Document Reference: MPD-1611291-A
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 2/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Table of Content 1 System Overview 9 2 Features Summary 13 3 EXACT-V2 Rack 39 1.1 1.2 General overview .......................................................................... 11 Block diagram .............................................................................. 12 2.1 Features Overview ........................................................................ 15 2.2 Input Stream Interfaces ...............................
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.5.8 Digital precorrection ...................................................................... 60 3.5.9 Power level measurement inputs and AGC ........................................ 61 3.5.10 Dry contacts ............................................................................... 61 3.6 Conformity with EC Directive ..........................................................
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Revision sheet Document Number Revision Date Version Comments MPD-1611291 A Nov 2016 S100 Document creation ATSC 1.0 Version (ATSC 3.0 Ready) MPD-1611291 B Feb 2017 S100 Revised Warning Content warning This document contains preliminary information about some of the products in the Hitachi-Comark family.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter About this manual Intended audience This user manual has been written for those who have to use, configure and install the product. Some chapters require some prerequisite knowledge in electronics and especially in broadcast technologies and standards. Product described The following products are described in this user manual: EXACT-V2 EXACT-V2-20dB Commercial references and available options Product ref.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Associated publications The reader of this document could improve their understanding of the product and its effective use by reading the following documents: [A1] [A2] [A3] [A4] ATSC standards A/53, A/54 http://www.atsc.org/standards.html DVB Measurements ETSI TR 101 290 v1.2.1 www.dvb.org ATSC Compliance A/64 http://www.atsc.org/standards.html SFN Network in ATSC A/111 http://www.atsc.org/standards.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 8/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 1 3/10/2017 System Overview MPD-1611291-A Page 9/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 10/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 1.1 General overview EXACT-V2 exciter has been especially designed to support, in addition to ATSC 1.0, the complex ATSC 3.0 modulation scheme, including Digital Adaptive Pre-correction (DAP) circuits and all required mechanisms to feed transmitters with flexible and highly secured input stream formats. This ready-to-use high-end 1RU exciter offers the bestin-class performance for broadcasters that want to launch ATSC 1.0 or ATSC 3.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 1.2 Block diagram The generic block diagram is described below: Figure 1: EXACT-V2 functional block diagram EXACT-V2 features two ASI/SMPTE input streams that can be processed in parallel for stream redundancy (Primary/Secondary). Four IP streaming (Gigabit) input/output ports are reserved for ATSC 3.0 mode.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2 3/10/2017 Features Summary MPD-1611291-A Page 13/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 14/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.1 Features Overview Input Stream Management ATSC 1.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter o Manual mute and programmable mute condition on LORS o RF maintain function on stream input loss Clock and synchronization signal management o External reference sources: 1PPS, 10MHz inputs o Onboard GPS (VX20-x0x2) o 10 MHz reference output o LORS management Measurement/Monitoring o ATSC1.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.2 Input Stream Interfaces 2.2.1 ASI/SMPTE Inputs The unit offers 2 ASI/SMPTE inputs compliant either with DVB-ASI ([D1] & [D2]) or with SMPTE 310M. They can be used either in single or redundant mode. 188 or 204 byte packets without RS coding and 204 byte packets with RS coding are supported when used in ASI mode. If 204 byte packets including RS coding are provided, then the RS error checking and correction are performed.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.3.1 TS CleverSwitch Control CleverSwitch is a flexible input redundancy management mechanism designed by Hitachi-Comark. It is enabled by default and can be manually disabled or enabled. Figure 2: TS CleverSwitch block diagram CleverSwitch is based on a programmable consecutive error threshold. Once it is reached, the stream selection switches automatically from the primary input to the secondary.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.3.2 Seamless Switching The switching (and switching back) performed by the TS CleverSwitch between the primary and the secondary stream is not expected to be seamless. However, if the exact same data stream is present on both inputs (Primary & Secondary) then the modulator performs seamless switching between inputs. Switching is made on a packet basis. 2.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.6 Digital Precorrection The digital pre-correction feature is available for both ATSC 1.0 and ATSC 3.0 signal waveforms.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter The use of adaptive precorrection is generally preferred not only in order to reach higher performance and efficiency, but also in order to save on technician time. However, when several RF signals are combined together (adjacent channels), the use of Linear DAP is not possible because the feedback signal is then a combined spectrum of several channels. In that case a manual Linear precorrection is needed.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.6.1 Digital Adaptive Precorrection The Digital Adaptive Precorrection (DAP) block is illustrated here below. Figure 6: DAP integration block diagram The DAP function is composed of Non-Linear and Linear Precorrection and a dedicated down-converter. The down-converter receives the signal feedback after the external amplifier (FBA_In) and after the RF filter (FBF_In).
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter • SINGLE DAP: The DAP process is manually started and is stopped either by a timer value (user configurable) or manually stopped. Figure 7: Single DAP mode operation • SURVEY DAP: In this mode, the DAP process is started as the Single DAP mode. Once the timer is reached, then the DAP process can be automatically restarted if a shoulder or MER deviation is detected (user configurable).
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter • CONTINUOUS DAP: The DAP works continuously until the user exits continuous mode. Figure 9: Continuous DAP mode operation 2.6.1.2 Linear Adaptive Precorrection The purpose of Linear precorrection is to correct the distortion in amplitude and in group delay of the output filter. The precorrector is based on a complex FIR filter which can correct up to 3dB (range -3dB to 3dB) in amplitude and up to 3µs (range 0 to 3µs) in group delay.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.6.2 Manual Digital Pre-correction In addition to digital adaptive precorrection, EXACT-V2 also performs manual linear precorrection. Using the “MANUAL EDIT” mode, both amplitude and phase corrections are performed over the full spectrum of the signal. For this purpose, a table of 32 points can be loaded in the modulator with the Set Linear Curves command.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Figure 10: Sharp Filter Profile menu 2.7 Output Processing The nominal output level of the main output “RF Out” is 0 dBm for the standard exciter and 20dBm for the exciter with optional preamp. An attenuation between 0 and 17 dB per increment of 0.1 dB can be set. In addition, an offset gain between -1 dB and + 1 dB per increment of 0.1 dB can be set. If needed, the output spectrum can be reversed.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter The “RF Maintain” feature consists in keeping an RF signal presence out of the modulator in order to allow a constant power at the modulator RF output during an input stream error (the function “RF Maintain on Input Stream Error” shall then be enabled). The overall objective is to avoid any RF signal interruption at the output of the modulator for protecting the amplifier.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter from 8dB to 20dB. The default value is 10 dB, meaning that a light crest factor reduction is performed. The following figures display the Crest Factor parameter impact on a signal: Crest Factor setting = 20dB (No reduction) Without any crest factor reduction, the PAPR is 14.4dB Crest Factor setting = 11dB After the adjustment, PAPR is 10.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.7.2.2 Crest Factor Optimization Parameter In order to allow the best amplifier efficiency a “Crest Factor Optimization” parameter has also been added. It is active when the crest factor reduction is enabled (value ≠ 0). For a given “Crest Factor”, the “Crest Factor Optimization” enhances the signal shoulders.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.7.2.3 Protection Clipping Parameter Since adaptive precorrection can produce power peaks at the modulator output, a “protection clipping” has been added at the output of the modulator. It will allow the user to protect the amplifier input by clipping the signal out from the modulator. Note: Protection Clipping = 20 means OFF Recommended value to start = 15dB (default value) 2.7.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter DAP mode activation In the Settings Tab, the DAP mode can be enabled under Outputs > Precorrections: Note: Enabling or disabling the DAP causes a reset of the non-linear curves. The user is then given the possibility to save the current curves, if needed. Non-Linear DAP launch The same protocol as the basic DAP applies (please refer to the previous chapter).
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.8 Clock and Synchronization The clock and synchronization function is responsible for synthesizing the required temporal signals and data rates. A high-stability 10 MHz OCXO provides the internal clock reference. However, if synchronization with other equipment is required, an external 10 MHz clock signal can be chosen as a reference together with external 1PPS.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter The figure below shows the entire VX20-x0x2 synchronization processing block (the on-board GPS being depicted as “GPS receiver”): Figure 13: VX20-x0x2 synchronization processing block Then, depending on the user’s setup, three cases can be considered: 1) Working with external GPS signal reference (using on-board GPS receiver): Figure 14: VX20-x0x2 clock synchronization - GPS signal In this case, the modulator processes the 1PPS due to
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2) Working with external 1PPS reference signal: Figure 15: VX20-x0x2 clock synchronization – external 1PPS signal In this case, the modulator directly uses the 1PPS available from the external source available on the 1PPS I/O interface. This 1PPS reference signal is used for both temporal synchronization and 10 MHz PLL locking.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2.8.2 Warm-up Time This part aims at describing the WARM-UP function which has been designed for compensating the start-up delay of the OCXO (for instance, in case of AC power loss). In order to be stable the internal temperature of the OCXO must be stabilized and equal to 85°C. However, this could take up to 5 minutes to obtain a stable 10MHz reference.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter The PLL_Unlocked status (Mute on SFN Not Ready) is used in order to maintain that the output signal is muted (please refer to the mute conditions in chapter RF output muting and RF maintain features.) In case of SFN application, an optional functionality “PPS auto resync” is available to allow resynchronization of the internal PPS (used as a reference time in SFN) when 10MHz clock control is locked.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 2. Mute behavior when: Mute on LORS is enabled Mute on Clock Not Synchro is enabled LORS TimeOut is not reached If the LORS TimeOut is not reached when the clock reference comes back, another timeout starts (fixed to 60 sec), after which the module will mute if the Clock Synchro is still not OK: Figure 18: Mute behavior – LORS TimeOut is not reached 2.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter - A VDC signal from an external power sensor from 0 to 5VDC The working mode is configurable using the WEB GUI. Depending on the mode selected, additional parameters will be needed, such as the coupler sample value or external sensor offset/slope factor, to ensure an accurate measurement. Please refer to you external device user manual.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3 3/10/2017 EXACT-V2 Rack MPD-1611291-A Page 39/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 40/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter The EXACT-V2 unit is a standard 1RU rackmount chassis. The dimensions are 9.8” x 19” x 1.75”. The modulator weight is 10 lbs. Figure 21: EXACT-V2 1RU 3.1 EXACT-V2 mechanics 3.1.1 Front panel layout Below is a depiction of the exciter’s front panel.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter A Control Ethernet port is also available on the front panel. 3.1.2 Rear Panel Layout Below is a depiction of the exciter’s rear panel. Figure 23: EXACT-V2 Rear panel overview The rear panel provides all the connectors needed for interconnection with the exciter. Please refer to the next section for a detailed description. 3.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter ASI Stream Output interface x1 Function: ASI Output General Standard: DVB-ASI Name: ASI_Out Connector: BNC Connector–impedance 75Ω Type: Output Performances Data Rate: ASI: 80 Mbps maxi.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter GPS Antenna input General Function: Name: Connector: Type: Performances Antenna Type: Antenna Voltage Antenna System Gain: Frequency x1 GPS antenna input GPS SMA Input Active 3.3 VDC 10 dB 1575.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 1PPS reference input/output General Function: Name: Connector: Type: Performances Signal : Level: x1 Time Reference in/out 1PPS BNC – 50 kΩ Configurable I/O 1 PPS LVTTL / TTL (input) LVTTL (output) ±50ns (input tolerance) Figure 31: 1PPS reference input/output x1 General Performances Function: Standards: Name: Connector: Type: Frequency*: RF output ATSC 1.0 & ATSC 3.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter RF Output (with OPT-20dB Internal Preamplifier) General Performances X 1 Function: Standards: Name: Connector: Type: Frequency*: RF output ATSC 1.0 & ATSC 3.0 RF N connector – 50 Ω Output Bandwidth: Level: 6 MHz +20 dBm ATSC 1.0: EVM: Shoulders: Spurious: < 2.5% equalizer off 57 dB / 63 dB with precor < -50dBc ATSC 3.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Monitoring Output General Function: Standards: Name: Connector: Type: Performances Frequency: Level: Other: Monitoring Output (with OPT20dB internal preamplifer) General Function: Standards: Name: Connector: Type: Performances Frequency: Level: Other: x1 Monitoring output ATSC Monit Out SMA – 50 Ω Output See RF Output -20 dB (relative to RFout) x1 Monitoring output ATSC 1.0 / ATSC 3.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter RF Feedback Inputs General Function: Performances Bandwidth: Level: x2 RF Feedback inputs / RF Measurements FBA / FBF SMA – 50 Ω Input UHF, VHF or VHF B3 depending on model 75 MHz -5 to -15 dBm Max input level: +5dBm (before damage) Return loss: >13dB Standards: Name: Connector: Type: Frequency: Figure 34: Feedback inputs Forward Power Measure Input/AGC General Function: Standards: Name: Connector: Type: Performances Frequency:
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Reflected Power Measure Input General Function: Standards: Name: Connector: Type: Performances Frequency: (RF input) Range: Performances (VDC input) x1 Reflected Power Measure RFP In SMA – 50 Ω / High impedance Input Depends on model 0 to -10dBm Precision: 0.5dB typical Max Input Level: +5dBm (before damage) Return Loss: Impedance: Range: Precision: Impedance: >12dB 50 Ω 0 to 5VDC 0.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter TOD General Performances PIN 1 2 3 4 5 6 7 8 9 Shield Function: Standards: Name: Connector: Type: Control Baud rate: TOD Baud rate: Other: x1 Control / monitoring 1x RS-232 Serial Port 1 Female SubD9 RS-232/RS-485 9600 bps to 115200 bps 9600 bps No parity, 8 bits data, 1 bit stop Name RS232 Tx Rfu TOD Rx RS232 Rx GND RS485 Rx+ RS485 RxRS485 Tx+ RS485 TxGND Dir Out In In In In Out Out Figure 37: TOD/RS232 Port The information contai
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Alarm General PIN 1 2 3 4 5 6 7 8 9 Shield PIN 1 2 3 4 5 6 7 8 9 Shield Function: Name: Connector: Type: x2 Alarm relays GPIO / GPIO2 SubD9 connectors Dry contacts / GPI / VDCin / VDCout Name Dir Name Dir RELAY1_Normally_Open (Open when active alarm) 12 VDC output through 2.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.3 Front Panel signalization (LEDs description) A set of 4 LED’s indicate the exciter status: o A Power LED indicator o An Input LED indicator o An Output LED indicator o An Alarm LED indicator Behavior may differ depending on the exciter function and configuration.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.4 Power requirements The exciter must be powered by a 110-240VAC 50-60Hz voltage. The overall EXACT-V2 modulator consumes up to 70 W. The overall EXACT-V2 exciter consumes up to 120 W with optional +20 dB preamp. Figure 39: Power supply plug A yellow/green ground cable (0.75mm² min) must be connected to the small connector located between the power supply plug and the GPS antenna input.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Data Link Auto nego IP Characteristics Maximum Bit Rate: 100 Mbps Number of Processed IP Streams: 1 per physical interface Maxi Network Jitter Tolerance: 50 ms Ethernet MTU Length: Max 1500 bytes In ATSC 1.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter TOD Standard: Electrical Level: Baud Rate: Others: RS232 Limited to RX signal ±12v compatible 9600 bauds No parity, 8 bits data, 1 bit stop Connector: 3.5.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.5.5 Digital modulation Characteristics Typical Value Comment ATSC Modulation ATSC Mode: 8VSB Channel Bandwidth: 6 MHz Characteristics According to ATSC A/53 Typical Value Comment Modulation Performances In Band SNR (Eq. OFF): ≥ 30 dB EVM (Eq. OFF): ≤ 2.0% MER (Eq. OFF): ≥ 30 dB MER (Eq.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.5.6 Clock synchronization Characteristics Typical Value Comment External References External 10 MHz Reference Input Impedance: Level: Frequency: External 1 PPS Reference Input Level: Min Pulse Width: 10 MHz Reference Output: 50 Ohms -15 to +15 dBm 10 MHz ± 0.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Characteristics Typical Value Comment Clocks & Synchronization 10 MHz Lock Control Type: Digital Internal 10 MHz clock T°fStabilityf(Full Temperature Range): Tuning: With OCXO <± < ± 0.6 ppm Short Term Stability: < ± 1.10-11 Aging: Synchronization Cases External_10MHz_Locked: Over 1 s, 10 s 5.10-10 <± / day < ± 7.5.10-8 / year < ± 5.10-7 / 15 years Stability Aging <± 3.10-10 - External_10MHz_Unlocked: <± 3.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.5.7 RF and monitoring outputs Characteristics Typical Value Comment RF Output Adjustable Frequency Range: Step Size: Accuracy: Impedance: Output Level: Main Signal: 470 to 862 MHz 170 to 240 MHz 54 to 88 MHz 1 Hz 0.2 Hz 50 ohms 0 dBm ± 1 dB +20 dBm ± 1 dB EXACT-V2 EXACT-V2-20dB Stability: Return Loss: ± 0.1 dB / 10 °C > 13 dB > 12 dB EXACT-V2 EXACT-V2-20dB EXACT-V2-20dB Attenuation Range: Attenuation Step: 0 to 17 dB 0.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.5.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.5.9 Power level measurement inputs and AGC Characteristics Typical Value Comment Measurement Inputs (Forward and Reflected Power) AC Impedance: 50 ohms DC Impedance: ~ 80 kohms Return Loss: > 12 dB Nominal Input Level: -10 to 0 dBm 0 to 5 Vdc +5 dBm / 6Vdc In RF power mode In DC voltage mode Accuracy: 0.5 dB typical 0.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3.6 Conformity with EC Directive The CE marking is present on the RTM-50 product.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 4 3/10/2017 EXACT-V2 Installation MPD-1611291-A Page 63/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 64/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 4.1 Unpack the Unit Please check the shipping container for any damage due to transportation when receiving the product. If there is any damage please contact the carrier immediately. Carefully unpack the exciter from the storage box. Check the exciter for any damage due to transportation. Save the box and foam packaging in case the system needs to be shipped to another location or returned for repair. 4.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 4.2.1 Temperature alarms The maximum temperature levels are as follows: o o A warning will be raised when the internal temperature reaches higher than 68°C An alarm with output muting will trigger after internal temperatures reach higher than 71°C In both cases, the normal status conditions return when the temperature falls below 67°C. 4.2.2 Cooling methods Specific care must be taken concerning the cooling system.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 4.4 Initial Configuration Except otherwise specified at the time of order, the exciter is delivered with the basic configuration as described hereafter. The following configuration can also be retrieved with the “Set Default” command (not available in the WEB GUI) that will only keep IP settings and precorrection curves.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter ATSC 1.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Mute Conditions: GPI=0: Disabled GPI=1: Disabled Mute: Disable RFP Warning AGC Protection: Disabled RFP Error Protection Cycle: Disabled RFP Error Protection – No.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Max FWP Error: 120 % (not changed by default command) RF input RFP Input Type: (not changed by default command) RFP Coupler Attenuation: 0 dB (not changed by default command) Max RFP Warning: 10 % (not changed by default command) 20 % Max RFP Error: (not changed by default command) Dual-Drive Redundancy: Disabled GPO2 Opening Triggers: None GPO3 Opening Triggers: Output error Alarm error RF Switch Monitoring: Disabled
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5 3/10/2017 Operation MPD-1611291-A Page 71/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 72/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5.1 Operation Generalities 5.1.1 Local Operation The product can be locally controlled using the front panel menu. It is composed of an LCD screen and 6 buttons to navigate the control/monitoring menu. The primary features are available using the front panel but for complete access to the unit, please use the web GUI. 5.1.2 Remote Operation The product can be controlled using any web browser.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5.2 Embedded Web GUI Description 5.2.1 Requirements To connect to the EXACT-V2 web interface, a web browser with Flash Player is mandatory. 5.2.2 Connection to EXACT-V2 Using the web browser, the user will access the modulator by typing “http://[IP]”, where [IP] is the IP address of the equipment.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5.2.3 General Overview 1 2 3 Area 1 is the header of the main window. It presents the login/logout functions as well as equipment identification. Area 2 is the main window. It presents either the parameters settings or the detailled monitoring. Area 3 is the “Status Overview” area. It presents an overview of the main status.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5.2.4 Settings Tab The Settings tab can be accessed by clicking on the « Settings » header. The left part of the screen describes the settings menu while the right part presents each screen related to one menu item. When any parameter is changed, it is highlighted.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter A message in the main window header allows the user to verify if the settings have been modified and not applied. The Apply button appears to confirm the application. If any change must be discarded, the « Refresh » button can be used to display the current configuration in the settings screens.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5.2.5 Monitoring Tab The Monitoring tab can be accessed clicking on the Monitoring header. It is divided into 2 independent screens to allow the user to monitor two different blocks. To select a block to monitor, a Drag and Drop feature can be used from the “Status Overview” area to one of the two areas.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 5.2.6 Log File EXACT-V2 features an onboard Log file to consult the different information, warning or error that occurred on the product. To access to the Log File window, please press the envelop. Then the log file window is displayed. Notes: For more information concerning this topic, please refer to the dedicated Application Note. 5.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 80/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 6 3/10/2017 Maintenance & Troubleshooting MPD-1611291-A Page 81/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 82/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 6.1 Versions management The product is defined by its commercial reference and its version numbers. Product versions are managed using two separate and independent three digits numbers: • The hardware version • The software version The version of the product is defined for example as: ............... H100-S112 This means that the hardware of the product is in version 1.00 and the software is in version 1.10.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 6.3 Licence key management New licences for either TSOIP or SNMP may be purchased separately and added to the exciter.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter (5) Alarm due to primary clock reference loss is defined in a specific table. 6.4.
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 86/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Appendix A 3/10/2017 GPS Installation Recommendations MPD-1611291-A Page 87/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 88/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter While doing GPS installation and setup for a product with an embedded GPS receiver, it is highly recommended to respect the following conditions: Considering: Pgps as the power of the incoming signal (nominal value over the covered area) Ga as the gain of the dedicated GPS antenna Gc as the losses of the several RF components (cable, connectors,…) Gt as the total Gain of the RF chain Gt = Ga + Gc The user shall respect the following cond
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 90/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter Appendix B 3/10/2017 Example of GPS Antenna MPD-1611291-A Page 91/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 92/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 93/94
USER MANUAL MPD-1611291-A EXACT-V2 High End Rack Modulator / Exciter 3/10/2017 MPD-1611291-A Page 94/94