ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Programming Guide K5305-1PRV5 10/04 Rev.
TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control): A. POWER UP, then press [✱] and [#] at the same time, within 50 seconds of powering up (this method must be used if ✱98 was used to exit program mode). OR B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.
PROGRAMMING FORM Entries apply to the ADEMCO VISTA-15P/VISTA-15PSIA and ADEMCO VISTA-20P/VISTA-20PSIA controls, except entries shown in dashed boxes, which apply only to the VISTA-20P/VISTA-20PSIA (partition entries) and are not applicable to the VISTA-15P/VISTA-15PSIA. In addition, where noted, certain fields have special settings when used with the VISTA-20PSIA/VISTA-15PSIA (indicated by V20PSIA/V15PSIA with heavy borders and reverse type throughout for easy identification).
∗49 Split/Dual Reporting ∗66 Arm Away/Stay Rpt Code [0] 0 = Standard/backup reporting only (all to primary) Primary Phone No. 2nd Phone No. 1 = Alarms, Restore, Cancel Others 2 = All except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All 4 = All except Open/Close, Test All 5 = All All ∗50 Burglary Dialer Delay [0,0,0,0,0,0] Away Stay Part.
∗88 Program Mode Lockout Options ∗96, ∗97 Initialize/Reset Defaults [0] 0 = standard *98 installer code lockout (reentry only by [∗] + [#] within 50 seconds after power up) 1 = lockout [∗] + [#] reentry after *98 exit (reenter via installer code or downloader only) 2 = not used 3 = lockout local programming after *98 exit (reenter by downloader only) ∗89 Event Log Full Report Code [00] | This is a command, not a data field. See page 2. ∗98, *99 Exit Commands This is a command, not a data field.
MISCELLANEOUS SYSTEM FIELDS (*174-*181) KEYPAD OPTIONS *190-*196 ∗174 Clean Me Reporting Options NOTES: 1. Options for keypad address 16 are set by the factory and cannot be changed.) 2. Each keypad must be assigned a unique address. Keypads programmed with the same address will give unpredictable results. [0] (for ESL smoke detectors) 0 = disable; 1 = Clean Me signal reports; NOTE: If Clean Me is enabled, you must enter “3” in field ✱56 programming for zone 1 response time.
Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182*185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below.
*56 Zone Programming Menu Mode (press *56 while in Program mode) The Zone Programming Worksheet is on page 13. For each of the following prompts, make the desired entry, followed by the [∗] key to accept the entry. Refer to the Installation and Setup Guide for detailed explanations for each prompt. SET TO CONFIRM? XMIT TO confirm 0 = no; 1 = yes (See XMIT TO CONFIRM prompt later in this section.) We recommend that you confirm the programming of every transmitter.
Wireless Key Programming Templates (press the [D] key from *58 Menu mode Summary Screen) This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user number (see System Operation section, Assigning Attributes Command in the Installation Instructions). TEMPLATE ? ENTER START ZONE Enter desired template number 1–6 (see chart below), then press [∗] to continue. To exit the Template screen, press [#].
∗80 Menu Mode (continued) ∗79 Menu Mode (press ∗79 while in Programming mode) ENTER OUTPUT NO. The *79 Device Mapping Worksheet is on page 14. Enter the device output number (programmed in *79 Menu Mode) you want associated with this output. 01-16 = VISTA-20P output no.; 01-08 = VISTA-15P output no.; 17-18 = onboard triggers Press [∗] to continue. ENTER OUTPUT NO.
*82 Alpha Descriptor Programming (continued) ADDING CUSTOM WORDS (up to 10 words) 4. Repeat Step 3 to create the desired word(s). Each word can be a maximum of 10 characters (except custom message/partition descriptor word numbers 11, 12, and 13, which can be a maximum of 16 characters). 5. When the word is complete, press the [8] key to save the custom word(s) in the vocabulary list and return to the “CUSTOM WORD ?” display. 6. Repeat Steps 1–5 for other custom words to be entered.
Setting Schedules (Installer Code + [#] + [6] [4]) GROUP NUMBER ( for event 2 user access) ENTER SCHED NO. 1-8; [∗] to continue. VISTA-20P: 01-16 = end-user schedules; 17-32 = installer-only schedules VISTA-15P: 01-04 = end-user schedules; 05-08- = installer-only schedules [∗] to continue. To Quit, enter 00. PARTITION ( for events 3-7,10,12) 0 = all partitions; 1 = partition 1; 2 = partition 2; 3 = common [∗] to continue.
*56 ZONE PROGRAMMING WORKSHEET (VISTA-15P supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone 1 2 3 4 5 6 7 8 Zone NOTES: Zone Type: see chart on page 12; Report Code: enabled if any digit entered as 1st digit; Hardwire Type (zns 1-8): 0 = EOL 3 = ZD 1 = NC 4 = DB 2 = NO Input Type: 2 = AW (zones 9-48) 3 = RF (zones 9-48) 4 = UR (zones 9-48) 5 = BR (zones 49-64) NOTE: Zones 9-16 not available if zone doubling enabled. Response Time: 0 = 10msec 1 = 350msec 2 = 700msec 3 = 1.
*57 FUNCTION KEY WORKSHEET A Option Function P1 P2 B com P1 P2 C com P1 P2 Comments D com P1 P2 com 01 02 03 04 05 06 07 08 09 10 11 12 00 Paging Time Display Arm AWAY Arm STAY Arm NIGHT-STAY Step Arming Device Activation Device: Comm. Test Macro Key 1 Assign each macro key to only a single partition. † Macro Key 2 Assign each macro key to only a single partition. † Macro Key 3 Assign each macro key to only a single partition. † Macro Key 4 Assign each macro key to only a single partition.
✱80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. 2. For Powerline Carrier devices (plcd), field ✱27 must be programmed with a House Code. 3. Tampers of expansion units cannot be used to operate devices.
5 Eileen Way, Syosset, NY 11791 Copyright © 2003 Honeywell International Inc. www.honeywell.com/security CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER.