DS-K1T981 Series Access Control Terminal User Manual
DS-K1T981 Series Access Control Terminal User Manual Legal Information ©2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons.
DS-K1T981 Series Access Control Terminal User Manual DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed.
DS-K1T981 Series Access Control Terminal User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Danger Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. Caution Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
DS-K1T981 Series Access Control Terminal User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
DS-K1T981 Series Access Control Terminal User Manual under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.
DS-K1T981 Series Access Control Terminal User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. Dangers: Follow these safeguards to prevent serious injury or death.
DS-K1T981 Series Access Control Terminal User Manual Cautions: ● ● ● ● ● ● ● ● ● ● ● ● ● Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
DS-K1T981 Series Access Control Terminal User Manual Available Models Product Name Access Control Terminal Model DS-K1T981M DS-K1T981MF Use only power supplies listed in the user instructions: Model Manufacturer Standard C2000IC12.0-24P-DE MOSO Power Supply Technology Co., Ltd. CEE C2000IC12.0-24P-GB MOSO Power Supply Technology Co., Ltd. BS KPL-040F-VI Channel Well Technology Co Ltd.
DS-K1T981 Series Access Control Terminal User Manual Contents Chapter 1 Overview .................................................................................................................... 1 1.1 Overview ................................................................................................................................ 1 1.2 Features ................................................................................................................................. 1 1.2.
DS-K1T981 Series Access Control Terminal User Manual 6.1 Set Application Mode .......................................................................................................... 30 6.2 Set Network Parameters ...................................................................................................... 31 6.3 Access to Platform ............................................................................................................... 32 6.4 Privacy Settings ................................
DS-K1T981 Series Access Control Terminal User Manual 7.4.3 Export Data ................................................................................................................. 55 7.5 Identity Authentication ........................................................................................................ 56 7.5.1 Authenticate via Single Credential .............................................................................. 56 7.5.2 Authenticate via Multiple Credential ......................
DS-K1T981 Series Access Control Terminal User Manual 8.5.4 Set DST ........................................................................................................................ 76 8.5.5 View Open Source Software License ........................................................................... 77 8.5.6 Upgrade and Maintenance ......................................................................................... 77 8.5.7 Log Query ...............................................................
DS-K1T981 Series Access Control Terminal User Manual 9.3.2 Import Resources to Group ....................................................................................... 115 9.4 Person Management .......................................................................................................... 116 9.4.1 Add Organization ...................................................................................................... 116 9.4.2 Import and Export Person Identify Information ....................
DS-K1T981 Series Access Control Terminal User Manual Chapter 1 Overview 1.1 Overview Access control terminal is a kind of access control device for iris recognition and face recognition, which is mainly applied in security access control systems, such as logistic centers, airports, university campuses, alarm centrals, dwellings, etc. 1.2 Features 1.2.
DS-K1T981 Series Access Control Terminal User Manual ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Support mask wearing detection Supports tamper alarm, door opening alarm by external force, duress card and duress password alarm Support multiple display modes, including normal mode, advertisement mode, and simple mode.
DS-K1T981 Series Access Control Terminal User Manual Chapter 2 Appearance Refer to the following contents for detailed information of the access control terminal: Figure 2-1 Access Control Terminal Diagram Table 2-1 Description of Access Control Terminal No.
DS-K1T981 Series Access Control Terminal User Manual No.
DS-K1T981 Series Access Control Terminal User Manual Chapter 3 Installation 3.1 Installation Environment ● ● Install the device at least 2 meters away from the light, and at least 3 meters away from the window or the door. Make sure the environment illumination is more than 100 Lux. Note For details about installation environment, see Tips for Installation Environment. 3.2 Flush Mounting with Gang Box Before You Start Remove the back sheet of the device. Steps 1.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-1 Install Gang Box 3. Secure the mounting plate on the bracket with 2 supplied screws (SC-K1M4X6-SUS). Figure 3-2 Install Mounting Plate 4. Route the cable through the cable hole, wire the cables and insert the cables in the gang box.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-3 Apply Silicone Sealant Note Apply Silicone sealant among the cable wiring area to keep the raindrop from entering. 5. Align the device with the mounting plate, and secure the device on the mounting plate with 1 supplied screw (SC-KM3X6-T10-SUS).
DS-K1T981 Series Access Control Terminal User Manual Figure 3-4 Secure Device 6. After installation, for the proper use of the device (outdoor use), stick the protection film (parts of models supplied) on the screen. 3.3 Surface Mounting Steps Note The additional force shall be equal to three times the weight of the equipment. The equipment ad its associated mounting means shall remain secure during the installation.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-5 Mounting Template 2. Drill 2 holes on the wall or other surface according to the Hole 1 on the mounting template. 3. Insert the plastic sleeve of the provided expansion screw into the punched hole. 4. Install the mounting plate on the wall with the 2 supplied screws (SC-KA4×22-SUS).
DS-K1T981 Series Access Control Terminal User Manual Figure 3-6 Install Bracket 5. Align the holes to the mounting plate and secure the mounting plate on the bracket with the 2 supplied screws (SC-K1M4×6-SUS). Figure 3-7 Install Mounting Plate 6. Route the cable through the cable hole, wire the cables and insert the cables.
DS-K1T981 Series Access Control Terminal User Manual Note If the device is installed outdoor, you should apply silicone sealant to the wiring exit to avoid water from entering. Figure 3-8 Apply Silicone Sealant 7. Align the device with the mounting plate and hang the device on the mounting plate. 8. Use 1 supplied screw (SC-KM3×6-T10-SUS) to secure the device and the mounting plate.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-9 Secure Device 9. After installation, for the proper use of the device (outdoor use), stick the protection film (parts of models supplied) on the screen. 3.4 Mount With Bracket 3.4.1 Preparation before Mounting with Bracket Steps 1. Drill holes on the turnstile's surface according to the figure displayed below. And install waterproof nut. Note Solder after pressing rivets to avoid water from entering.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-10 Drill Holes on Turnstile 2. If the installation angle needs to be 180° perpendicular to the body of the turnstile, the following operations are required. 1) Take off the 3 screws shown in the following figure. Figure 3-11 Take off Screws 2) Rotate the fixed part by 180°, and install the 3 screws back. Figure 3-12 Rotate Fixed Part 3.4.2 Bracket Mounting Steps 1.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-13 Install Mounting Template 2. Remove the back cover plate, route the cables through the cable hole, and connect them to the corresponding external devices' cables. 3. Install the back cover plate back, and install the device on the bracket with 1 supplied screw (SCKM3×6-T10-SUS). Figure 3-14 Install Device 4. After installation, for the proper use of the device (outdoor use), stick the protection film (parts of models supplied) on the screen.
DS-K1T981 Series Access Control Terminal User Manual 3.4.3 Mount With Cylinder Bracket Preparation before Mounting with Bracket Make sure you have drilled holes on the turnstile. If not, follow the steps below to drill holes. Steps 1. Use 4 screws (M3 or M4), secured by flange nuts, to install the reinforcing board on the inner surface of the turnstile. Note The distance between the turnstile and the edge should be no longer than 10 mm. 2.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-16 Solder Tubes Cylinder Bracket Mounting Steps 1. Install the base on the turnstile. 1) Align the hole on the turnstile and place the base on the turnstile. 2) Rotate the base to the acquired place and make sure the device will face a correct direction. 3) Secure the base with 4 SC-OM6×12-H-SUS screws. Figure 3-17 Install Base 2. Fix the mounting plate into the bracket by 4 SC-K1M4×8-SUS screws.
DS-K1T981 Series Access Control Terminal User Manual Figure 3-18 Fix Mounting Plate 3. Route the cables through the cable hole on the turnstile. 4. Fix the face recognition terminal into the mounting plate with 1 SC-KM3×6-T10-SUS screw. Figure 3-19 Fix Mounting Plate 5. After installation, for the proper use of the device (outdoor use), stick the protection film (parts of models supplied) on the screen.
DS-K1T981 Series Access Control Terminal User Manual Chapter 4 Wiring The device supports connecting to the RS-485 terminal, the door lock, the exit button, the alarm output/input devices, the Wiegand card reader, the access controller, and the power supply. You can wire the peripherals according to the descriptions below.
DS-K1T981 Series Access Control Terminal User Manual Figure 4-1 Terminal Diagram The descriptions of the terminals are as follows: Table 4-1 Terminal Descriptions Group Group A No.
DS-K1T981 Series Access Control Terminal User Manual Group No.
DS-K1T981 Series Access Control Terminal User Manual ● ● ● Note If connects to an access controller, you should set the Wiegand direction as Output to transmit authentication information to the access controller. For details about Wiegand direction settings, see Set Wiegand Parameters . Do not wire the device to the electric supply directly. 4.3 Wire Secure Door Control Unit You can connect the terminal with the secure door control unit. The wiring diagram is as follows.
DS-K1T981 Series Access Control Terminal User Manual Type 1 Note The fire system controls the power supply of the access control system. Figure 4-4 Wire Device Figure 4-5 Wire Secure Door Control Unit Type 2 Note The fire system (NO and COM, normally open when powering off) is connected with the lock and the power supply in series. When an fire alarm is triggered, the door remains open. In normal times, NO and COM are closed.
DS-K1T981 Series Access Control Terminal User Manual Figure 4-6 Wiring Device Figure 4-7 Wiring Secure Door Control Unit 4.4.2 Wiring Diagram of Door Locked When Powering Off Lock Type: Cathode Lock, Electric Lock, and Electric Bolt (NC) Security Type: Door Locked When Powering Off Scenario: Installed in Entrance/Exit with Fire Linkage ● ● Note The Uninterpretable Power Supply (UPS) is required.
DS-K1T981 Series Access Control Terminal User Manual Figure 4-8 Device Wiring Figure 4-9 Wiring Diagram 24
DS-K1T981 Series Access Control Terminal User Manual Chapter 5 Activation You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page. Activation via the device, SADP tool and the client software are supported. The default values of the device are as follows: ● The default IP address: 192.0.0.64 ● The default port No.: 8000 ● The default user name: admin 5.
DS-K1T981 Series Access Control Terminal User Manual Figure 5-1 Activation Page Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
DS-K1T981 Series Access Control Terminal User Manual ● ● ● After activation, you can add the device to the platform. For details, see Access to Platform . After activation, if you need to set privacy, you should check the item. For details, see Privacy Settings . After activation, if you need to add administrator to manage the device parameters, you should set administrator. For details, see Add Administrator . 5.2 Activate via Web Browser You can activate the device via the web browser. Steps 1.
DS-K1T981 Series Access Control Terminal User Manual Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. 4.
DS-K1T981 Series Access Control Terminal User Manual 5. Click Activate to open the Activation dialog. 6. Create a password in the password field, and confirm the password. Caution The password strength of the device can be automatically checked.
DS-K1T981 Series Access Control Terminal User Manual Chapter 6 Quick Operation 6.1 Set Application Mode After activating the device, you should select an application mode for better device application. Steps 1. On the Welcome page, select Indoor or Others from the drop-down list. Figure 6-1 Welcome Page 2. Tap OK to save. ● ● Note You can also change the settings in System Settings. If you install the device indoors near the window or the face recognition function is not working well, select Others.
DS-K1T981 Series Access Control Terminal User Manual ● ● If you do not configure the application mode and tap Next, the system will select Indoor by default. If you activate the device via other tools remotely, the system will select Indoor as the application mode by default. 6.2 Set Network Parameters After activation and select application mode, you can set the network for the device Steps 1. When you enter the Select Network page, tap Wired Network or Wi-Fi for your actual needs.
DS-K1T981 Series Access Control Terminal User Manual Wired Network Note Make sure the device has connected to a network. If enable DHCP, the system will assign the IP address and other parameters automatically. If disable DHCP, you should set the IP address, the subnet mask, and the gateway. Wi-Fi Select a Wi-Fi and enter the Wi-Fi's password to get connected. Or tap Add Wi-Fi and enter the Wi-Fi's name and the password to get connected. 3. Optional: Tap Skip to skip network settings. 6.
DS-K1T981 Series Access Control Terminal User Manual Figure 6-3 Access to Hik-Connect 2. Tap Next. Note If you tap Previous to return to the Wi-Fi configuration page, you need to tap the connected WiFi or connect another Wi-Fi to enter the platform page again. 6.4 Privacy Settings After activation, selecting application mode, and selecting network, you should set the privacy parameters, including the picture uploading and storage. Select parameters according to your actual needs.
DS-K1T981 Series Access Control Terminal User Manual Figure 6-4 Privacy Upload Captured Pic. When Auth. (Upload Captured Picture When Authenticating) Upload the pictures captured when authenticating to the platform automatically. Save Captured Pic. When Auth. (Save Captured Picture When Authenticating) If you enable this function, you can save the picture when Authenticating to the device. Save Registered Pic.
DS-K1T981 Series Access Control Terminal User Manual Tap Next to complete the settings. 6.5 Set Administrator After device activation, you can add an administrator to manage the device parameters. Before You Start Activate the device and select an application mode. Steps 1. Optional: Tap Skip to skip adding administrator if required. 2. Enter the administrator's name (optional) and tap Next. Figure 6-5 Add Administrator Page 3. Select a credential to add. Note Up to one credential should be added.
DS-K1T981 Series Access Control Terminal User Manual : Face forward at the camera. Make sure the face is in the face recognition area. Click to capture and click to confirm. : Press your finger according to the instructions on the device screen. Click to confirm. : Enter the card No. or present card on the card presenting area. Click OK. 4. Click OK. You will enter the authentication page. Status Icon Description / Device is armed/not armed. / Hik-Connect is enabled/disabled.
DS-K1T981 Series Access Control Terminal User Manual Chapter 7 Basic Operation 7.1 Login Login the device to set the device basic parameters. 7.1.1 Login by Administrator If you have added an administrator for the device, only the administrator can login the device for device operation. Steps 1. Long tap on the initial page for 3 s and slide to the left/right by following the gesture to enter the admin login page. Figure 7-1 Admin Login 2.
DS-K1T981 Series Access Control Terminal User Manual Figure 7-2 Home Page Note The device will be locked for 30 minutes after 5 failed fingerprint or card attempts. 3. Optional: Tap and you can enter the device activation password for login. 4. Optional: Tap and you can exit the admin login page. 7.1.2 Login by Activation Password You should login the system before other device operations. If you do not configure an administrator, you should follow the instructions below to login. Steps 1.
DS-K1T981 Series Access Control Terminal User Manual - If you haven't added an administrator for the device, enter the password. 3. Tap OK to enter the home page. Note The device will be locked for 30 minutes after 5 failed password attempts. Figure 7-3 Home Page 7.2 Communication Settings You can set the wired network, the Wi-Fi parameter, the RS-485 parameters, the Wiegand parameters, ISUP and access to Hik-Connect on the communication settings page.
DS-K1T981 Series Access Control Terminal User Manual 7.2.1 Set Wired Network Parameters You can set the device wired network parameters, including the IP address, the subnet mask, the gateway, and DNS parameters. Steps 1. Tap Comm. (Communication Settings) on the Home page to enter the Communication Settings page. 2. On the Communication Settings page, tap Wired Network. Figure 7-4 Wired Network Settings 3. Set IP Address, Subnet Mask, and Gateway.
DS-K1T981 Series Access Control Terminal User Manual Steps Note The function should be supported by the device. 1. Tap Comm. (Communication Settings) on the Home page to enter the Communication Settings page. 2. On the Communication Settings page, tap. Figure 7-5 Wi-Fi Settings 3. Enable the Wi-Fi function. 4. Configure the Wi-Fi parameters. - Select a Wi-Fi from the list, and enter the Wi-Fi's password. Tap OK. - If the target Wi-Fi is not in the list,tap Add Wi-Fi. Enter the Wi-Fi's name and password.
DS-K1T981 Series Access Control Terminal User Manual - If disable DHCP, you should enter the IP address, the subnet mask, and the gateway manually. 6. Tap OK to save the settings and go back to the Wi-Fi tab. to save the network parameters. 7. Tap 7.2.3 Set RS-485 Parameters The face recognition terminal can connect external access controller, secure door control unit or card reader via the RS-485 terminal. Steps 1. Tap Comm.
DS-K1T981 Series Access Control Terminal User Manual Note If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address according to the door No. 4. Tap the back icon at the upper left corner and you should reboot the device if you change the parameters. 7.2.4 Set Wiegand Parameters You can set the Wiegand transmission direction. Steps 1. Tap Comm.
DS-K1T981 Series Access Control Terminal User Manual Before You Start Make sure your device has connect to a network. Steps 1. Tap Comm. → ISUP . Figure 7-8 ISUP Settings 2. Enable the ISUP function and set the ISUP server parameters. ISUP Version Set the ISUP version according to your actual needs. Central Group Enable central group and the data will be uploaded to the center group. Main Channel Support N1 or None. ISUP Enable ISUP function and the data will be uploaded via EHome protocol.
DS-K1T981 Series Access Control Terminal User Manual Set the ISUP server's port No. Note Port No. Range: 0 to 65535. Device ID Set device serial no. Password If you choose V5.0, you should create an account and ISUP key. If you choose other version, you should create an ISUP account only. ● ● Note Remember the ISUP account and ISUP key. You should enter the account name or the key when the device should communicate with other platforms via ISUP protocol. ISUP key range: 8 to 32 characters. 7.2.
DS-K1T981 Series Access Control Terminal User Manual Steps 1. Long tap on the initial page for 3 s and slide to the left/right by following the gesture and enter the device backend. 2. Tap User → + to enter the Add User page. 3. Edit the employee ID. Note ● The employee ID should be less than 32 characters. And it can be a combination of lower letters, upper letters, and numbers. ● The employee ID should not be duplicated. 4. Tap the Name field and input the user name on the soft keyboard.
DS-K1T981 Series Access Control Terminal User Manual Note ● For details about adding a face picture, see Add Face Picture . ● For details about adding a fingerprint, see Add Fingerprint . ● For details about adding a card, see Add Card . ● For details about adding a iris, see Add Iris . ● For details about adding a password, see View PIN code . 6. Optional: Set the administrator's authentication type. Note For details about setting the authentication type, see Set Authentication Mode . 7.
DS-K1T981 Series Access Control Terminal User Manual Figure 7-9 Add Face Picture 6. Look at the camera. ● ● ● Note Make sure your face picture is in the face picture outline when adding the face picture. Make sure the captured face picture is in good quality and is accurate. For details about the instructions of adding face pictures, see Tips When Collecting/ Comparing Face Picture .
DS-K1T981 Series Access Control Terminal User Manual Normal User The User is the normal user. The user can only authenticate or take attendance on the initial page. 10. Tap to save the settings. 7.3.3 Add Fingerprint Add a fingerprint for the user and the user can authenticate via the added fingerprint. Steps ● ● Note The function should be supported by the device. Up to 100000 fingerprints can be added. 1.
DS-K1T981 Series Access Control Terminal User Manual Normal User The User is the normal user. The user can only authenticate or take attendance on the initial page. 8. Tap to save the settings. 7.3.4 Add Card Add a card for the user and the user can authenticate via the added card. Steps Note Up to 50000 cards can be added. 1. Long tap on the initial page for 3 s and slide to the left/right by following the gesture and log in the backend. 2. Tap User → + to enter the Add User page. 3.
DS-K1T981 Series Access Control Terminal User Manual The user is the administrator. Except for the normal attendance function, the user can also enter the Home page to operate after authenticating the permission. Normal User The User is the normal user. The user can only authenticate or take attendance on the initial page. 10. Tap to save the settings. 7.3.5 Add Iris Add user's iris information to the device. And the user can use the iris information to authenticate.
DS-K1T981 Series Access Control Terminal User Manual Figure 7-10 Add Iris 6. Look at the camera. Note ● Make sure your eyes in frame when adding the iris. ● Make sure the captured iris is in good quality and is accurate. ● Remove your glasses when adding the iris. ● Keep your position when adding the iris. 7. Tap to save the iris information. 8. Optional: Tap and adjust your eyes position to add the iris again. 9. Set the user role. Administrator The user is the administrator.
DS-K1T981 Series Access Control Terminal User Manual The User is the normal user. The user can only authenticate or take attendance on the initial page. 10. Tap to save the settings. 7.3.6 View PIN code Add a PIN code for the user and the user can authenticate via the PIN code. Steps 1. Long tap on the initial page for 3 s and slide to the left/right by following the gesture and log in the backend. 2. Tap User → + to enter the Add User page. 3. Tap the Employee ID. field and edit the employee ID.
DS-K1T981 Series Access Control Terminal User Manual 7.3.7 Set Authentication Mode After adding the user's face picture, password, or other credentials, you should set the authentication mode and the user can authenticate his/her identity via the configured authentication mode. Steps 1. Long tap on the initial page for 3 s and slide to the left/right by following the gesture and log in the backend. 2. Tap User → Add User/Edit User → Authentication Mode . 3.
DS-K1T981 Series Access Control Terminal User Manual 7.4.1 Delete Data Delete user data. On the Home page, tap Data → Delete Data → User Data . All user data added in the device will be deleted. 7.4.2 Import Data Steps 1. Plug a USB flash drive in the device. 2. On the Home page, tap Data → Import Data . 3. Tap User Data, Face Data, Access Control Parameters or Iris Data. Note The imported access control parameters are configuration files of the device. 4.
DS-K1T981 Series Access Control Terminal User Manual 2. On the Home page, tap Data → Export Data . 3. Tap Face Data, Event Data, User Data, Access Control Parameters or Iris Data. Note The exported access control parameters are configuration files of the device. 4. Optional: Create a password for exporting. When you import those data to another device, you should enter the password. ● ● ● ● Note The supported USB flash drive format is DB.
DS-K1T981 Series Access Control Terminal User Manual Note Authentication via QR code should be supported by the device. Password Enter the password to authenticate via password. If authentication completed, a prompt "Authenticated" will pop up. 7.5.2 Authenticate via Multiple Credential Before You Start Set the user authentication type before authentication. For details, see Set Authentication Mode . Steps 1.
DS-K1T981 Series Access Control Terminal User Manual Figure 7-11 Basic Settings Page Shortcut Key Choose the shortcut key that displayed on the authentication page, including the QR code function, the call function, call type, and the password entering function. Note You can select call type from Call Room, Call Center, Call Specified Room No. and Call APP. Call Room When you tap the call button on the authentication page, you should dial a room No. to call.
DS-K1T981 Series Access Control Terminal User Manual Note You can set the voice volume between 0 and 10. Time Settings Set the time zone, the device time and the DST. Sleeping (s) Set the device sleeping waiting time (minute). When you are on the initial page and if you set the sleeping time to 30 min, the device will sleep after 30 min without any operation. Note If you set the sleeping time to 0, the device will not enter sleeping mode. Community No. Set the device installed community No. Building No.
DS-K1T981 Series Access Control Terminal User Manual Parameter Description Note You can input the number from 1 to 10. Wide Dynamic It is suggested to enable the WDR function if installing the device outdoors. When there are both very bright and very dark areas simultaneously in the view, you can enable the WDR function to balance the brightness of the whole image and provide clear images with details. Face 1:N Security Level Set the matching threshold when authenticating via 1:N matching mode.
DS-K1T981 Series Access Control Terminal User Manual Parameter Description Must Wear If the person do not wear the hard hat when authenticating, the device will pop up a prompt and the door will keep closed. None If the person do not wear the hard hat when authenticating, the device will not prompt a notification. Face with Mask Detection After enabling the face with mask detection, the system will recognize the captured face with mask picture.
DS-K1T981 Series Access Control Terminal User Manual Figure 7-13 Access Control Parameters The available parameters descriptions are as follows: Table 7-3 Access Control Parameters Descriptions Parameter Description Terminal Auth. Mode (Terminal Select the device's authentication mode. You can also customize Authentication Mode) the authentication mode. ● ● ● Note Only the device with the fingerprint module supports the fingerprint related function.
DS-K1T981 Series Access Control Terminal User Manual Parameter Description Open Duration Set the door unlocking duration. If the door is not opened for the set time, the door will be locked. Available door locked time range: 1 to 255 s. Authentication Interval Set the device authenticating interval. Available authentication interval range: 0 to 65535. 7.
DS-K1T981 Series Access Control Terminal User Manual Before You Start Add at least one user, and set the user's authentication mode. For details, see User Management. Steps 1. Tap T&A Status to enter the T&A Status page. 2. Set the Attendance Mode as Manual. Figure 7-15 Manual Attendance Mode 3. Enable the Attendance Status Required. 4. Enable a group of attendance status. Note The Attendance Property will not be changed. 5. Optional: Select an status and change its name if required.
DS-K1T981 Series Access Control Terminal User Manual Steps 1. Tap T&A Status to enter the T&A Status page. 2. Set the Attendance Mode as Auto. Figure 7-16 Auto Attendance Mode 3. Enable the Attendance Status function. 4. Enable a group of attendance status. Note The Attendance Property will not be changed. 5. Optional: Select an status and change its name if required. The name will be displayed on the T & A Status page and the authentication result page. 6. Set the status' schedule.
DS-K1T981 Series Access Control Terminal User Manual 7.9.4 Set Manual and Auto Attendance via Device Set the attendance mode as Manual and Auto, and the system will automatically change the attendance status according to the configured schedule. At the same time you can manually change the attendance status after the authentication. Before You Start Add at least one user, and set the user's authentication mode. For details, see User Management. Steps 1. Tap T&A Status to enter the T&A Status page. 2.
DS-K1T981 Series Access Control Terminal User Manual Note The attendance status will be valid within the configured schedule. Result On the initial page and authenticate. The authentication will be marked as the configured attendance status according to the schedule. If you tap the edit icon on the result tab, you can select a status to take attendance manually, the authentication will be marked as the edited attendance status.
DS-K1T981 Series Access Control Terminal User Manual Note The page may vary according to different device models. Refers to the actual page for details. Capacity You can view the number of user, face picture, card, event, fingerprint and iris. Upgrade Plug the USB flash drive in the device USB interface. Tap Upgrade → OK , and the device will read the digicap.dav file in the USB flash drive to start upgrading. Unlink APP Account Unlink the Hik-Connect account from the platform.
DS-K1T981 Series Access Control Terminal User Manual 1) Tap on the device initial page. 2) Enter 0 in the pop-up window. 3) Tap to call the client software. 6. Tap Answer on the pop-up page of the client software and you can start two-way audio between the device and the client software. Note If the device is added to multiple client softwares and when the device is calling the client software, only the first client software added the device will pop up the call receiving window. 7.11.
DS-K1T981 Series Access Control Terminal User Manual Note For details about adding device, see Add Device. 5. Enter the Live View page and double-click the added device to start live view. Note For details about operations in the Live View page, see Live View in the user manual of the client software. 6. Right click the live view image to open the right-click menu. 7. Click Start Two-Way Audio to start two-way audio between the device and the client software. 7.11.4 Call Room from Device Steps 1.
DS-K1T981 Series Access Control Terminal User Manual 1) Tap 2) Tap on the device initial page. to call the mobile client.
DS-K1T981 Series Access Control Terminal User Manual Chapter 8 Operation via Web Browser 8.1 Login You can login via the web browser. Note Make sure the device is activated. Obtain the IP address from the device after Wi-Fi is enabled. Make sure the IP segment of the device and the computer is the same. For details, refers to Set Wi-Fi Parameters . Enter the device IP address in the address bar of the web browser and press Enter to enter the login page. Enter the device user name and the password.
DS-K1T981 Series Access Control Terminal User Manual Select the image size when starting live view. Set the volume when starting live view. Note If you adjust the volume when starting two-way audio, you may hear a repeated sounds. You can capture image when starting live view. Reserved function. You can zoom in the live view image. Unlock the linked door. Start or stop live view. Start or stop video recording. Select the streaming type when starting live view.
DS-K1T981 Series Access Control Terminal User Manual Click Save to save the settings. Add Fingerprint Click User → Add to enter the Add Person page. Click Add Fingerprint, and press your finger on the fingerprint module of the device to add your fingerprint. Click Complete to save the settings. Add Iris Click User → Add to enter the Add Person page. Click Add, set the Adding Method and Iris Mode, and click + or Click OK to save the settings. to add the iris file.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-2 Search Event Enter the search conditions, including the event type, the employee ID, the name, the card No., the start time, and the end time, and click Search. The results will be displayed on the right panel. 8.5 Configuration 8.5.1 Set Local Parameters Set the live view parameters, record file size and saving path, and captured pictures and clip saving path. Set Live View Parameters Click Configuration → Local to enter the Local page.
DS-K1T981 Series Access Control Terminal User Manual 8.5.2 View Device Information View the device name, language, model, serial No., QR code, version, number of channels, alarm input, alarm output, lock and RS-485, device capacity, etc. Click Configuration → System → System Settings → Basic Information to enter the configuration page. You can view the device name, language, model, serial No., QR code, version, number of channels, alarm input, alarm output, lock and RS-485, device capacity, etc.
DS-K1T981 Series Access Control Terminal User Manual 2. Check Enable DST. 3. Set the DST start time, end time and bias time. 4. Click Save to save the settings. 8.5.5 View Open Source Software License Go to Configuration → System → System Settings → About , and click View Licenses to view the device license. 8.5.6 Upgrade and Maintenance Reboot device, restore device parameters, and upgrade device version. Reboot Device Click Configuration → System → Maintenance → Upgrade & Maintenance .
DS-K1T981 Series Access Control Terminal User Manual Default The device will restore to the default settings, except for the device IP address and the user information. Unlink APP Account Unlink the Hik-Connect account from the platform. Import and Export Parameters Click Configuration → System → Maintenance → Upgrade & Maintenance . Export Click Export to export the logs or device parameters. Note You can import the exported device parameters to another device. Import Click and select the file to import.
DS-K1T981 Series Access Control Terminal User Manual Select a security mode from the drop-down list, and click Save. Security Mode High security level for user information verification when logging in the client software. Compatible Mode The user information verification is compatible with the old client software version when logging in. Enable SSH To raise network security, disable SSH service. The configuration is only used to debug the device for the professionals.
DS-K1T981 Series Access Control Terminal User Manual Install Other Authorized Certificate If you already has an authorized certificate (not created by the device), you can import it to the device directly. Steps 1. Go to Configuration → System → Security → Certificate Management . 2. In the Import Passwords and Import Communication Certificate areas, select certificate type and upload certificate. 3. Click Install. Install CA Certificate Before You Start Prepare a CA certificate in advance. Steps 1.
DS-K1T981 Series Access Control Terminal User Manual Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user. 8.5.11 View Device Arming/Disarming Information View device arming type and arming IP address. Go to Configuration → User Management → Arming/Disarming Information . You can view the device arming/disarming information. Click Refresh to refresh the page. 8.5.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-5 TCP/IP Settings Page Set the parameters and click Save to save the settings. DHCP If uncheck the function, you should set the IPv4 address, IPv4 subnet mask and IPv4 default gateway. If you check the function, the system will allocate the IPv4 address, IPv4 subnet mask and the IPv4 default gateway automatically. NIC Type Select a NIC type from the drop-down list. By default, it is Auto.
DS-K1T981 Series Access Control Terminal User Manual DNS Server Set the preferred DNS server and the Alternate DNS server according to your actual need. Set Port Parameters Set the HTTP, RTSP, HTTPS and Server port parmaeters. Click Configuration → Network → Basic Settings → Port . HTTP It refers to the port through which the browser accesses the device. For example, when the HTTP Port is modified to 81, you need to enter http://192.0.0.65:81 in the browser for login.
DS-K1T981 Series Access Control Terminal User Manual 2) Set the IP address, subnet mask, and default gateway. Or check Enable DHCP and the system will allocate the IP address, subnet mask, and default gateway automatically. 5. Click Save. Report Strategy Settings You can set the center group for uploading the log via the ISUP protocol. Go to Configuration → Network → Basic Settings → Report Strategy . You can set the center group and the system will transfer logs via ISUP protocol.
DS-K1T981 Series Access Control Terminal User Manual Note Hik-Connect is an application for mobile devices. With the App, you can view live image of the device, receive alarm notification and so on. 3. Check the checkbox of Enable to enable the function. 4. Optional: Check the checkbox of Custom, and you can set the server address by yourself. 5. Create a Stream Encryption/Encryption Key for the device. Note 6 to 12 letters (a to z, A to Z) or numbers (0 to 9), case sensitive.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-7 Video Settings Page Set the video channel, the stream type, the video type, resolution, the bitrate type, video quality, the frame rate, the Max. bitrate, the video encoding, and I frame interval. Click Save to save the settings after the configuration. Set Audio Parameters Click Configuration → Video/Audio → Audio .
DS-K1T981 Series Access Control Terminal User Manual Figure 8-8 Set Audio Parameters Drag the block to adjust the device input and output volume. Click Save to save the settings after the configuration. You can also enable Voice Prompt. Note The functions vary according to different models. Refers to the actual device for details. 8.5.14 Customize Audio Content Customize the output audio content when authentication succeeded and failed. Steps 1. Click Configuration → Video/Audio → Prompt .
DS-K1T981 Series Access Control Terminal User Manual Figure 8-9 Customize Audio Content 2. Set the appellation. 3. Enable the function. 4. Set the time duration when authentication succeeded. 1) Click Add. 2) Set the time duration and the language. Note If authentication is succeeded in the configured time duration, the device will broadcast the configured content. 3) Enter the audio content. 4) Optional: Repeat substep 1 to 3. 5) Optional: Click to delete the configured time duration. 5.
DS-K1T981 Series Access Control Terminal User Manual 2) Select the importing path, and click Import. 7. Click Save to save the settings. 8.5.15 Set Image Parameters Set the video standard, WDR, brightness, contrast, and saturation. Steps 1. Click Configuration → Image Adjustment . 2. Configure the parameters to adjust the image. Video Standard Set the video frame rate when performing live view remotely. After changing the standard, you should reboot the device to take effect. PAL 25 frames per second.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-10 Supplement Light Settings Page 2. Select a supplement light type and mode from the drop-down list. If you select the mode as ON, you should set the LED light brightness. 8.5.
DS-K1T981 Series Access Control Terminal User Manual 3. Optional: Edit Schedule Name according to the actual needs. 4. Drag mouse to set the schedule. Note Set the schedule from Monday to Sunday according to the actual needs. 5. Optional: Select a timeline and click Delete. Or click Delete All to clear the settings. 6. Click Save. Set Manual Attendance via Web Set the attendance mode as manual, and you should select a status manually when you take attendance.
DS-K1T981 Series Access Control Terminal User Manual 3. Enable the Attendance Status function. 4. Enable a group of attendance status. Note The Attendance Property will not be changed. 5. Optional: Select an status and change its name if required. 6. Set the status' schedule. Refers to Time Settings for details. Set Manual and Auto Attendance via Web Set the attendance mode as Manual and Auto, and the system will automatically change the attendance status according to the configured schedule.
DS-K1T981 Series Access Control Terminal User Manual Note The functions vary according to different models. Refers to the actual device for details. Click Save to save the settings after the configuration. Card Reader Select Main Card Reader or Sub Card Reader from the drop-down list. Main Card Reader You can configure the device card reader's parameters. Sub Card Reader You can configure the connected peripheral card reader's parameters.
DS-K1T981 Series Access Control Terminal User Manual Authentication Select an authentication mode according to your actual needs from the drop-down list. Recognition Interval If the interval between card presenting of the same card is less than the configured value, the card presenting is invalid. Authentication Interval You can set the authentication interval of the same person when authenticating. The same person can only authenticate once in the configured interval.
DS-K1T981 Series Access Control Terminal User Manual Delete Old Events by Specified Time Set a time and all events will be deleted on the configured time. Overwriting The earliest 5% events will be deleted when the system detects the stored events has been over 95% of the full space. Authentication Settings Display Authentication Result You can check Face Picture, Name, and Employee ID, to display the authentication result.
DS-K1T981 Series Access Control Terminal User Manual All registered pictures in the device will be deleted. Clear Captured Pictures All captured pictures in the device will be deleted. Set Face Recognition Parameters You can set face recognition parameters for accessing. Click Configuration → Access Control → Face Recognition Parameters . You can set Working Mode as Access Control Mode. The access control mode is the device normal mode. You should authenticate your credential for accessing.
DS-K1T981 Series Access Control Terminal User Manual After enable the DESFire card content reading function, the device can read the DESFire card content. Enable FeliCa Card The device can read the data from FeliCa card when enabling the FeliCa card function. Set Card Authentication Parameters Set the card reading content when authenticate via card on the device. Go to Configuration → General → Card Authentication Settings . Select a card authentication mode and click Save. Full Card No. All card No.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-11 Device No. Settings Device Type The device can be used as a door station or outer door station. Select a device type from the drop-down list. Note If you change the device type, you should reboot the device. Floor No. Set the device installed floor No. Door Station No. Set the device installed floor No. ● ● Note If you change the No., you should reboot the device. The main door station No. is 0, and the sub door station No.
DS-K1T981 Series Access Control Terminal User Manual Set the device building No. Unit No. Set the device unit No. Note If you change the No., you should reboot the device. If set the device type as Outer Door Station, you can set the period No., outer door station No., and community No. Outer Door Station No. If you select outer door station as the device type, you should enter a number between 1 and 99. Note If you change the No., you should reboot the device. Phase No. Set the device phase No.
DS-K1T981 Series Access Control Terminal User Manual Note If you check Call Management Center and set the call No. as well, call management center has higher privilege than call No. 8.5.20 Access Control Settings Set Door Parameters Click Configuration → Access Control → Door Parameters . Figure 8-12 Door Parameters Settings Page Click Save to save the settings after the configuration. Door No. Select the device corresponded door No. Name You can create a name for the door.
DS-K1T981 Series Access Control Terminal User Manual Open Duration Set the door unlocking duration. If the door is not opened for the set time, the door will be locked. Door Open Timeout Alarm An alarm will be triggered if the door has not been closed within the configured time duration. Door Contact You can set the door contact as Remain Open or Remain Closed according to your actual needs. By default, it is Remain Closed.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-13 RS-485 Page Check Enable RS-485, and set the parameters. Click Save to save the settings after the configuration. No. Set the RS-485 No. Peripheral Type Select a peripheral from the drop-down list according the actual situation. You can select from Card Reader, Extension Module, Access Controller, or Disable. Note After the peripheral is changed and saved, the device will reboot automatically.
DS-K1T981 Series Access Control Terminal User Manual Note If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address according to the door No. Baud Rate The baud rate when the devices are communicating via the RS-485 protocol. Output Type If you select Access Controller as the peripheral type, you should set the parameter. The device will output the card No.
DS-K1T981 Series Access Control Terminal User Manual 4. Click Save to save the settings. Note If you change the peripheral, and after you save the device parameters, the device will reboot automatically. 8.5.21 Iris Settings Steps 1. Click Configuration → Smart → Smart . 2. Set card reader type. 3. Drag the block to adjust the iris recognition interval and iris 1:N security level. Iris Recognition Interval The time interval between two continuous face recognitions when authenticating.
DS-K1T981 Series Access Control Terminal User Manual Figure 8-15 Smart Settings Page Click Save to save the settings after the configuration. Face Anti-spoofing Enable or disable the live face detection function. If enabling the function, the device can recognize whether the person is a live one or not.
DS-K1T981 Series Access Control Terminal User Manual Note Biometric recognition products are not 100% applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes. Live Face Detection Security Level After enabling the face anti-spoofing function, you can set the matching security level when performing live face authentication. Recognition Distance Select the distance between the authenticating user and the device camera.
DS-K1T981 Series Access Control Terminal User Manual Set the matching threshold when authenticating via 1:1 matching mode. The larger the value, the smaller the false accept rate and the larger the false rejection rate. 1:N Matching Threshold Set the matching threshold when authenticating via 1:N matching mode. The larger the value, the smaller the false accept rate and the larger the false rejection rate. Face Recognition Timeout Value Set the timeout value when face recognizing.
DS-K1T981 Series Access Control Terminal User Manual If the person do not wear a face mask when authenticating, the device prompts a notification and the door will open. Must Wear If the person do not wear a face mask when authenticating, the device prompts a notification and the door keeps closed. Face with Mask 1:N Matching Threshold Set the matching threshold when authenticating with face mask via 1:N matching mode.
DS-K1T981 Series Access Control Terminal User Manual You can click + in the frame and upload the screen saver pictures from the local PC. Note By now, there is only one theme can be added. Play Schedule After you have created a theme, you can select the theme and draw a schedule on the time line. Select the drawn schedule and you can edit the exact start and end time. Select the drawn schedule and you can click Delete or Delete All to delete the schedule.
DS-K1T981 Series Access Control Terminal User Manual Chapter 9 Client Software Configuration 9.1 Configuration Flow of Client Software Follow the flow diagram below to configure on the client software. Figure 9-1 Flow Diagram of Configuration on Client Software 9.2 Device Management The client supports managing access control devices and video intercom devices.
DS-K1T981 Series Access Control Terminal User Manual 9.2.1 Add Device The client provides three device adding modes including by IP/domain, IP segment, and ISUP protocol. The client also supports importing multiple devices in a batch when there are large amount of devices to be added. Add Device by IP Address or Domain Name If you know the IP address or domain name of the device to add, you can add devices to the client by specifying the IP address (or domain name), user name, password, etc. Steps 1.
DS-K1T981 Series Access Control Terminal User Manual Note ● This function should be supported by the device. ● If you have enabled Certificate Verification, you should click Open Certificate Directory to open the default folder, and copy the certificate file exported from the device to this default directory to strengthen the security. See for details about enabling certificate verification. ● You can log into the device to get the certificate file by web browser. 6.
DS-K1T981 Series Access Control Terminal User Manual Enter the device user name. By default, the user name is admin. Password Enter the device password. Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
DS-K1T981 Series Access Control Terminal User Manual characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user. 9.2.
DS-K1T981 Series Access Control Terminal User Manual Example For example, on the 1st floor, there mounted 16 doors, 64 alarm inputs, and 16 alarm outputs. You can organize these resources into one group (named 1st Floor) for convenient management. You can control door status, and do some other operations of the devices after managing the resources by groups. 9.3.1 Add Group You can add group to organize the added device for convenient management. Steps 1. Enter the Device Management module. 2.
DS-K1T981 Series Access Control Terminal User Manual 9.4 Person Management You can add person information to the system for further operations such as access control, video intercom, time and attendance, etc. You can manage the added persons such as issuing cards to them in a batch, importing and exporting person information in a batch, etc. 9.4.1 Add Organization You can add an organization and import person information to the organization for effective management of the persons.
DS-K1T981 Series Access Control Terminal User Manual Import Person Information You can enter the information of multiple persons in a predefined template (CSV/Excel file) to import the information to the client in a batch. Steps 1. Enter the Person module. 2. Select an added organization in the list, or click Add in the upper-left corner to add an organization and then select it. 3. Click Import to open the Import panel. 4. Select Person Information as the importing mode. 5.
DS-K1T981 Series Access Control Terminal User Manual Note ● The (folder of) face pictures should be in ZIP format. ● Each picture file should be in JPG format and should be no larger than 200 KB. ● Each picture file should be named as "Person ID_Name". The Person ID should be the same with that of the imported person information. 6. Click Import to start importing. The importing progress and result will be displayed.
DS-K1T981 Series Access Control Terminal User Manual ● ● Note The exported file is in ZIP format. The exported face picture is named as "Person ID_Name_0" ("0" is for a full-frontal face). 9.4.3 Get Person Information from Access Control Device If the access control device has been configured with person information (including person details, fingerprint, and issued card information), you can get the person information from the added device and import them to the client for further operations.
DS-K1T981 Series Access Control Terminal User Manual 9.4.4 Issue Cards to Persons in Batch The client provides a convenient way to issue cards to multiple persons in a batch. Steps 1. Enter Person module. 2. Click Batch Issue Cards. All the added persons with no card issued will be displayed in the right panel. 3. Optional: Enter key words (name or person ID) in the input box to filter the person(s) that need issuing cards. 4. Optional: Click Settings to set the card issuing parameters.
DS-K1T981 Series Access Control Terminal User Manual the card number. If not, you can also swipe the card on the card reader of the added access control device to get the card number. As a result, before issuing a card to one person, you need to set the card issuing parameters including the issuing mode and related parameters. When adding a card to one person, click Settings to open the Card Issuing Settings window.
DS-K1T981 Series Access Control Terminal User Manual Note For access group settings, refer to Set Access Group to Assign Access Authorization to Persons . 9.5.1 Add Holiday You can create holidays and set the days in the holidays, including start date, end date, and holiday duration in one day. Steps Note You can add up to 64 holidays in the software system. 1. Click Access Control → Schedule → Holiday to enter the Holiday page. 2. Click Add on the left panel. 3. Create a name for the holiday. 4.
DS-K1T981 Series Access Control Terminal User Manual 9.5.2 Add Template Template includes week schedule and holiday. You can set week schedule and assign the time duration of access authorization for different person or group. You can also select the added holiday(s) for the template. Steps Note You can add up to 255 templates in the software system. 1. Click Access Control → Schedule → Template to enter the Template page.
DS-K1T981 Series Access Control Terminal User Manual 3) Optional: Click Add to add a new holiday. Note For details about adding a holiday, refer to Add Holiday . 4) Optional: Select a selected holiday in the right list and click click Clear to clear all the selected holiday(s) in the right list. 7. Click Save to save the settings and finish adding the template. to remove the selected one, or 9.
DS-K1T981 Series Access Control Terminal User Manual Figure 9-2 Display the Selected Person(s) and Access Point(s) 8. After adding the access groups, you need to apply them to the access control device to take effect. 1) Select the access group(s) to apply to the access control device. 2) Click Apply All to Devices start applying all the selected access group(s) to the access control device or door station. 3) Click Apply All to Devices or Apply Changes to Devices.
DS-K1T981 Series Access Control Terminal User Manual You can click the prompt to apply the changed data to the device. You can select either Apply Now or Apply Later. Figure 9-3 Data Synchronization 9.7 Configure Advanced Functions You can configure the advanced functions of access control to meet some special requirements in different scene, such as multi-factor authentication, anti-passback, etc.
DS-K1T981 Series Access Control Terminal User Manual Note If you can not find Device Parameter in the Advanced Function list, hover the cursor on the Advanced Function, and then Click to select the Device Parameter to be displayed. 2. Select an access device to show its parameters on the right page. 3. Turn the switch to ON to enable the corresponding functions. ● ● Note The displayed parameters may vary for different access control devices.
DS-K1T981 Series Access Control Terminal User Manual 4. Click OK. 5. Optional: Click Copy to, and then select the access control device(s) to copy the parameters in the page to the selected device(s). Configure Parameters for Door/Elevator After adding the access control device, you can configure its access point (door or floor) parameters. Before You Start Add access control device to the client. Steps 1. Click Access Control → Advanced Function → Device Parameter . 2.
DS-K1T981 Series Access Control Terminal User Manual The door can be locked once it is closed even if the Door Locked Time is not reached. Duress Code The door can open by inputting the duress code when there is duress. At the same time, the client can report the duress event. Super Password The specific person can open the door by inputting the super password. Dismiss Code Create a dismiss code which can be used to stop the buzzer of the card reader (by entering the dismiss code on the keypad).
DS-K1T981 Series Access Control Terminal User Manual Name Edit the card reader name as desired. OK LED Polarity/Error LED Polarity/Buzzer Polarity Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the card reader parameters. Generally, adopts the default settings. Minimum Card Swiping Interval If the interval between card swiping of the same card is less than the set value, the card swiping is invalid. You can set it as 0 to 255. Max.
DS-K1T981 Series Access Control Terminal User Manual Face Recognition Timeout Value If the recognition time is more than the configured time, the device will remind you. Face Recognition Interval The time interval between two continuous face recognitions when authenticating. By default, it is 2s. Face 1:1 Matching Threshold Set the matching threshold when authenticating via 1:1 matching mode. The larger the value, the smaller the false accept rate and the larger the false rejection rate when authentication.
DS-K1T981 Series Access Control Terminal User Manual Before You Start Add access control device to the client, and make sure the device supports alarm output. Steps 1. Click Access Control → Advanced Function → Device Parameter to enter access control parameter configuration page. 2. In the device list on the left, click to expand the door, select an alarm input and you can edit the alarm input's parameters on the right. 3. Set the alarm output parameters. Name Edit the card reader name as desired.
DS-K1T981 Series Access Control Terminal User Manual Set the barrier's opening and closing speed. You can select from 1 to 10. The greater the value, the faster the speed. Note The recommended value is 6. Audible Prompt Duration Set how long the audio will last, which is played when an alarm is triggered . Note 0 refers to the alarm audio will be played until the alarm is ended. Temperature Unit Select the temperature unit that displayed in the device status. 4. Click OK. 9.7.
DS-K1T981 Series Access Control Terminal User Manual select Deep Learning as the face picture database. Authenticate by QR Code If enabled, the device camera can scan the QR code to authenticate. By default, the function is disabled. Blocklist Authentication If enabled, the device will compare the person who want to access with the persons in the blocklist. If matched (the person is in the blocklist), the access will be denied and the device will upload an alarm to the client.
DS-K1T981 Series Access Control Terminal User Manual Set Wiegand Parameters You can set the access control device's Wiegand channel and the communication mode. After setting the Wiegand parameters, the device can connect to Wiegand card reader via Wiegand communication. Before You Start Add access control device to the client, and make sure the device supports Wiegand. Steps 1. Enter the Access Control module. 2. On the navigation bar on the left, enter Advanced Function → More Parameters . 3.
DS-K1T981 Series Access Control Terminal User Manual 9.8 Door/Elevator Control In Monitoring module, you can view the real-time status of the doors or elevators managed by the added access control device. You can also control the doors and elevators such as open/close the door, or remain the door open/closed via the client remotely. The real-time access event are displayed in this module. You can view the access details and person details.
DS-K1T981 Series Access Control Terminal User Manual When the door is unlocked, lock it and it will be closed. The person who has the access authorization can access the door with credentials. Remain Unlocked The door will be unlocked (no matter closed or open). All the persons can access the door with no credentials required. Remain Locked The door will be closed and locked. No person can access the door even if he/she has the authorized credentials, except the super users.
DS-K1T981 Series Access Control Terminal User Manual Figure 9-4 Real-time Access Records Note You can right click the column name of access event table to show or hide the column according to actual needs. 2. Optional: Select an access point group from the drop-down list in the upper-right corner to show the real time access records of the selected group. 3. Optional: Check the event type and event status. The detected events of checked type and status will be displayed in the list below. 4.
DS-K1T981 Series Access Control Terminal User Manual Appendix A. Tips for Scanning Fingerprint Recommended Finger Forefinger, middle finger or the third finger. Correct Scanning The figure displayed below is the correct way to scan your finger: You should press your finger on the scanner horizontally. The center of your scanned finger should align with the scanner center.
DS-K1T981 Series Access Control Terminal User Manual Others If your fingerprint is shallow, or it is hard to scan your fingerprint, we recommend you to use other authentication methods. If you have injuries on the scanned finger, the scanner may not recognize. You can change another finger and try again.
DS-K1T981 Series Access Control Terminal User Manual Appendix B. Tips When Collecting/Comparing Face Picture The position when collecting or comparing face picture is as below: Positions (Recommended Distance: 0.5 m) Expression ● ● ● Keep your expression naturally when collecting or comparing face pictures, just like the expression in the picture below. Do not wear hat, sunglasses, or other accessories that can affect the facial recognition function. Do not make your hair cover your eyes, ears, etc.
DS-K1T981 Series Access Control Terminal User Manual 142
DS-K1T981 Series Access Control Terminal User Manual Appendix C. Tips for Installation Environment 1. Light Source Illumination Reference Value Candle: 10Lux Bulb: 100~850Lux Sunlight: More than 1200Lux 2.
DS-K1T981 Series Access Control Terminal User Manual Appendix D.
DS-K1T981 Series Access Control Terminal User Manual Appendix E. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure E-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands.
UD24933B