Installation User guide

Hired-Hand Manufacturing, Inc. 1733 County Road 68 Bremen, Alabama 35033 PH 256-287-1000 FAX 256-287-2000
Manual Part No. 4801-5371 Rev 6-07 Page 1 of 2
Parts List
Tools Required
Part Number Description Quantity Drill
6409-2200 /Vent Door GVD CAB ASSY 1 Saws
6409-2202 /Vent Door GVD WEIGHT ASSY 1
1004-0050 SCRW SM #14x1 HX W SL Tek Z 8
1004-7120 SCRW Lag 1/4x1-1/4 Zinc 8
Directions
1. Mark rough opening for vent door on wall. The
vent should be a minimum of 8.5" (21.6 cm)
from the ceiling. See Figure 2.
2. Cut rough opening to size as shown in Table A
above.
3. Install vent. Insure that vent is mounted squarely in opening
and oriented for the proper air flow direction. Screws are
provided for either mounting in wood framing (1004-7120) or
metal (1004-0050).
4. Install Weight Assembly.
5. Adjust Weight to desired setting.
6. See the Vent Performance Chart on page 2.
Part Number Vent Size Rough Opening
6609-2200 12.75” x 45.625 (32.38 cm x 115.89 cm) 13.5” x 46.5” (34.29 cm x 118.11 cm)
GRAVITY
VENT DOOR
Installation
Table A
Air Flow
8.5" minimum
from
ceiling
Fi
g
ure 2
Vent Mountin
g
Fi
g
ure 3
Gravit
y
Vent Door Front & Side View
Weight
Assembly
Cabinet
Assembly
Figure 1
Gravity Vent Door