ORIGINAL OPERATING INSTRUCTIONS PS 1000 x‑scan It is essential that the operating instructions are read before the tool is operated for the first time. Always keep these operating instructions together with the tool. Ensure that the operating instructions are with the tool when it is given to other persons. Contents 1. General information 2. Description 3. Before use 4. Operation 5. Settings Page 1 2 2 2 5 1 These numbers refer to the corresponding illustrations.
concerned should take place to obtain agreement, prior to any measurements being performed. en 3. Before use 3.1 Inserting the battery pack and switching on the device 3 1. Fully charge the PSA 81 battery pack (see Operating instructions for PUA 81 power supply). 2. When charged, insert the battery pack. 3. Switch the tool on by pressing the on/off button. Outside the operating temperature, the fault message no. 00012 is displayed and the device is automatically switched off.
4.3 Carrying out Quickscan detection Locating objects embedded in concrete structures in real time mode for direct marking. en 1. 2. 3. 4. 5. 6. 7. Switch the device on and navigate to the home screen using the Home button. Select the "Quickscan detection" function. Hold the scanner onto the surface to be examined. Start the measurement with the start/stop button. A beep is heard which signals the start of the measurement and a red recording point appears in the display field.
5. en 6. 7. Move the scanner in the direction which you preset. If the scanning movement is very fast, an audible and visible warning is issued. If the scanning movement is too fast, the measurement is canceled. Do not change the scanning direction. If you move the scanner more than 16 cm (7") in the other direction, the measurement will be automatically canceled. End the measurement with the start/stop button. A double beep signals that the measurement has ended.
2. 3. Select the desired project. The active project is marked by a "dog-eared" crease. Select the desired scan. The scan is displayed and can be reanalyzed. en 5. Settings 5.1 You can adjust the following: Brightness Volume level Date / time Energy modes Country settings (country, region, language, unit) NOTE Press the "Help" function button to call up the complete Operating instructions.
13 FCC-Hinweis (gültig in USA) / ICES-Hinweis (gültig in Kanada) FCC statement (valid in USA) CAUTION This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Operation of this device is restricted to law enforcement, fire and rescue officials, scientific research institutes, commercial mining companies, construction companies and private parties operating on behalf of these groups. Operation by any other party is a violation of 47 U.S.C. § 301 and could subject the operator to serious legal penalties. Coordination Requirements (a) UWB imaging systems require coordination through the FCC before the equipment may be used.
Note: This form is only for Domestic United States users. Failure to do this is a violation of Federal law. 1. Date: 2. Company name: 3. Address: 4. Contact Information [contact name and phone number]: 5. Area Of Operation [state(s)]: 6. Equipment Identification See below Brand Name: PS 1000 FCC-ID: SDL-PS1000R1 7. Receipt Date Of Equipment: Fax this form to the FCC at: 202-418-1944 or mail to: Frequency Coordination Branch, OET Federal Communications Commission 445 12th Street, SW Washington, D.C.
For Canadian customers: This device shall be operated only where directed to the ground or wall, and is in contact with the ground or wall surface. This device shall be operated only by law enforcement agencies, scientific research institutes, commercial mining companies, construction companies, and emergency rescue or fire-fighting organizations.