate purchase of your devices. 4. Enter your email address and click to send the verification code. 5. Check your email for the verification code and enter it on the web portal, then click “NEXT”.
2. On the App, click the +Add New icon to add an air monitor device. 3. Click the Connect icon to pair with the device, the Bluetooth icon will blink. 4. Confirm the device is ready for pairing: See the icon blinking. Ensure the device's Bluetooth icon is blinking on the screen. 5. The app will pop up a window and request the user to input the PIN CODE shown on the device's screen. 6. If two or more devices' Bluetooth are activated, you can use the serial number to identify which device is to be paired.
10. If you are an enterprise user and your organization has secured WIFI® network, please reach out to your organization's IT personnel to configure the WIFl® settings for the device network. Monitors should be placed in the center of activity areas and should be close to breathing height (approximately 1.5 m, depending on the height or age of the room’s occupants), out of direct sunlight, and not directly located near induction units, floor fans, or heaters. In an organizational setting, e.g.
DEVICE INDICATION AND RECOMMENDED ACTIONS DEVICE INDICATION ¹ GREEN YELLOW RED Low Activity Setting² ³ <800ppm 0.043% infection risk 800ppm 0.043% infection risk 1100ppm 0.051% infection risk Medium Activity Setting² ⁴ <700ppm 3.40% infection risk 700ppm 3.40% infection risk 1000ppm 5.41% infection risk High Activity Setting² ⁵ <500ppm 7.32% infection risk 500ppm 7.32% infection risk 800ppm 25.
Recommended Actions Alarm - - Open windows - Turn on HVAC fan - Move out of room - Additional actions as needed - Ventilate room immediately - Reduce activities - Move out of room - Additional actions as needed - One beep Two beep 1. The HTRAM’s preset PPM measurements for each Activity Level are subjective standards based on Honeywell’s assessment of U.S.
4. Percent of infection risk calculation is based on the following assumptions and is only intended as guidance: Total number of people: 20, Infected: 1; Time duration: 45 mins and room size: 900sqft. 5. Percent of infection risk calculation is based on the following assumptions and is only intended as guidance: Total number of people: 20, Infected: 1; Time duration: 60 mins and room size: 900sqft. SCENARIO SELECTION The device has three pre-programmed scenario settings based on activity levels.
• Other general assumptions from risk estimator can be found in the below table: Parameters Value Unit Source Length of room 30 ft Width of room 30 ft Volume 900 sq ft Height 16 ft Pressure 0.95 atm Temperature 20 C Relative Humidity 50 % Background CO2 Outdoors 415 ppm Decay rate of the virus 0.62 h-1 default per:https://tinyurl.com/covid-estimator Deposition to surfaces 0.3 h-1 default per:https://tinyurl.
Quanta Concentration initial value 0.00 no virus at the beginning • The default setting is the low activity setting with the alarm threshold of 800 ppm for medium and 1100 ppm for high. DATA HISTORY 1. To review the device’s data history, please click the “Data History” tab on the mobile app. 2. You can switch among CO2, temperature, and humidity to view the device’s history. It can be viewed by day, week, or month. 3. The device’s maximum data storage is approximately 90 days.
DEVICE DEFAULT SETTINGS • Temperature unit: Select your regional temperature measurement unit on your mobile phone app and it will be displayed on the device screen as °C or °F. • Alarm sound: Users may enable or disable the device’s buzzer function. When the device’s alarm sound is enabled, the buzzer will beep at medium or high alarm. When the alarm is sound disabled, the buzzer will not beep when medium or high alarm is triggered. • Turn off display: users can turn off display on the mobile app.
Housing materials Aluminum alloy Display TFT Input voltage 5V Input current 1A Battery Lithium-ion rechargeable battery 10-hour battery time Battery capacity 2,600 mAh Operating temperature and humidity 0°C to 40°C, 0% RH to 90% RH USB port Micro USB * The Honeywell Transmission Risk Air Monitor (HTRAM) analyzes specific air quality conditions and alerts the user when conditions are present that may increase risk of potential exposure to airborne viral transmission.
required to prevent viral transmission. The HTRAM does not repel or destroy any microorganism, viruses, bacteria, or germs.
any kind, express or implied, and such information is accepted at buyer’s own risk and without any obligation or liability to Honeywell. • The information we supply in this data sheet is believed to be accurate and reliable as of this writing. However, specifications may change without notice, and Honeywell assumes no responsibility for its use. • The HTRAM does not detect for levels of CO2 that would make for an unsafe or unsuitable breathing environment.
• These warranties do not apply if the claimed defect or nonconformity is due to accident, misuse, neglect; or improper shipping or handling, installation, or testing; or any failure of electrical power, air conditioning, or humidity control. This warranty is valid only if the product has not been tampered with or serviced by any party not authorized by Honeywell.
• In case of non-conforming products, users may return such product to the distributor where they made the original purchase. • Honeywell shall not be responsible for any loss or damage of any form, including any accidental or necessary direct or indirect loss as a result of breach of any warranty or any other acts that damage the product. • These explicit warranties are the only warranties provided by Honeywell with respect to the product and are in lieu of all other warranties, express or implied.
• Customers wanting additional warranty beyond the standard one-year warranty offered by Honeywell have the option to purchase a 2-year extended warranty when purchasing the product. Any such extended warranty shall only extend the timeframe of the warranty terms above from three years from the date of purchase, and shall not provide any additional warranty or guarantee, express or implied. DISPOSAL This product contains a lithium-ion battery and aluminum alloy materials.
MANUFACTURER CERTIFICATE Honeywell Safety and Productivity Solutions certifies that the CO2 sensor in Honeywell Transmission Risk Air Monitor (HTRAM) device is maintenance-free in normal indoor environments. No calibration at end user is needed. The accuracy of the sensor is +/- 50ppm at 1000ppm CO2. SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Honeywell Safety and Productivity Solutions declare that the radio equipment type HTRAM-V2-W is in compliance with Directive 2014/53/EU.
Operating Frequency: 2400-2483.5 MHz (Bluetooth): <20 dBm EIRP; 2400-2483.5 MHz (WLAN IEEE 802.11b/g/n): <20 dBm EIRP. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
declare that the radio equipment type HTRAM-V2-W is in compliance with UK radio equipment regulation. The full text of the UK declaration of conformity is available at the following internet address: https://sps.honeywell.com/us/en/products/safety/gas-and-flame- detection/portables/honeywell-transmission-risk-air-monitor United Kingdom Contact: Life Safety Distribution GMBH. Address: Hatch Pond House, 4 Stinsford Road, Nuffield Industrial Estate, Poole, Dorset, BH17 0RZ, UK.
WARNING: TO PREVENT INJURY, DO NOT DISASSEMBLE,PUNCTURE, CRUSH, HEAT, OR BURN Use the authorized charger only. Never disassemble by yourself. Never short-circuit the battery. Dispose of the battery properly. Exposing the battery to an open flame could cause an explosion. 802.11 CAUTION Users are responsible for configuring the channels of operation that comply with their country regulatory standards. A Wireless Network Administrator should review the operationg restrictions for the access point.
ATTENTION • To better reflect the air environment, Honeywell recommends continuously monitoring indoor air using the HTRAM. It is recommended that the device runs for 24 hours for the first time until it is fully charged and initialized. • For safety and battery performance, the device can only charge the battery indoors in a 0°C to 40°C [32°F to 104°F] temperature range. The charging time from empty to full battery is approximately 6 hours.
For more information sps.honeywell.com Honeywell Safety and Productivity Solutions 9680 Old Bailes Road, Fort Mill, SC 29707 United States Contact us US: Tel. 800.430.5490 Fax. 800.322.1330 Canada: Tel. 888.212.7233 Fax. 888.667.8477 informationsp@honeywell.