CAMERA CONTROL UNIT CU-HD1500 OPERATING INSTRUCTIONS Please read these operating instructions carefully for proper operation, and keep them for future reference.
Note: The model and serial numbers of your product are important for you to keep for your convenience and protection. These numbers appear on the nameplate located on he bottom of the product. Please record these numbers in the spaces provided below, and retain this manual for future reference. Model No. Serial No.
SAFETY INSTRUCTIONS Carefully read all safety messages in this manual and safety Instructions on your equipment. Follow recommended precautions and safe operating practices. SAFETY ALERT SYMBOL ! This is the “Safety Alert Symbol.” This symbol is used to call your attention to items or operations that could be dangerous to you or other persons using this equipment. Read these messages and follow these instructions carefully.
IMPORTANT SAFETY INSTRUCTIONS 1. Read Instructions All the safety and operating instructions should be read before the product is operated. 2. Retain Instructions The safety and operating instructions should be retained for future reference. 3. Heed Warnings All warnings on the product and the operating instructions should be adhered to. 4. Follow Instructions All operating and use instructions should be followed. 5. Cleaning Unplug this product from the wall outlet before cleaning.
14. Lightning For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. This will prevent damage to the product due to lightning and power-line surges. 15. Overloading Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock. 16.
WICHTIGE SICHERHEITSANWEISUNGEN 1. Alle Anweisungen lesen. Vor Betrieb des Erzeugnisses sollten alle Sicherheits-und Bedienungsanleitungen gelesen werden. 2. Die Anweisungen aufbewahren. Die Sicherheits-und Bedienungsanleitungen sollten fünftigen Bezug aufbewahrt werden. 3. Warnungen beachten. Die Warnungen auf dem Erzeugnis und in den Bedienungsanleitungen solten beachtet werden. 4. Anweisungen befolgen. Alle Bedienungsanleitung-und Verwendungsanweisungen sollten befolgt werden. 5.
12. Erdung oder Polarisierung Dieses Erzeugnis ist mit einem Schutzkontaktstecker mit drei Leitern ausgerüstet, mit einem Erdungskontakt. Dieser Stecker paßt nur in ein schuko-Steckdose. Dies ist eine Sicherheitsmaßnahme. Wenn Sie den Stecker nicht in die Steckdose stecken können, so wenden Sie sich bitte an ihren Elektriker, damit er die veraltete Schuts des Schutzkontaktsteckers unwirksam. 13.
21. Ersatzteile Wenn Ersatzteile erforderlich sind, darauf achten, daß der Wartungstechniker nur die vom Hersteller festgelegten Ersatzteile oder Teile mit den gleichen Charakteristiken wie die ursprünglichen Teile verwendet. Unautorisierte Ersatzteile können Feuer, elektrischen Schlag oder sonstige Gefährdungen verursachen. 22.
MISES EN GARDE IMPORTANTES 1. Lire les instructions Lire toutes les instructions de sécurité et de fonctionnement avant de faire fonctionner l’appareil. 2. Conserver ces instructions Conserver les instructions de sécurité et de fonctionnement á des fins de référence ultérieure. 3. Tenir compte des avertissements Tous les avertissements qui figurent sur l’appareil et dans le mode d’emploi devront être respectés. 4. Observer les instructions Observer toutes les instructions de fonctionnement et d’utilisation.
objet placé dessus ou contre eux. Faire particuliérement attention aux fiches des cordons, á la proximité des prises, et á l’endroit oú ils ressortent de l’appareil. 14. Foudre Pour renforcer la protection de l’appareil pendant un orage, ou si l’on s’en éloigne ou qu’on reste longtemps sans l’utiliser, le débrancher de la source d’alimentation. Ceci permettra d’éviter tout dommage de l’appareil dú á la foudre et aux surtensions de ligne. 15.
IMPORTANT NOTICE For USA These products have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Contents Outline and features............................................................................................................................ 1 Warnings and cautions when using................................................................................................... 2 Facility names and functions.............................................................................................................. 4 System Configuration.............................................................
Outline and features The CU-HD1500 is a camera control unit (CCU) designed for the newly developed three times high speed camera SK-HD1500. The CU-HD1500 has significantly reduced power consumption and sophisticated function. The CU-HD1500 simultaneously provides both three times speed outputs (1080i/720p)and normal speed outputs (1080i/720p/SD) to offer a flexible system operation. Features ■ Three times smoothly slow-motion playback combined with video server.
Warnings and cautions when using Salt spray or corrosive gases. Strong electromagnetic fields (e.g., near TV or radio transmitters). Where exposed to rain. CAUTION Do not disassemble or modify The camera contains precision internal components. Do not open the cover or disturb switches and controls other than designated. There is risk of impaired performance and damage. When connecting and disconnecting cables, grasp the connector by the body, not the attached cable.
Warnings and cautions when using Hybrid Fiber Optical Camera Cable & Connector Handling CU-HD1500 camera is using the optical fiber cable & connector which is required special technique for handling. 1. Cable Connector & Receptacle (1) FCF (Fiber Cable Female) (2) FCFR (Female Receptacle) (3) 2. Maintenance tool & information FCM (Fiber Cable Male) (4)FCMR (Male Receptacle) Cleaning Stick (CANARE CLETOP 2.5/2.
Facility names and functions (Front) 11 4 1 2 3 31 6 7 8 9 10 5 12 1 CCU POWER switch CCU power on/off switch. 6 R TALLY LED 2 CCU POWER LED Lights at red tally input or when CALL signal is sent from camera. Lights when power is on. 3 CABLE CHECK LED OK: CAMERA POWER switch 7 G TALLY LED 4 Lights at green tally input. can be 8 CALL button operated. OPEN: Fiber cable not connected. SHORT: Excess current in fiber cable. Note: CAMERA POWER switch Press to call the camera.
Facility names and functions (Rear) 17 PROMPT connectors (BNC) 13 HIGH SPEED OUTPUT connectors (BNC) Input analog video signal for the prompter. The signal is sent to PROMPT out connector on CA-HF1500. Outputs 2 sets of three times high speed signals as LINK A, LINK B and LINK C. [1080i, 720p] 18 Genlock connectors (BNC) 14 HD SDI connectors (BNC) Input tri-level sync signal or black burst signal for genlock operation. Outputs two lines of digital serial HDTV video signals.
Facility names and functions (Rear & Front) 26 COMMUNICATION connector 31 Receiver Level LED (Front) The strength of the arriving light signal via fiber cable is indicated by position of lighting LED. Intercom and tally signals are input from external system. 27 WFM CONTROL connector This connector is used to select the display mode of the waveform monitor. 28 TRUNK connector Use for communication with TRUNK connector on CA-HF1500 via RS-422 interface.
System Configuration Attach the Camera adapter(CA-HF1500) to the Camera head(SK-HD1500). Then connect the camera control panel and setup control unit to the CU-HD1500. 1. AC power supply operation When the CU-HD1500 CCU POWER switch is set to ON, the optical fiber cable connection is checked automatically (it takes about 5 seconds), and then power can be supplied to the camera by pressing the CAMERA POWER button to enable a video output signal.
System Configuration 3.DC power supply operation By carrying out the external input of the camera side power supply, long-distance cable transmission becomes possible. Directions for operation are as follows. 1) Between CU-HD1500 (camera control unit) is connected with CA-HF1500 (camera adaptor) by a single mode fiber cable. 2) The power supply of CU-HD1500 is switched on. 3) The menu of CU-HD1500 is displayed. 4) "CABLE MODE" of a CU-FUNCTION menu is set as SINGLE.
System Configuration 9-inch Viewfinder VF-L9HD / VF-L90HD 5-inch Viewfinder VF-HD500 Viewfinder adaptor AT-951 Viewfinder adaptor AT-550 Microphone adaptor MH-1000 Viewfinder adaptor AT-90 2-inch Viewfinder VF-402 Camera head SK-HD1500 Viewfinder adaptor AT-500 Camera adaptor CA-HF1500 Fiber cable Camera control unit CU-HD1500 Portable Zoom Lens 9-inch Viewfinder VF-L9HD / VF-L90HD Large Box Lens Lens Mounter LM-B1000 Small Box Lens Tripod adaptor TA-Z3 Setup control unit SU-1000 Viewfinder ad
Function menu Function menu Connect the camera control panel (RU-1500) or the setup control unit (SU-1000) to the CU-HD1500 to display the function menus on PIX video output. The function menus include the CCU menu to adjust the CU-HD1500 and the camera menu to adjust a camera.
Function menu To display CCU menu, turn on color bars and then press FUNC button of the camera control panel. ■CU-FUNCTION ■OUTPUT SELECT BUZZER :ENABLE SDI AUDIO :OFF CCU ID : 1 CABLE MODE:HYBRID SYS FORMAT 1080i 59.94Hz HIGH SPEED : 1080i HD1[1/2] : 1080i HD/SD1[1/2] : 1080i HD/SD2[1/2] : 1080i WFM/PIX : 1080i TIME/DATE: '12.01.01 ACPEST[SD] : 16:9 ■RETURN SELECT RET.CH CH1 CH2 CH3 CH4 ■ASSIGNMENT DATE DISP :Y.M.D TIME DISP :ON YEAR :12 MONTH :01 DAY :01 HOUR :12 MINUTE :00 SET DATA SELECT RET.
Function menu CU-FUNCTION menu ■CU-FUNCTION Item BUZZER BUZZER :ENABLE SDI AUDIO :OFF CCU ID : 1 Setting ENABLE, Factory setting ENABLE DISABLE *CABLE MODE: HYBRID SYS FORMAT TIME/DATE: 1080i 59.94Hz '09.01.01 12:00 SDI AUDIO ON,OFF OFF Description Sets buzzer operation during call input. ENABLE : Buzzer sounds. DISABLE : Buzzer does not sound. Sets the embedded audio ON/OFF of the HD-SDI /SD-SDI output. CABLE MODE HYBRID HYBRID Select the mode of optical cable.
Function menu OUTPUT SELECT menu ■OUTPUT SELECT HIGH SPEED : 1080i HD1[1/2] : 1080i HD/SD1[1/2] : 1080i HD/SD2[1/2] : 1080i WFM/PIX : 1080i ASPECT [SD] : 16:9 Item HIGH SPEED Setting 1080i,720p Factory setting 1080i HD1[1/2] 1080i,720p, TRUNK VIDEO HD/SD1[1/2] 1080i,720p,SD 1080i HD/SD2[1/2] 1080i,720p, SD 1080i Assigns output signal of HD/SD[1/2] connector. WFM/PIX ASPECT[SD] 1080i,720p, SD 16:9, 4:3 1080i 16:9 Assigns output signal of WFM/PIX connectors.
Function menu MIC GAIN menu ■MIC GAIN MIC1 MIC2 :-60dB :-60dB Item MIC1 GAIN MIC2 GAIN Setting -10dB, -20dB, -30dB, -40dB,-50dB,-60dB, -70dB -10dB, -20dB, -30dB, -40dB,-50dB,-60dB, -70dB Factory setting -60dB Description Sets the sensitivity of the MIC1 line. -60dB Sets the sensitivity of the MIC2 line. MIC GAIN of camera can be controlled remotely when camera.is conncected. When “*” mark is displayed on the left of MIC1/2, MIC GAIN can not be controlled, because camera is not connected, etc.
Function menu SD DTL menu Item ■SD DTL SD DTL :ON H GAIN : 0 V GAIN : 0 H CRISP :-128 V CRISP :-128 DTL FREQ :5MHz LEVEL DEP :-128 LEL DEP SLP:-128 Setting Factory setting Description SD DTL OFF,ON ON Enable the detail effect specialized for H GAIN -128 to +127 0 Adjusts the horizontal detail level. V GAIN -128 to +127 0 Adjusts the vertical detail level. H CRISP -128 to +127 -128 SDTV. Adjusts the lower threshold level to enable horizontal detail in order not to emphasize noise.
Function menu ECC filter indication When the FILTER setting is ON, the ECC filter is displayed at the lower center of the screen. The display depends on the optical filter position. A.3200K ECC_FILTER Displays ECC filter information B.4300K with optical filter 1. C.5600K D.6300K E.
Cable check, Warning indication Cable check CU-HD1500 automatically checks the condition of optical cable, and shows the results on both PIX OUT screen and LED indicators on front panel at start-up. If any troubles are detected, the camera power might be forced to shut down for safety.
Backup battery replacement Backup battery replacement The backup battery is already mounted at the factory. If the time/date can not maintain accurate information, the alarm message “BACKUP BATT EMPTY” is shown on PIX OUT for about 6 seconds at start-up. In this case, the battery should be replaced, and the date and time should be adjusted at the TIME/DATE menu. WARNING Be sure to replace the battery with a type CR2032 lithium battery.
Service information Connector pin diagrams INTERCOM (5 pin XLR female:HA16PRH-5S) MIC OUT 1,2 (3 pin XLR female:HA16RM-3SE) Combined connector:5pin XLR male PUSH 5 1 4 2 Pin 1 2 3 4 5 3 Combined connector:5pin XLR male PUSH Signal TALK (C) TALK (H) RECEIVE (C) RECEIVE L (H) RECEIVE R(H) 2 1 3 Remote 1,2 (4 pin female:HR10A-7R-4S(73)) Combined connector: HR10A-7P-4P 4 3 1 2 Pin 1 2 3 4 Signal +12V output DATA input DATA output DATA ground TALLY OUT(9pin D-sub female:RDED-9S-LNA(4-40)(55))
Service information COMMUNICATION (25pin D-sub male:RDBD-25P-LNA(4-40)(55)) Combined connector: 25pin D-sub female 1 13 14 25 Plug Contact supply CCU mainframe Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Signal SYS2 SYS1 SYS0 PD OUT (C) PD OUT (H) PD SHIELD PD IN (C) PD IN (H) ENG OUT (C) ENG OUT (H) ENG SHIELD ENG IN (C) ENG IN (H) GND 2W : OUT/IN(C) 2W : OUT/IN(H) 2W 2W 2W 2W 2W : NC 2W : NC NC TALLY
Service information MIC REMOTE (15pin D-sub female: RDAD-15S-LNA(4-40)(55)) Combined connector: 15pin D-sub male 8 1 15 9 Plug CCU mainframe SW ON :Lo Pin Pin SW OFF:Hi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Signal +5V OUT (200mA max) TALLY GND G TALLY OUT R TALLY OUT MIC1 GAIN CTL2 MIC1 GAIN CTL1 MIC1 GAIN CTL0 MIC SEL1 GND NC MIC2 GAIN CTL2 MIC2 GAIN CTL1 MIC2 GAIN CTL0 MIC SEL2 MIC SEL Hi : Internal Control (Menu) Lo : External Control (MIC REMOTE connector)
Service information TRUNK(9pin D-sub male:RDED-9P-LNA(4-40)(55)) Combined connector: 9pin D-sub female Plug 1 5 6 → ← 9 → ← *RS-232C(OPTION) *RTS:Request To Send *CTS:Clear To Send CCU mainframe Pin 1 2 3 4 5 6 7 8 9 Pin 1 2 3 4 5 6 7 8 9 Signal NC RX_RS-422+ or (RS-232C) (IN) TX_RS-422+ or (RS-232C)(OUT) NC GND NC RX_RS422-(RTS (RS-232C)) TX_RS422-(CTS (RS-232C)) NC WFM CONTROL (15pin female:YKF42-8043N) Combined connector: 15pin D-sub male Plug 5 1 6 10 15 11 ← ← ← ← ← ← ← ← CCU mainframe
Service information Switch setting for AC power supply J (Japan) :AC 100V 50/60Hz U (U.S.A.) :AC 117V 60Hz E (Europe ):AC 230V 50Hz Procedure 1. Loose two screws and lift the front panel slightly, and then pull it open. 2. Set two switches to supplied AC power voltage according to the diagram.
Service information Intercom system setting CUH1200-MAIN SW3 –No.
Service information Video frame rate setting The CU-HD1500 is switchable for video frame rate between 59.94 Hz and 50 Hz. The setting method is offered by the dip switch SW3–No.1 on CUH1200-MAIN board. When the dip switch SW6–No.1 is turned ON, the video frame rate can be switched by the dip switch SW3–No.2. Dip switch setting on CUH1200-MAIN Board SW3 1 2 3 4 5 6 7 8 59.94 Hz (default) Enable (default)
Service information Network Settings The network IP address can be set by connecting a CROSSED RJ45 network cable (crossed-cable) or straight RJ45 cable with network hub between a PC and the CU-HD1500. The control software is provided by HITACHI. a. XPORT web server device installation NOTE: Microsoft .NET Framework 2.0 or greater must be installed on the PC beforehand b. Insert the downloaded software that file name “Di32DL_4.2.0.3_Web.
Service information 1.) Please set or change the TCP/IP protocol properties of the PC to “Obtain an IP address automatically” because the IP Address initialization of CU-HD1500 is an automatic acquisition mode. If the CCU has set IP address, the PC has to be set “Use the following IP address” then input the IP address, Subnet mask, and Default gateway. 2.) Connect the CU-HD1500 to the PC as shown in the above figure.
Service information If the IP Address of the CU-HD1500 is highlighted, and the "Home" button on the screen is clicked, the Network Settings are displayed on the right pane of the DeviceInstaller program. Note that only the IP Address can be changed on the Network Settings pane. When it is necessary to change the port number of the CCU, click on the “Serial Settings” under Channel 1 on the Network Settings pane. 4.
Service information When CU-HD1500 is changed to arbitrary [IP Address], [Subnet Mask], and [Default Gateway], and the address is retrieved, it is necessary to match IP Address of PC, Subnet Mask, and Default Gateway. (Enough operational administrative to IP Address etc.
External View CU-HD1500 External View (Unit: mm) 30
Specifications Camera Control Unit CU-HD1500 Power supply voltage (J) AC100V 50Hz/60Hz (CU-HD1500J) (U) AC117V 60Hz (CU-HD1500U) (E) AC230V 50Hz (CU-HD1500E) Power consumption 300W approx. (AC operation, including SK-HD1500 ,VF-402 ,CA-HF1500 and AUX POWER OUT 100VA) Ambient Temperature Operating:0℃ ~ +40℃ Storage:-20℃ ~ +60℃ Dimensions 433(W) 88(H) 347(D) mm Mass 10kg approx.
Specifications Output signals Camera Control Unit CU-HD1500 (OUTPUT) HIGH SPEED OUTPUT HD-SDI LINK A, LINK B, LINK C (1/2) (Embedded 2-Chnl audio available) ・1080i : SMPTE292M ・720p : SMPTE292M DIGITAL OUT HD-SDI HD1 (1/2) (Embedded 2-Chnl audio available) ・1080i : SMPTE292M ・720p : SMPTE292M DIGITAL OUT HD-SDI or SD-SDI selectable (Embedded 2-Chnl audio available) HD/SD1~HD/SD2 (1/2) ・1080i : SMPTE292M ・720p :SMPTE292M ・SD-SDI : SMPTE259M-C DIGITAL OUT HD-SDI or SD-SDI selectable WFM HD/SD3 (WFM) (Embedded
Specifications ■Accessories ・Remote control unit ・Setup control unit ■Standard Composition ・Camera Control Unit : CU-HD1500 1 ・Code Set(U/J) : WC0051(0234-0089A 2.5M) (8488057) 1 ・Code Set(E) : VM0306B;VM0303B 2.