Quick Start Guide

1
2
3
3
AIN8
AIN7
AIN6
AIN5
AIN4
AIN3
AIN2
AIN1
GND
GND
RS485-
RS485+
COM2
NO2
COM1
NO1
Alarm TerminalsRS485/Relay Interface
122
1.5
Unit:mm
105.5
92
Rear Panel (without Interface)
Screw
Wall Mounng Plate Gang Box Wall
Lock Catch Lock Catch
Lock Catch Lock Catch
Hook
Hook
Hook
Hook
Rear Panel (without Interface)
Screw
Wall Mounng Plate Gang Box
Wall
Lock Catch Lock Catch
Lock Catch Lock Catch
Hook
Hook
Hook
Hook
Note: If you use the gang box (55 mm (width) × 101 mm (length) × 38.5 mm (depth)) to install, you should set the screws to le and right screw holes.
Note: If you use the gang box (75 mm (width) × 75 mm (length) × 46 mm (depth)) to install, you should set the screws to up and down screw holes.
Scan the QR code to get the
configuraon guide for detailed
informaon.
Scan the QR code to get the
operaon guide for detailed
informaon.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
1
2
3
7 8
54
9
10
11
6
12
DS-KH9510-WTE1
Android Indoor Staon
Diagram References
ENGLISH
Refer to Video Intercom Network Indoor Staon Configuraon Guide (scan the QR code) for details.
Refer to Video Intercom Network Indoor Staon Operaon Guide (scan the QR code) for details.
UD19191B
Appearance
Installaon
1
3
Terminal
2
Screen Microphone Unlock Buon
1 2 3 4
5 6 7
Before you begin:
Make sure the device in the package is in good condition and all the assembly parts are included.
The indoor station power supply is 12 VDC. Ensure your power supply matches your indoor station.
Make sure all related equipment is powered-off during the installation.
Check the product specification for the installation environment.
Wall Mounting with Gang Box
The wall mounting plate and the gang box are required to install the indoor station onto the wall.
There are two sizes of gang boxes adapted to the device.
Size 1: 75 mm (width) × 75 mm (length) × 46 mm (depth)
Size 2: 55 mm (width) × 101 mm (length) × 38.5 mm (depth)
1. Cave a hole in the wall.
Note: The suggested dimension of the installation hole should be larger than the gang box.
2. Insert a gang box to the hole chiseled on the wall.
3. Fix the wall mounting plate to the gang box with two screws.
Notes
If you install the device with a gang box (75 mm (width) × 75 mm (length) × 46 mm (depth)), the upper and lower
holes will apply.
If you install the device with a gang box (55 mm (width) × 101 mm (length) × 38.5 mm (depth)), the upper and lower
holes will apply.
4. Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks into the slots of
the rear panel of the indoor station, during which the lock catch will lock automatically.
Mounng Accessories
RS-485/Relay Interface
Power Supply Interface
Alarm Terminals
9 10 Reserved 11 TAMPERLoudspeaker
AIN1: Alarm Input 1
AIN2: Alarm Input 2
AIN3: Alarm Input 3
AIN4: Alarm Input 4
NO1/NO2: Normally Open
COM1/COM2: Common Interface
RS485-/RS485+: RS-485 Communicaon Interface
AIN5: Alarm Input 5
AIN6: Alarm Input 6
AIN7: Alarm Input 7
AIN8: Alarm Input 8
GND: Grounding
Note: The appearance of the device varies by model. Refers to the actual device for detailed information.
Note: For wiring description, refer to the user manual.
Acvate Indoor Staon
Geng Started
4
1. Choose Language and tap Next.
2. Set network parameters and tap Next.
- Edit Local IP, Subnet Mask, and Gateway parameters.
- Enable DHCP, the device will get network parameters automatically.
3. Configure the indoor station and tap Next.
a. Select Indoor Station Type.
b. Edit Floor and Room No.
4. Linked related devices and tap Next. If the device and the indoor station are in the
same LAN, the device will be displayed in the list. Tap the device or enter the serial
no. to link.
a. Tap the door station in the list to link.
b. Tap the settings icon to pop up the Network Settings page.
c. Edit the network parameters of the door station manually or enable DHCP to get
1. Power on the device. It will enter the acvaon page automacally.
2. Create a password and confirm it.
3. Tap OK to acvate the indoor staon.
You are required to acvate the device first by seng a strong password before
you can use the device.
1
Quick Configuraon
2
the network parameters automatically.
d. Optional: Enable Synchronize Language to synchronize the language of door
station with indoor station.
e. Tap OK to save the settings.
5. Tap Finish to save the settings.
The power supply must conform to LPS. The recommended adapter models and
manufacturers are shown as below. Use the attached adapter, and do not change
the adapter randomly.
Model Current Manufacturer Standard
MSA-C1500IC12.0-18P -US 1.5 A MOSO POWER SUPPLY TECHNOLOGY CO.,LTD PG
TS-A018-120015AD 1.5 A SHENZHEN TRANSIN TECHNOLOGIES CO.,LTD PG
Debugging Port 8 MicroUSB Interface