Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use 0 3 OFF ON 2 OFF 1 ON COOL SPEED OWNER’S MANUAL SWING Read and save these instructions before use MAX Model: CO48PM MIN Power rating: 140 Watts Voltage rating: 120 Volt AC, 60Hz For product inquiries or support, visit www.honeywellaircoolers.com Customer Support : 1-800-474-2147 Made in P.R.C.
QUICK START GUIDE 1 Fill with water and plug into a standard power outlet. 2 Place near an open door or window. 3 Note: Please make sure the household power voltage matches the product specifications. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION 1. 2. 3. 4. 5. PAGE THANK YOU ................................................................................................
THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location (Important - Please Read!) Place the cooler in front of an open door or window. Ensure that there is adequate cross - ventilation in the room by leaving a door or window open opposite the cooler.
USER TIPS Energy Efficient, No Compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the honeycomb media. As the warm air passes through the media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently and inexpensively.
USER TIPS Indoor Use The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow.
SAFETY Read And Save These Instructions: When using electrical appliances, basic safety precautions should always be followed: 120V - 60 Hz Shock Hazard 0 3 OFF 1 ON COOL ON OFF 2 • Your cooler runs on 120 Volt AC, 60 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. • Before operating the product remove it from its packaging and check that it is in good condition. • DO NOT operate any product with a damaged cord or plug.
SAFETY • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. • DO NOT operate with the Honeycomb media removed as this will overload and damage the motor.
SAFETY • Don't use indoor extension cords outside. Look for extension cords specifically marked for outdoor use. Look for extension cords that have a GFCI (Ground Fault Circuit Interrupter) built in. • Make sure the amperage rating for the extension cord is higher than the amperage rating for the appliance. Check labels and owner's manuals on the appliance and the extension cord for amperage ratings. • Power cords have to be contained.
PARTS DESCRIPTION 0 3 1 ON 1 OFF 2 OFF COOL ON 9 16 SPEED SWING 15 2 13 3 14 4 10 MAX MIN 8 5 11 6 12 1 Water Inlet and Ice Loading Compartment 2 Handle 3 Left Honeycomb Panel 4 Lever for Horizontal Louvers 5 Water Tank 6 Casters 7 Horizontal Louvers 8 Water Level Indicator 8 7 9 Control Panel 10 Right Honeycomb Panel 11 Continuous Water Supply Connection 12 Drain Plug 13 Backside Honeycomb Panel 14 Power Cord & Plug 15 Rear Grill Removal Screws 16 Water Fill Door
USE & OPERATION Control Panel OFF ON 0 3 OFF ON 2 1 COOL SPEED SWING NOTE: Speed control may be marked as High / Med / Low in certain units.
USE & OPERATION Control Knobs Speed / On - Off Connect to the power supply and turn the Speed knob. The fan will start. Change the speed from 1 for Low to 2 for Medium to 3 High. To switch OFF the unit turn the Speed know to "0". Cool To begin cooling the desired area turn the "COOL" switch ON. The water pump will operate. You can feel the cooler air after the Honeycomb cooling media is completely wet. Swing Turn the "SWING" switch ON. The louvers will begin to move from right to left automatically.
USE & OPERATION CAUTION Unplug from power when refilling. Filling With Water Water can be filled into the air cooler by: Water Inlet (Manually) Water / Ice can be put into the tank through the top opening. There is a hole for water to flow into the tank. Continuous water supply (Auto Refill) Connect a garden hose to the continuous water supply inlet.
USE & OPERATION Filling With Water (Continuous Water Supply Connection) CAUTION Unplug from power source before filling This automated process eliminates the need to manually refill the water tank. • Securely connect the continuous water supply connector (located on the lower left side panel #11 on Page 8) to the water supply. • Turn on the water. • The water tank will refill automatically. • The water float valve will detect the water level and will automatically start or stop the water flow.
CLEANING & MAINTENANCE Important - Please Read! • The cooler is supplied with Honeycomb Cooling Media. • The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits.
CLEANING & MAINTENANCE Draning and Cleaning The Water Tank • • • • Turn the power “off” and disconnect the air cooler from the power supply. Move the unit to a location where it can be drained. Remove the drain plug and allow the tank to empty(#12 on Page 8). Refill the water tank up to the maximum level with clean water and drain it completely. • Fill water tank and rinse at least 2-3 times before use. Water Drain Plug • After cleaning ensure that the drain plug is back in place.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch is on. Power is not on. Turn the unit ON by pressing button on the control panel. Pump is not turned ON. On Control Panel, turn COOL FUNCTION to “ON”. Low or no water in tank, when COOL is selected. Refill water tank. Damaged Pump or Calcium deposits on blower. Contact service center. When the Cooler is new.
TECHNICAL SPECIFICATIONS MODEL NO. Voltage Frequency Wattage Ampere Water Tank Capacity Cooling Media Product Dimension (inches) Net Weight 16 CO48PM 120 V 60 Hz 140 Watts 1.83A 12.6 Gallon Honeycomb 24.40(L) X 14.76(W) X 34.17(H) 29.
ELECTRICAL WIRING DIAGRAM 17
SERVICE AND WARRANTY 1-YEAR LIMITED WARRANTY Read all the instructions before attempting to use this product. This 1 year limited warranty applies to repair or replacement product found to be defective in material or workmanship A. This warranty does not apply to any damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
SERVICE AND WARRANTY D. Please read the Instruction Manual carefully before setting up or using this product. If you believe this product to be suffering from a manufacturing fault, or if you have inquiries about this product, please contact our Customer Support: CUSTOMER SUPPORT JMA North America LLC Ramsey, New Jersey, 07446. Phone : 800-474-2147 Email : info@jmana.us When contacting our Customer Support, please have the information below along with the proof of purchase.
Distributor: JMA North America LLC Ramsey New Jersey 07446 Customer Support: 1-800-474-2147 E-mail: info@jmana.us www.honeywellaircoolers.com CO48PM_IM_Eng_Spa_USA(lowes)_7 November 2012 © 2012 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. Manufactured by AirTek International Corporation Limited.