Portable Evaporative Air Cooler Ideal for Indoor & Outdoor Use OWNER’S MANUAL Read and save these instructions before use ON F 3 2 OF 0 OFF 1 ON SWING D COOL SPEE Model: CO60PM Power rating: 220 Watts Voltage rating: 220 Volt AC, 50Hz Made in P.R.C.
QUICK START GUIDE Fill with water and plug into standard power outlet. Note : Please make sure that the power outlet is set to correct settings as per product specifications. Place near open door or window. (When used in Indoors) Note : Evaporative Air Coolers work on evaporative cooling mechanism which requires cross ventillation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX Read all instructions carefully before setting up and operating the unit, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION 1. 2. 3. 4. 5. 6. 7. 8. 9. PAGE THANK YOU .....................................................................................
THANK YOU! THANK YOU! Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling performance from your unit, fill the water tank with water & ice (if available) to increase its cooling power. COOLER LOCATION (IMPORTANT TO READ) (When used in Indoors) Place the cooler in front of an open door or window. Ensure thatthere is adequate cross ventillation in the room by leaving adoor or window open opposite from the cooler.
USER TIPS COOL ~ EFFICIENT ~ NATURAL Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake. This breeze drops the temperature and has a relaxing cooling effect. The evaporative air cooler cools the air by means of the evaporation of water. When water evaporates into the air, the result is a mixture of air and water molecules. This chemical change requires heat which is taken from the water molecules, resulting in cooler air propelled from the unit.
USER TIPS 0 ON 3 1 OFF 2 The recommended maximum relative humidity level is 60% orless, which allows a noticeable temperature decrease. Thetemperature decrease will be greater in drier climates becausehigher evaporation occurs when the humidity is low. OFF ON SWING COOL The evaporative air cooler should not be used in enclosedspaces. It must be kept level and there must be water in thewater tank. The room should have doors and windows openedto allow free air flow.
SAFETY RULES READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: 220 Volt AC 50Hz SHOCK HAZARD ON 0 3 1 FF 2 • Your cooler runs on 220 Volts, 50 Hz current. Check thehousehold voltage to ensure it matches the appliance's ratespecification. • Before operating the product remove it from its packagingand check it is in good condition. • DO NOT operate any product with a damaged cord or plug.
SAFETY RULES • DO NOT attempt to repair or adjust any electrical or mechanicalfunctions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation orexhaust opening as this may damage the product and couldcause an electrical shock or fire. • DO NOT operate with the Honeycomb media removed as thiswill overload and damage the motor.
PARTS DESCRIPTION 1 9 0 3 1 ON 2 FF O FF 2 ON O SWING COOL 14 3 10 13 8 11 12 1 2 3 4 5 6 7 Water / Ice Inlet Handle Left Honeycomb Panel Lever for Horizontal Louvers Water Tank Castors Wheels Horizontal Louvers 4 5 6 7 8 Water Level Indicator 9 Control Panel 10 Right Honeycomb Panel 11 Continuous Water Inlet 12 Water Drain Plug 13 Backside Honeycomb Panel 14 Power Cord & Plug 7
USE & OPERATION CONTROL PANEL OFF ON 0 3 OFF ON 2 1 COOL SPEED SWING NOTE: Speed control may be marked as High / Med / Low in certain units.
USE & OPERATION CONTROL KNOBS SPEED / ON - OFF Connect to the power supply and turn the Speed knob. The fan will start. Change the speed from 1 for Low to 2 for Medium to 3 High. To switch OFF the unit turn the Speed know to "0". 0 3 2 1 SPEED COOL To begin cooling the desired area press the ''COOL'' button. The indicator light will come on and the water pump will operate. You can feel the cooler air after the Honeycomb media is completely wet. SWING Press the ''SWING'' button.
USE & OPERATION INSTALLING HOSE ADAPTER NOTE : Continuous water supply connection is optional, and may not be provided with all models. Connect the garden hose Connector and turn on the water. Verify water tight connections by visually examining boththe float/hose connections. Water can be filled into the air cooler by: Continuous water supply With the help of garden hose connected to the hose connector on the unit, water will refill inside the tank on turning on the water tap.
CLEANING & MAINTENANCE WARNING • Before cleaning the unit, switch it to the ''off'' position and remove the plug from the power socket. • To clean the outside, use a damp cloth to remove dirt and dust. • Never use corrosive elements or any chemicals to clean this product. • When the product is not in use, store the unit in a dry place out of direct sunlight. CLEANING & DRAINING THE WATER TANK • Turn the power "off" and disconnect the unit from power supply.
CLEANING & MAINTENANCE MAINTAINING AND CHANGING THE HONEYCOMB • The appliance is supplied with Honeycomb cooling media. • The cleaning frequency for the Honeycomb media depends on local air and waterconditions. • • • In areas where the mineral content of water is high, mineral depositsmay build up on the honeycomb cooling media and restrict air flow. Draining thewater reservoir and refilling with fresh water at least once a week will help reduce mineral deposits.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch in ON. Power is not on. Try to turn the unit ON by changing the operation settings of manual knobs on the control panel. Pump is not turned ON. Turn on COOL function from control panel. Low or no water in tank, when COOL is selected. Refill water tank. Damaged Pump or Calciumdeposits on blower. Contact service centre. New Unit.
TECHNICAL SPECIFICATIONS MODEL NO.
ELECTRICAL WIRING DIAGRAM 15
: © 2012 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. Manufactured by AirTek International Corporation Limited.