User's Manual
Hybrid Security Control Panel
ENGLISH
Diagram References
Wiring and Installaon
Set up via iVMS-4200 Client Soware
Set up via APP
Configure Video-Push
Log Into the Web Client
1. Download and install the iVMS-4200 client soware.
Note: Get the client soware from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit
Network Sengs, change the port as 80, and click Add to Client.
Note: You should acvate the device for the first usage.
Set Up
1
2
Set up via Web Client
Input the device IP address in the address bar of the web browser. Create a password to
acvate the device and log into the web client.
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connecng the network cable with computer directly :192.0.0.64
1. Unlock the front cover with the supplied key, open the case of the control panel.
2. Fix the control panel case on the required place with three supplied screws.
6. Close the case of the control panel. Lock the front cover with the supplied key.
1. Log into the App Store and input Hik-Connect to search and install the mobile client.
2. Log into the APP with Hik-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel (on the lable).
4. Tap Connect to a Network. Select Wireless Connecon (AP) as the connecon mode.
5. Push the AP/STA mode switch to the AP posion, tap Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi, and
click Next.
7. Create a password to acvate the device.
8. Push the AP/STA mode switch to the STA posion.
Note: You need to enter the Verificaon Code (on the device lable which is pasted on the rear panel) before
acvaon if you add the device by entering the device serial No.(SN).
You can view the alarm video via APP and email. For detailed sengs, refer to Security
Control Panel User Manual.
Specification
2
1
23
2
4
2
5
2
1
2
2
25 2
8
2
3
......
AP STA AP STA
21
2
3
4
Alarm Input/Alarm Output/RS-485/Power Supply Wiring
Alarm Input Wiring
22
a.
Alarm Output Wiring
2
3
RS-485 Wiring: Wireless Receiver, keypad, etc.
2
4
Power Supply Wiring
Telephone Module Wiring
Network Wiring
1
Antenna Wiring (Wi-Fi and 3G/4G/GPRS Antenna)
1. Connect the pin of the pedestal to the terminal on the board or module.
2. Rotate and fix the antenna on the pedestal.
NC Detector
b.
c.
NO Detector
Unoccupied Zone
Power down the control panel before connecng and disconnecng accessories
and peripherals.
3. Fix the SIM card module (Sold separately) with four plasc bolts.
4. Install the telephone module (Sold separately) with two plasc bolts.
5. Wire the cables.
The AP mode is only Supported by device with Wi-Fi funcon.
1. Click System-Network Camera, and you can add cameras for the control panel.
2. Enter the “Device Management” page, select a zone, and select a camera to link with the
zone.
You can also link a camera with the zone via APP, refer to the Security Control Panel User
Manual for details.
The funcon varies depending on the model of device.
Add a Camera for the Zone
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings, pictures, graphs are the properes of
Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinaer referred to be
“Hikvision”). This user manual (hereinaer referred to be “the Manual”) cannot be reproduced,
changed, translated, or distributed, parally or wholly, by any means, without the prior wrien
permission of Hikvision. Unless otherwise spulated, Hikvision does not make any warranes,
guarantees or representaons, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to the Axiom Security Control Panel Kit.
The Manual includes instrucons for using and managing the product. Pictures, charts, images and all
other informaon hereinaer are for descripon and explanaon only. The informaon contained in the
Manual is subject to change, without noce, due to firmware updates or other reasons. Please find the
latest version in the company website (hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the
properes of Hikvision in various jurisdicons. Other trademarks and logos menoned below are the
properes of their respecve owners.
This product and - if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the RE
Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the LVD Direcve 2014/35/EU, the
RoHS Direcve 2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of
as unsorted municipal waste in the European Union. See the product documentaon for
specific baery informaon. The baery is marked with this symbol, which may include
leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the baery to your supplier or to a designated collecon point. For more informaon
see:www.recyclethis.info
Product Informaon
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause
harmful interference to radio or television recepon, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operaon
1
2
2
1
Dry Contact
AUX+AUX- D- D+
AUX+
AUX-
OR
DC- DC+
D-
D+
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
Alarm
Lamp
Alarm
Lamp
Alarm
Lamp
Alarm
Lamp
Siren
RS-485
Lead-acid
Battery
15VDC
Power Adapter
Z1 C Z2 Z3 C Z4 Z5 C Z6 Z7 C Z8 C1 PGM1 AUX+ BELL+ D+ DC+ BAT+C2 PGM2 C3 PGM3 C4 PGM4 AUX BELL D BATDC
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
Only for device with
8 on-board zones
Only for device with
8 on-board zones
C1 PGM1
……
2
2
2
3
2
4
CAUTION
SUITABLE FOR MOUNTING ON
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
CAUTION
COPER OR COPER WIRE CANNOT BE
EXPOSED AT THE ELECTRICAL TERMINAL
4
GPRS
Wi-Fi
3G/4G
CN1
MAIN
AUX
Telephone Module
Telephone Line Cut Off Indicator
Power Indicator
Telephone
Line
Telephone
Line
Telephone
Telephone
Set up via APP
2a
2
b
2
c 2d
2.2KΩ
NC
C
Z
C
Peripheral Security Detector
2.2KΩ
NO
C
Z
C
Security Control Panel
Security Control Panel
Security Control Panel
Peripheral Security Detector
Z
C
2.2K Ω
2.2K Ω
Z
C
D E T E C T OR
NC
NO
TAMPER
d.
Tamper-proof
Note:
The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9.
The products do not contain the PSTN, 2G, 3G, or 4G funcon, but support the extension module for PSTN, 2G, 3G and 4G.
AP STA AP STA
UD15862B
Wireless Detector
Wireless Output expander
Siren
Keyfob
Partition
Zone
A
larm output Alarm output
Scheduled arming/disarming
SMS notification
(with 3G/4G/GPRS module)
Network camera accessing
Application
Protocol
Wired network
Cellular Network
(with 3G/4G/GPRS module)
Standard
Encryption
Configuration
Distance
TAMPER Switch
Network Interface
Telephone Interface
RS-485 Terminal
Siren Power Interface
Battery Interface
User
Tag
Operation Temperature
Operation Humidity
Dimension (W × H × D)
8
on-board zones, and 56 wired/wireless zones expadable
8
DS-PHA64-W4M
8
02.11b/g/n
6
4/128-bit WEP,WPA/
W
PA2,WPA-PSK/WPA2-
P
SK,WPS
AP Mode
4
10M/100M Ethernet
I
SAPI: Supports client software and web client
C
loud P2P: Supports cloud P2P privacy protocol
DC09: ARC accessible (CID/SIA)
iVMS-4200 (client software)
Hik-Connect (mobile client)
S
upports up to 8 mobile phone numbers
Supported
4 on-board outputs, and 60 wired/wireless outputs expadable
1, 12V
1
, extended up to 64 inputs/outputs (with RS-485 module),
a
nd 9 wired keypads extendable
1, PSTN expander interface
1, RJ45 10M/100M Ethernet Interface
1, front cover tamper-proof
S
upports report push- notification to ARC & Cloud
I
ndoor: ≤ 50 m
O
utdoor: ≤ 100 m
Metal Case: 351.4 mm (13.8") × 261.4 mm (10.3") × 93.3 mm (3.7")
10% to 90% (No condensing)
–10 °C to 55 °C (-4 °F to +122 °F)
12
I
nstaller: 1
A
dministrator: 1
M
anufactuer:1
O
perator: 45
Storage battery (-M model)
U
ser
O
thers
W
i-Fi
I
nterface &
C
omponent
A
pplication &
P
rotocol
N
etwork
A
larm input
Model
Hybrid Security Control Panel with Metal Case
D
evice
c
onnection
Up to 56
Up to 8
1
wired siren (on-board connection)
2 wireless sirens