Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C.
QUICK START GUIDE Fill with water and plug into a standard power outlet. Note: Please make sure the household power voltage matches the product specifications. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION PAGE THANK YOU .................................................................. ............................................
THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location (Important - Please Read!) Place the cooler in front of an open door or window. Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler.
USER TIPS Energy efficient, No compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the honeycomb media. As the warm air passes through the media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room.
USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow.
SAFETY READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: • Your cooler runs on 230 Volt AC, 50 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. • Before operating the product remove it from its packaging and check that it is in good condition. • DO NOT operate any product with a damaged cord or plug. We recommend not using an extension cord with this appliance.
SAFETY • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. • DO NOT operate with the Honeycomb media removed as this will overload and damage the motor.
PARTS DESCRIPTION 10 1 13 18 9 2 3 4 11 19 16 15 14 5 8 12 1 2 3 4 5 6 7 8 9 10 Control Panel Handle Louvers Left Side Panel Water Tank Power Cord Power Plug Casters Ice Compartment Lid Back Grill 17 11 12 13 14 15 16 17 18 19 6 7 Front Panel Water Level Indicator Remote Control Latch Right Side Panel Water Fill Door Drainage Tube / Cap Water Regulator Rear Grill Removal Screws ACCESSORIES: Remote Control ( Batteries not included) 7
USE & OPERATION CONTROL PANEL SWING SPEED COOL TIMER Icons on LCD Cool Swing Fan operating Time delay set Low speed Sleep Medium speed High speed 8 SLEEP
USE & OPERATION FUNCTION BUTTONS POWER Press the 'POWER' button to turn the unit ON. To turn the unit OFF, press the button again. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. FAN / SPEED Press the 'FAN OR SPEED' button repeatedly and the speed will change. The indicator light will show the selected speed. High Medium Low SPEED COOL COOL To begin cooling the desired area press the ''COOL’' button.
USE & OPERATION SWING LOUVERS MOVEMENT Press the ''SWING'' button. The indicator light will come on and the louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow. SLEEP When the SLEEP button is pressed, the cooler will run on HIGH speed for 1 hour, subsequently changing to MEDIUM speed for 1 hour followed by LOW speed for the remaining time.
USE & OPERATION ROOM COOLING AND HUMIDIFYING When the Water Regulator is set to ''MIN'', the water pump distributes minimal amount of water to the Honeycomb Media. This results in less water evaporation and reduces cooling effect. When the Water Regulator is set to ''MAX'', the water pump distributes the maximum amount of water to the Honeycomb Media. This results in maximum water evaporation and the cooling performance improves.
USE & OPERATION REMOTE CONTROL Power: Speed: Cool/Fan: Swing: Timer: Sleep : On / Off Low / Medium / High Controls cooling or fan option Controls the motion of the louvers Controls timer function for automatic shut off Turns on the sleep mode (Cooler runs on high speed for 1 hr followed by medium speed for 1 hr and then remains in low speed) POWER SPEED SWING TIMER COOL SLEEP Remote Control ( Batteries not included) NOTE • Open the battery compartment at the back of the remote control and insert tw
USE & OPERATION CAUTION Unplug from power when refilling. FILLING WATER Unplug the air cooler from power supply. Check water level indicator located on the front of the unit to determine the level of water inside the water tank. The water tank of this cooler holds up to 30 Litres of water. Be sure water in the tank is always above the minimum water level mark.
CLEANING & MAINTENANCE IMPORTANT • The cooler is supplied with Honeycomb Cooling Media. • The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits.
CLEANING & MAINTENANCE DRAINING AND CLEANING THE WATER TANK • • • • • • • • Turn the power “off” and disconnect the air cooler from the power supply. Move the unit to a location where it can be drained. Remove the cap from the water drain plug and allow the tank to empty (see parts description on page 7). Once the tank is empty, unlock the latches on both sides and lift off the cooler top section as shown in the figure and place it vertically on the floor.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch is on. Power is not on. Turn the unit ON by pressing buttons on the control panel. Pump is not turned ON. On Control Panel, Turn COOL FUNCTION to “ON”. Low or no water in tank, when COOL is selected. Refill water tank. Damaged Pump or Calcium deposits on blower. Contact service center. When the Cooler is new.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION The unit does not respond to remote control Remote control batteries. Check batteries, Replace if needed. Try to operate using the control panel. Damaged PCB. Try with remote control. If the unit responds, PCB board fasteners may be loose. Contact service center. If neither remote control nor control panel works, PCB board may be damaged. Contact service center.
TECHNICAL SPECIFICATIONS MODEL NO. CL30XC 230V 50Hz 250 Watts 25 Liters Honeycomb 458(L) x 352(W) x 856(H) mm 11.
: © 2012 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. Manufactured by AirTek International Corporation Limited.