Section 7 Energy Distribution and Control
7. General Description
The energy distribution circuits on the transmitter can be configured on the following possibilities:
208V
AC
-220 V
AC
240 V
AC
mono-phase.
208V
AC
-220 V
AC
240 V
AC
bi-phase.
208V
AC
-220 V
AC
240 V
AC
three-phase.
360V
AC
three-phase.
Fig.7.1: Energy Distribution Bipolar Main Breaker on left, manual starter on the center and module 4147 battery
charger.
In all versions above, the NEUTRAL wire is present, however not always connected and so no need
to integrate it within the grounding system of the station. It is however MANDATORY to connect the neutral cable on
the 208Vac mono-phase, and 360Vac three-phase.
WARNING: Do not operate without the GROUND connection. The absence of
grounding is risky for personnel SAFE, equipment reliability besides jeopardize
the quality of the DTV transmission.