DFD-100 User Manual DFD-100 Hypo-vigilance/ Fatigue Detector User Manual Ver. 1.9 Holux Technology Inc.
DFD-100 User Manual Safety Precaution • Due to different conditions and environments when using DFD-100, users must take note of the following information: 1. DFD-100 has passed rigorous test in detecting driver hypo-vigilance (HPV)/ fatigue. However wrong operation, external interference, or malfunction, may affect the results; users must bear the risk. 2. When installing the device, ensure correct installation position.
DFD-100 User Manual • Use the power adapter included with the package, using power adapters other than the one provided will result in malfunction and could prove dangerous. • About the power adapter: 1. Do not use the power adapter in a wet environment. When hands and feet are wet, do not touch the power adapter. 2. While using the power adaptor ensure that the area is well ventilated. Do not let paper or other material cover the power adaptor, as this will interfere with cooling.
DFD-100 User Manual supply the device. • Suggestion! The user manual should be put in the car to read any time.
DFD-100 User Manual Warranty Statement • This warranty applies to parts and services that are manufactured and sold through Holux Technology Inc. The warranty length is one year from date of purchase (starting from the date on the sales receipt). Under normal user operation, Holux Technology provides free repair services. • Holux Technology is not responsible for providing repairs or replacements of any software; Holux Technology does not provide any warranty service for third party software/hardware.
DFD-100 User Manual product user manual, using parts not made or sold by Holux Technology, or repairs done by anyone other than Holux Technology and authorized retail/service providers. 2. Expendable parts are not covered in the warranty. 3. Please contact your local Holux Technology authorized service provider to learn more about geographical limitations, proof of purchase requests, response time agreements, and other specific maintenance service requests.
DFD-100 User Manual Copyright Information No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any mean, without the express written permission of Holux Technology, Inc. Copyright, All Rights Reserved. Technical Support • If there are any questions regarding the use of this product, please log on to the website www.holux.com and see the FAQ.
DFD-100 User Manual Table of Contents Safety Precaution.....................................................ii Warranty Statement................................................. v Product Description ................................................2 Product Caution ..............................................4 Product Appearance ........................................5 Wearing and Activating the DFD-100......................8 Wearing the DFD-100 .....................................
DFD-100 User Manual Product Description According to published studies and test results, the driver’s vigilance level decreases (i.e. hypo-vigilance) due to long hours driving on highways. The DFD-100 is a driver hypo-vigilance(HPV)/ fatigue detector that detects driver’s heart rate change to determine the driver’s HPV/ fatigue . The DFD-100 issues a warning whenever the driver’s vigilance level drops below the set-up limit.
DFD-100 User Manual Attention The DFD-100 is an auxiliary driving safety device. When it emits a warning beep, it means the driver’s vigilance level is low due to fatigue . Driver fatigue is as dangerous as drunk driving so when this happens, you should move to the side of the road and stop driving for your own safety.
DFD-100 User Manual Product Caution Do not use the device when you drive on urban road. Do not over charge. Do not use the device when charging. Do not place the device under the windshield to solarization.
DFD-100 User Manual Product Appearance DFD-100 Unit Product Appearance Legend Item Part Name Function and Description ①. DFD-100 Unit To use the DFD-100, first secure the Fixer to the seat belt then attach the device to the Fixer via the T-Bar on the back. ②. T-Bar This connects the Fixer and the DFD-100. Insert the T-Bar into the T-Bar Mount and then push downwards to clip it securely in place. ③. Buzzer Warning beeps are sounded from here.
DFD-100 User Manual ④. Power LED Charging Status – the green LED will be turned on while charging. When fully charged the green light will go out. ※ Faces the right side of the driver during use ⑤. Power Switch Hold down for 3 seconds to switch the DFD-100 on or off. Once the device is switched on, it will beep once and glow green for 10 seconds to indicate that the device is now running automatically. ⑥.
DFD-100 User Manual Fixer Item Part Name Function and Description ⑧. Fixer The Fixer is used for fitting the DFD-100 to the seat belt. ⑨. T-Bar Mount This connects the Fixer and the DFD-100. Insert the T-Bar into the TBar Mount and then push downwards to click it into place.
DFD-100 User Manual Wearing and Activating the DFD-100 Wearing the DFD-100 Step 1. Attach the DFD-100 Fixer to the seat belt. The Fixer should be oriented with the wider end pointing up. And the convex of Fixer is faced to users. Step 2. Once the Fixer has been fitted to the seat belt, the driver should then put on the seat belt.
DFD-100 User Manual Step 3. Attach the DFD-100 unit to the Fixer. Attention: 1. The T-Bar on the back of the DFD-100 should be aimed at the wider end of the 2. -shaped hole. The driver should choose an appropriate -shaped hole of the T-Bar Mount for their body shape. Press the T-Bar into the wider end of the -shaped hole and gently rotate around and push downwards to secure it. Make sure that the trough on the T-Bar is clipped into the narrower end of the -9- -shaped hole.
DFD-100 User Manual Step 4. Confirm the positioning of the DFD-100. Attention: The front of the DFD-100 must be positioned at the center of the driver's chest with the buttons and light indicators facing upwards. The lower edge of the DFD-100 should be level with a point 2 finger-width up from the xiphoid process of the sternum (indicated spot ). ※ Because of body type differences, the detection location may slightly differ.
DFD-100 User Manual 3cm 3cm 2cm 2cm Step 5. Adjust the location of the fixer. Slide the fixer to adjust the position of the DFD-100.
DFD-100 User Manual Step 6. Once the DFD-100 is properly in place turn on the power switch. When the DFD-100 is in the right place, hold down the power switch for 3 seconds to turn on the power. Please wait 30 seconds~1minute for DFD-100 to detect the driver's heart signal. Two short beeping sounds indicate that the heart signal is successfully detected.
DFD-100 User Manual Attention Driving on flat stretches of highway during long journeys increases the risk of HPV/fatigue. This device is intended primarily to be used when the driver is on a highway to avoid accidents. Disable alarm function When DFD-100 emits audio alarms, you can choose to silence it by pressing down the power switch once. If you choose to silence it twice within one minute period, the previous data will be erased and DFD-100 will reset the detector function.
DFD-100 User Manual Unbuckle the seat belt Step 1. Sliding downwards the Fixer and DFD-100. Step 2. Unbuckle the seat belt; let the seat belt and DFD-100 smoothly slide back.
DFD-100 User Manual DFD-100 Warning signals Warning Sound and LED display The HPV/fatigue detected function is not enabled: Warning Sound- Status LED Power LED Beep Action Power switch Switch on Hold down 3 sec. — - - - (at 5 sec. interval) (at 5 sec. interval) - No heartbeat detected =1 short Beep; —=1 long Beep -=Green on 10 sec.
DFD-100 User Manual The HPV/fatigue detected function is enabled: Action Warning Sound- Beep Status LED Power LED Heartbeat detected after device was switched on. - - Heartbeat detected correctly - (at 2 sec. interval) - Driver is becoming fatigue.
DFD-100 User Manual Action Power switch Warning Status LED Power LED Sound- Beep Auto power off - - - User Power off Hold down 3 sec. - ─── - Low Power - Bad Signal quality - (at 30 sec.
DFD-100 User Manual Attention ※ If the driver's heartbeat signal is too faint for the DFD-100 to detect, the DFD-100 will switch off 1 minute after it loses the heartbeat signal. ※ Bad signal quality means the detected signal is abnormal within 30 seconds continuously, such as: shake body long time or wrong detected position.
DFD-100 User Manual Battery and Charging 1. Charging with the Cigarette Lighter The USB car charger can be used to connect the DFD-100 to the car's cigarette lighter for charging. ※ Do not use the device when charging.
DFD-100 User Manual 2. Charging with standard USB Connect the mini-USB transformer directly to a standard power socket to start charging.
DFD-100 User Manual FAQ 1. Why can’t I use DFD-100 when charging in the car? The accessory of DFD-100 is included a car charger for your convenience to charge in the car. Due to driving safety, avoid distractions and the accuracy of fatigue detection; do not use DFD-100 when charging in the car. 2. Does DFD-100 have an instable detection in the winter? The DFD-100 detects driver’s heart rate change to determine the driver’s fatigue level.
DFD-100 User Manual the fixer; it can slide back with seat belt.
DFD-100 User Manual Technical Specifications DFD-100 Fatigue - Accuracy 90% Detection - False alarm rate Less then 1% Dimensions 8.6 x 5.6 x 2.0 cm - 3.7 Volt, 770 mAh, rechargeable lithium battery Power - 8 hours of continuous usage (PCB version) - Charging time: 4 hours (Charge the battery for 8 hours before using this device for the first time.
DFD-100 User Manual compatibility of general industrial products. Certificate number: EN 55011: 2009+A1: 2010 EN 61000-3-2: 2006+A2: 2009 EN 61000-3-3: 2008 EN 60601-1-2: 2007 IEC 61000-4-2 Ed. 2.0: 2008 IEC 61000-4-3 Ed. 3.2: 2010 IEC 61000-4-4 Ed. 2.1: 2011 IEC 61000-4-5 Ed. 2.0: 2005 IEC 61000-4-6 Ed. 3.0: 2008 IEC 61000-4-8 Ed. 2.0: 2009 IEC 61000-4-11 Ed. 2.
DFD-100 User Manual DFD-100 + Bluetooth Fatigue Detection - Accuracy 90% Dimensions 8.6 x 5.6 x 2.0 cm - False alarm rate Less then 1% - 3.7 Volt, 770 mAh, rechargeable lithium battery Power (PCB version) - 8 hours of continuous usage - Charging time: 4 hours (Charge the battery for 8 hours before using this device for the first time.) Key 1 key for power/ reset switch I/O interface Mini USB for charging Profile: SPP Power: 3.
DFD-100 User Manual - Operating Temperature: -10°C to 60°C - Storage Temperature: -20% to 70% Environmental specifications - Charging Temperature: 0°C to 45°C - Humidity: 30 to 90% Complies with IEC61000 & JAP WEPE electromagnetic compatibility of general industrial products. Certificate number: EN 55011: 2009+A1: 2010 EN 61000-3-2: 2006+A2: 2009 EN 61000-3-3: 2008 EN 60601-1-2: 2007 IEC 61000-4-2 Ed. 2.0: 2008 IEC 61000-4-3 Ed. 3.2: 2010 IEC 61000-4-4 Ed. 2.1: 2011 IEC 61000-4-5 Ed. 2.
DFD-100 User Manual Bluetooth- class2 BT2.0 Module Sensitivity at 0.1%BER RF Transmit Power Frequency (GHz) 2.402 2.441 2.480 2.402 2.441 2.480 2.402 2.441 Initial Carrier Frequency 2.480 tolerance 20dB bandwidth for modulated carrier Drift (Five slots packet) Drift Rate △f1avg 2.402GHz 2.441GHz “Maximum Modulation” 2.480GHz △f2max 2.402GHz 2.441GHz “Minimum Modulation” 2.480GHz BT Spec.
Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.