Portable Evaporative Air Cooler User Manual Read and save these instructions before use COOL 0 3 1 ON 2 FF O FF ON O SWING Scan here: www.honeywellaircoolers.com www.jmatek.com E-mail: usinfo@jmatek.
PARTS DESCRIPTION 16 (1) 9 15 OFF 3 0 (2) ON 2 1 OFF ON SWING SPEED COOL (3) 14 17 10 (4) 13 8 (5) 11 6 12 1) Water Inlet Hole 2) Handle 3) Left Side Grill 4) Lever for Horizontal Louvers 5) Water Tank 6) Casters 7 7) Louvers 8) Water Level Indicator 9) Control Panel 10) Right Side Grill 11) Water Inlet Valve 12) Drain Plug 13) Rear Grill 14) Power Cord & Plug 15) Rear Grill Screws 16) Water Fill Door 17) Honeycomb Cooling Media (Media is on 3 sides) WARNING -- READ AND SAVE THE AIR
USE & OPERATION (CONTINUED) COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide. FILLING WITH WATER It is ideal to use the Continuous Water Supply Connection to run the unit for long periods of time without refilling the tank. This also helps prevent pump failure in case the cooler is running with inadequate water in the tank.
USE & OPERATION (CONTINUED) CLEANING & DRAINING THE WATER TANK (CONTINUED) t Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty. t Refill the water tank with clean water, up to the maximum level and drain it completely. t Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
TECHNICAL SPECIFICATIONS Model CO60PM Voltage 110 - 120 V Frequency 60 Hz Ampere 1.83 A Wattage 220 W Cooling Media Honeycomb Product Dimension 700 (W) x 466 (D) x 1017 (H) mm 27.6 (W) x 18.3 (D) x 40.0 (H) in 18.8 kg / 41. lbs Net Weight ELECTRICAL WIRING DIAGRAM For USA Outdoor Models Only. This appliance is equipped with a GFCI plug. Press the TEST button and then the RESET button once every month to ensure proper operation. Version: 110 - 120V/60Hz * Low water cut-off.
JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone: 1-800-474-2147 Email: usinfo@jmatek.com Web: www.jmatek.com © 2016 JMATEK Limited. All rights reserved. The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to these products. This product is manufactured by Airtek Int'l Corp. Ltd. (subsidiary of JMATEK Ltd.