Hillstone A200 Series Hardware Reference Guide
Copyright 2021Hillstone Networks. All rights reserved. Information in this document is subject to change without notice. The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of those agreements.
Contents Contents ...................................................................................................................................... 3 Preface ......................................................................................................................................... 6 About This Manual ................................................................................................................ 6 Document Conventions .......................................................
Verifying the Parts Received .............................................................................................. 15 Installation Devices/Tools/Cables ................................................................................... 16 Chapter 3 Installation .............................................................................................................. 16 Installing the Device on a Workbench .............................................................................
EU Conformity Statement ..................................................................................................
Preface About This Manual Thanks for choosing the network security products from Hillstone Networks. This document is an installation manual for the Hillstone A200Series device to help you install the device properly.
Hardware Overview The size of A200 series equipment of Shanshi Netcom is 180 * 110 * 28mm, which belongs to desktop equipment and is used on the workbench. Front Panel The front panel of A200 consists of several LED indicators (1 Power LED, 1 Status LED). Figure: A200 Front Panel Power LED Status LED The front panel of A200W consists of several LED indicators (1 Power LED, 1 Status LED, 1 WLAN LED).
Table: Front Panel LED Descriptions LED Color/Status Description PWR Green/Always on The device power is running normally. Off The device is powered off. Green/Blinking The system is running normally. Off The system has not been booted/is booting/has failed to boot. Green/Always on The device has detected a built-in WLAN module present. Green/Blinking WLAN is in data receiving and sending state Green/Always on The link between this port and its peer device is in normal status.
Table: System Parameters Item Description Fixed Ports 5 Gigabit port A200 Series 1 USB 3.0 ports 1 CON port 1 SFP Smooth Mouth CPU 88f3720 Binuclear DDR4 SDRAM 2GB Flash Memory 4GB Dimensions (W×D×H) W180.0mm * D110.0mm *H28.0mm Weight Net weight: 0.64kg Gross weight:1.
Attribute Description Port Standard RS-232C Baud Rate 115200 bit/s Services Connect the CON port to the serial port of a PC and run a terminal emulation program on the PC to configure the device Transmission Medium Console cable USB Port The A200-Series device provides up to 1 USB 2.0 host ports. Attributes for the USB host ports are shown in the table below: Table: USB 2.0 Host Port Attributes Attribute Description Connector USB Type-A interface Port Standard USB 2.
Table: SFP Port Attributes Attribute Description Connector SFP Frame Format Ethernet_II Ethernet_SNAP Negotiation Mode SFP optical module SFP copper module 1000Mbps 10/100/1000Mbps autosensing (some only supports 1000Mbps) Full/half-duplex The SFP port supports the following two types of modules: SFP optical module SFP copper module If an SFP optical module is applied to an SFP port, you should use a cable with a LC-type optical connector.
Attribute Description Short-haul Multimode Optical Module (850nm) Mediumhaul Singlemode Optical Module (1310nm) Long-haul single-mode optical module (1310nm) Central 850nm Waveleng th 1310nm 1310nm Optional Original Hillstone Optical Module TRANLX10 TRANLX40 TRANSX 1550nm Medium-haul Single-mode Optical Module (1310nm) Long-haul Single-mode Optical Module (1310nm) Long-haul Single-mode Optical Module (1550nm) Ultra-longhaul Singlemode Optical Module (1550nm) 1550nm 1310nm 1550nm 1550nm T
CLR Button The CLR button is the pinhole of the front panel and is used to reset the device back to the factory default settings. You can restore access to the device with this button if the login password is lost. Notes: Use this button with caution. Resetting the device will clear all existing configurations. To restore the factory default settings, take the following steps: 1. When the device is working, use a pin to press the CLR button in the pinhole and the device will restart. 2.
Chapter 2 Installation Preparations Introduction This chapter introduces the preparations before installing the Hillstone A200-Series device, including the installation site environment requirements. This chapter includes the following sections: Installation site environment requirements Installation Site Environment Requirements The A200-Series device is designed for indoor use. To ensure the normal operation and to prolong the service lifetime, the installation site must meet the requirements below.
Take dustproof measures for the equipment room. Maintain proper humidity and temperature levels. Do not disassemble the device without permission from the vendor, or you may cause danger and void your warranty. EMI Prevention All possible Electromagnetic Interference (EMI) sources, external or internal, affect the device in the way of capacitance coupling, inductance coupling, electromagnetic radiation, and common impedance (including the grounding system) coupling.
Installation Devices/Tools/Cables The SG-6000A-Series device is shipped with a power cable and a console cable, and you should have the following items before the installation: Terminal: Configuration terminal (e.g. an ordinary PC). Tools: Cross screwdriver and ESD wrist strap/antistatic gloves. Cables: Power cable, console cable and Ethernet cable. Chapter 3 Installation A yellow seal with dark ink characters is stuck on a mounting screw of the chassis. Keep the seal intact.
Check the following specifications when installing the device on a workbench: Make sure the workbench is stable and well grounded. Make sure the intake and the exhaust vents are unblocked, and keep the device well ventilated. Do not place any heavy object on the top of the chassis. Connecting Cables The cable connection of A200 series equipment includes configuration cable connection, Ethernet cable connection and power cable connection..
2. Connect the console cable. Connect the RJ-45 end of the console cable to the device's Console port (labeled CON), and then connect the DB-9 end to the console terminal. Connecting the Ethernet Cable The A200-Series device provides gigabit Ethernet ports, SFP ports. The gigabit Ethernet port can be connected by a straight-through cable (also called standard cable) or crossover cable.
Connecting a Power Adapter For some models, you need to connect the device to the external AC power supply by using the power adapter to power the device: To connect a power adapter, take the following steps: 1. Insert the DC output plug of the power adapter into the DC power interface on the back panel of the device. 2. Connect the power adapter to the external AC power supply.
Chapter 4 Boot and Configuration Introduction This chapter describes how to perform initial system boot and basic configuration of the Hillstone A200-Series device, using a PC as the console terminal. Establishing a Configuration Environment The A200-Series device supports both local and remote configuration. Administrators can use the following configuration methods.
parameters of the terminal session to 115200bps, 8 data bits, 1 stop bit, none parity, and none flow control, as shown in the figure below: 3. Switch on the power supply, and the device performs self-test and initializes the configuration automatically. If the booting succeeds, the system will display the command line prompt "login". Enter the default administrator name and password "hillstone" at the "login" and "password" prompts, press Enter.
2. Launch a Web browser of the management PC, enter the URL https://192.168.1.1 in the address bar, and then press Enter. 3. Type the default administrator name (hillstone) and password (hillstone) into the text boxes respectively. 4. 5. Select the language you want to use. Click Login to enter the home page. After login, please change the default password of the device in time. Then you can set other configurations to the device.
Chapter 5 Hardware Maintenance and Replacement Introduction This chapter explains startup and shutdown methods of the Hillstone A200-Series device. Startup After being connected to the power supply by the power cord for the first time, the device will automatically start up. If the device is shut down by pressing the power button or using the shutdown command, and the power cord has not been disconnected after shutdown, you can press the power button to power on the device.
According to the status of the power indicator, the user can judge whether the power system of the product fails. For the status and meaning of the power indicator, please refer to the meaning of the indicator. When the power supply system works normally, the power indicator should keep green and always on; when the power indicator is not on, please check the equipment as follows: Whether the power line of the equipment is connected correctly.
Chapter 7 Addendum Statement Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Avis d'Industrie Canada Cet appareil est conforme à la norme CNR-210 des règlements d’Industrie Canada. Son fonctionnement est sujet aux deux conditions suivantes: 1) Cet appareil ne doit pas provoquer d’interférences et 2) Cet appareil doit accepter toutes les interférences, y compris celles pouvant entraîner son dysfonctionnement.