BELMAR 52” CEILING FAN MODELS #50198, 50199 Español p. 19 LISTED FOR WET LOCATION Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am - 6 pm, EST and Friday, 8 am - 5 pm, EST.
WELCOME TABLE OF CONTENTS PREPARATION Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . 2 Before beginning the assembly of this product, ensure that all parts are present. Compare all parts with the package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product. Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . .
PACKAGE CONTENTS Unpack your fan and check the contents. You should have the following items: 3 2 8 4 1. Blade (5) 2. Canopy 3. Mounting Bracket 4. Canopy Cover 5. Downrod 6. Motor Housing 7. Switch Housing 8. Yoke Cover 9. Blade Arm (5) 10. Loose parts bags containing (not shown): Mounting hardware, blade attachment hardware, electrical hardware, pull chains, wire connectors, etc.
SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate, or install the product. • Before you begin installing the fan, disconnect the power by removing fuses or turning off the circuit breakers. • Make sure that all electrical connections comply with local codes, ordinances, the National Electrical Code, and ANSI/NFPA 70-199. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring.
MOUNTING OPTIONS ! DANGER ! Fig. 1 Turn off the circuit breakers and the wall switch to the fan supply line leads. Failure to disconnect the power supply prior to installation may result in serious injury or death. 1. Your fan has 3 mounting options: • Standard (Fig. 1) • Angled (Fig. 2) • Closemount (Fig. 3) Note: The fans in figures 1 through 3 are not the actual fan in your package, they are representation of the 3 different mounting options. Fig.
MOUNTING BRACKET INSTALLATION 4. Loosen all mounting bracket screws. Remove the two mounting bracket screws and washers from the round holes of canopy. Set aside for later use. Detach mounting bracket from canopy (Fig. 4). Mounting Bracket Screw Fig. 4 Mounting Bracket Screws Washer Washer Canopy 5. Secure the mounting bracket to the outlet box using screws and washers provided with the outlet box (not included) (Fig. 5). Fig.
STANDARD OR ANGLE MOUNTING INSTRUCTIONS 6. Partially loosen the two set screws in the yoke at the top of the motor housing (Fig. 6). Fig. 6 Set Screws Fig. 7 7. Remove the downrod pin and downrod clip from the downrod (Fig. 7). Downrod Clip Downrod Pin Downrod Pin Downrod Clip Fig. 8 8. Thread the wires from the motor housing through the yoke cover, canopy, and out the top of the downrod (Fig. 8).
STANDARD OR ANGLE MOUNTING INSTRUCTIONS 9. Slide the downrod into the yoke of the motor housing, align the holes, and re-install the downrod pin and downrod clip. Then re-tighten the two set screws (Fig. 9). Fig. 9 Downrod Downrod Pin Downrod Pin Set Screw Downrod Clip 10. Depending on the length of downrod you use, you may need to cut the lead wires back to simplify the wiring.
STANDARD OR ANGLE MOUNTING INSTRUCTIONS 12. Install the downrod ball into the mounting bracket opening. Align the slot in the ball with the tab in the mounting bracket. The downrod should not rotate if installed correctly (Fig. 12). Fig.
CLOSEMOUNT INSTRUCTIONS 13. Remove the canopy cover from the bottom of the canopy (Fig. 13) Fig. 13 Helpful Hint: The downrod, hanging ball, and canopy cover are not used in this type of installation. Canopy Cover Canopy 14. Remove the three closemount screws and washers from the top of the motor housing. Align the canopy with the closemount screw holes in the top of the motor housing.
WIRING ! CAUTION ! a WARNING ! Fig. 16 Be sure outlet box is properly grounded or that a ground (green or bare) wire is present. Black (live) ! White (neutral) If house wires are different colors than referred to in the following step, stop immediately. A professional electrician is recommended to determine wiring. Incorrect wire connection can damage the receiver and could cause fire or injury. • Connect the Green wires from the fan and mounting bracket to the Bare/Green (ground) supply wire.
CANOPY INSTALLATION 17. Lift the canopy up so the partially installed mounting bracket screws are situated in the L-slots on each side of the canopy. Rotate the canopy clockwise and install the remaining mounting bracket screws and washers from Step 4 (Fig. 17). Mounting Bracket Screw Fig.
BLADE INSTALLATION 18. Remove the ten motor screws from underside of motor and save for blade arm attachment. Discard the plastic motor blocks but keep the screws (Fig. 18). Fig. 18 Motor Block Motor Screw Motor Block Motor Screw 19. Partially insert three blade screws along with spring washers and flat washers to attach the blade arm to the blade. Then, tighten each blade screw starting with the one in the middle. Repeat with remaining blades (Fig. 19). Fig.
FINAL INSTALLATION 21. Attach the pull chain extension to the fan pull chain (Fig. 21). Fig.
OPERATING INSTRUCTIONS 22. Use the fan reverse switch, located on the side of the switch housing, to optimize your fan for seasonal performance (Fig. 22). Fig. 22 Using a ceiling fan will allow you to raise your thermostat in the summer and lower your thermostat in the winter without sacrificing comfort. Important: The reverse switch must be set either completely up or down in order for the fan to function correctly. If the reverse switch is set in the middle position, the fan will not operate.
REPLACEMENT PARTS LIST For replacement parts, call the customer service department at 1-877-361-3883, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday. PIECE MODEL 50198 MODEL 50199 PART # PART # DESCRIPTION A Blade Arm 50198-A 50199-A B Blade 50198-B 50199-B C Loose parts bags containing (not shown): Mounting hardware, blade attachment hardware, electrical hardware, pull chains, wire connectors, etc.
TROUBLESHOOTING At least twice each year, lower the canopy to check the downrod assembly, and then tighten all screws on the fan. Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching the finish. Clean the blades with a lint-free cloth. You may occasionally apply a light coat of furniture polish to wood blades for added protection. Important: Shut off the main power supply before you begin any maintenance tasks. Do not use water or a damp cloth to clean the ceiling fan.
LIMITED LIFETIME WARRANTY Subject to the limitations set forth below, Hong Kong China Electric appliance Company (HKC) warrants the fan motor for this ceiling fan to be free from defects in workmanship and material for the life of the product.