Portable Evaporative Air Cooler for Indoor Use Evaporativo Portátil Enfriador De Aire para uso En El Interior Portatif Évaporatif Refroidisseur D'air pour Usage Intérieur OWNER’S MANUAL Read and save these instructions before use MANUAL DEL PROPIETARIO Lea y guarde estas instrucciones antes de usar la unidad MANUEL DU PROPRIÉTAIRE Lire et conserver ces instructions avant utilisation Model / Modelo / Modèle: CL201AE Power rating / Potencia / Puissance nominale: 250W Voltage rating / Tensión / Tensio
QUICK START GUIDE 1 2 3 Fill with water and plug into a standard power outlet. Note: Please make sure the household power voltage matches the product specifications. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.
INDEX Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION 1. 2. 3. 4. 5. PAGE THANK YOU.................................................................................................
THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location - Indoors (Important - Please Read!) Place the cooler in front of an open door or window. Ensure that there is adequate cross - ventilation in the room by leaving a door or window open opposite the cooler.
USER TIPS Energy Efficient, No Compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the Honeycomb Cooling Media. As the warm air passes through the Honeycomb Cooling Media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room.
USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow.
SAFETY READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: • Your cooler runs on 120 Volt AC, 60 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. • Before operating the product remove it from its packaging and check that it is in good condition. • DO NOT operate any product with a damaged cord or plug. We recommend not using an extension cord with this appliance.
SAFETY • DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. • DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. • DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause electrical shock or fire. • DO NOT operate with the Honeycomb Cooling Media removed as this will overload and damage the motor.
PARTS DESCRIPTION 1 8 2 12 13 14 3 4 5 9 10 6 15 11 16 7 1 Control Panel 2 Side Handle 3 Horizontal Louvers (Manual movement) 4 Left Side Panel 5 Front Cover Ornament 6 Power Cord & Plug 7 Casters 8 Ice Compartment Lid 9 Vertical Louvers (Automatic with SWING Button) 10 Front Panel 11 Water Level Indicator 12 Remote Control 13 Remote Control Holder 14 Right Side Panel 15 Water Fill Door 16 Drain Plug ACCESSORIES: Remote Control (2 AAA Batteries not included) 7
USE & OPERATION Control Panel Swing Control Power Button SWING POWER COOL HIGH MED Cool Button NATURAL 2hr SLEEP Mode Type Selector 4hr LOW SPEED NORMAL 8hr 1hr MODE TIMER Speed Control 8 Timer Control
USE & OPERATION Function Buttons POWER Press the POWER button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. To turn the unit off, press the button again. SPEED Press the SPEED button repeatedly and the speed will change. The indicator light will show the selected speed. POWER HIGH MED LOW HIGH MED LOW COOL To begin cooling the desired area, press the COOL button.
USE & OPERATION Function Buttons SWING Press the SWING button. The indicator light will come on and the louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow. SWING LOUVER MOVEMENT TIMER Press the TIMER button until the indicator light moves to your desired time. Once the set time has passed, the unit will automatically shut off. The Timer function allows you to program the unit for up to 8 hours of use.
USE & OPERATION Remote Control Power Speed Cool Swing Timer Mode : Turn the unit on and off : High / Medium / Low : Controls cooling or fan option : Controls the motion of the louvers : Lets you set the air cooler for auto-shut off from 1 to 8 hr settings : Switch between Normal, Natural & Sleep ON/OFF SWING MODE TIMER COOL SPEED Evaporative Air Cooler Remote Control (2 AAA Batteries not included) NOTE • Open the battery compartment at the back of the remote control and insert two new AAA dry cell b
USE & OPERATION Room Cooling and Humidifying When the Water Regulator is set to MIN, the water pump distributes a minimal amount of water to the Honeycomb Cooling Media. This results in less water evaporation and reduces the cooling effect. When the Water Regulator is set to MAX, the water pump distributes the maximum amount of water to the Honeycomb Cooling Media. This results in maximum water evaporation and the cooling performance improves.
USE & OPERATION CAUTION Unplug from power when refilling. Filling with Water Open the Water Fill Door located below the Remote Control Holder on the unit. The water tank of the unit holds up to 5.3 gallons of water. The Water Level display window is located on the front of the unit. Refill the water tank when water level is low. Do not fill water above the Max water level mark. Check water level in the tank before running the COOL function.
CLEANING & MAINTENANCE WARNING • Before cleaning the unit, switch it to the off position and remove the plug from the power socket. • To clean the outside, use a damp cloth to remove dirt and dust. • Never use detergents, corrosive elements or any chemicals to clean this product. • When the product is not in use, store the unit in a dry place out of direct sunlight. Cleaning & Draining the Water Tank • Turn the power OFF and disconnect the unit from power supply.
CLEANING & MAINTENANCE Cleaning the Carbon Dust Filter • Turn off the unit, and unplug the power cord from wall outlet. • Rotate the unit facing the back panel, and locate the knobs to remove the back grill. • Press both the knobs (see Fig. 1) and gently pull out the back grill, untill it is completely removed. • Now remove the carbon filter from the back panel. • You can now clean or replace the carbon filter. • Insert the cleaned or new dust-free filter back into place in the back panel.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch is ON. Power is not ON. Turn the unit ON by pressing button on the control panel or remote control. Pump is not turned ON. Turn on COOL function from remote or control panel. Low or no water in tank, when COOL is selected. Refill water tank. Damaged Pump or Calcium deposits on blower. Contact Customer Service Center. When the Cooler is new.
TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION The unit does not respond Remote control batteries. Check batteries. Replace if needed. Try to operate using the control panel. Damaged Control Panel on unit. Try to activate the unit with the Remote Control. If the unit responds, then the Control Panel on the unit may be experiencing problems contact the Customer Service Center. If neither the Remote Control or the Control Panel is working, contact the Customer Service Center.
TECHNICAL SPECIFICATIONS MODEL NO Voltage Frequency Ampere Wattage Water Tank Capacity Cooling Media Product Dimension (inch) Net Weight 18 CL201AE 120V 60Hz 2.2A 250W 5.3 Gallons Honeycomb 18.9(L)x14.6(W)x32.9(H) inch 23.
ELECTRICAL WIRING DIAGRAM COOL SWING PUMP M PLUG H MLN L N COOL CAPACITOR F/R PCB M 19