AT7400 Owner Manual Rev. 2.0 October 2006-10-23 ANNEX A Section 7 - 5/9
Parts list for the module 4443 is as follows:
Secondary breaker.
Timer, 2.5 seconds.
Mechanical delay 2 seconds.
Two 18Ω/50W resistors in parallel.
On ON/OFF switch with 2 independent contacts.
No matter which version is choose, 208/220/240 Vac will always be voltage to be delivered for the exciter
drawer, and power amplifier drawers.
Fig. 7.6: On the right the drawer AC power connector, on the right AC mains reading on the center pins of the same
connector.
7.2.3. Energy Distribution and Control - Operational Short Description
When ON the 30A breaker connects the 2 main phases to the main bi-phase breaker terminal. The main
breaker will be switching ON, module 4443, only if:
(a) The phase detector, PCB CIM6241A sends the command signal confirming the presence of the all phases.
3 in sequence relay close-open-close noise is audible.
(b) The interlock is closed,
(c) The manual switch ON/OFF is pressed.