User's Manual
ENGLISH
Diagram References
Appearance
Wiring and Installaon
Set up via 4200 Client
Restore Default Sengs
Set up via APP
Add a Camera for the Zone
Configure Video-Push
Log Into the Web Client
1. Download and install the iVMS-4200 client.
Note: Get the client soware from the official website:www.hikvision.com.
2. Enter Device Management page, select the device in the Online Device List, click Edit
Network Sengs, change the port as 80, and click Add to Client.
Note: You should acvate the device for the first usage.
Set Up
1
2
3
Set up via Web Client
Input the device IP address in the address bar of the web browser. Create a password to
acvate the device and log into the web client.
Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device must be in the AP mode.
Default IP Address when connecng the network cable with computer directly :192.0.0.64
AC Power
Power On
System Fault
No Fault
Panel is added to Hik-connect account
Panel is not added to Hik-connect account
Armed
Disarmed
Alarm Occurred
Indicators Components
Device Tampered
No Alarm
Power Off
Fault
Link
Arm/Disarm
Alarm
Note: Remove the rear cover, and some of the components and interfaces are on the rear panel.
1
2
2
2
3
5
4
1. Loosen the screw on the top, press the lock nut, and open the case of the control panel.
2. Route the cables, and secure the rear cover in the installaon posion with the supplied
screws.
3. Fix the SIM card module (should be purchased separately) with four plasc bolts.
4. Fix the telephone module (should be purchased separately) with two plasc bolts.
5. Wire the cables .
1. Log into the App Store or Google Play and input Hik-Connect to search and install the
mobile client.
2. Log into the APP with Hik-Connect account.
3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).
4. Tap Connect to a Network. Select Wireless Connecon (AP) as the connecon mode.
5. Push the AP/STA mode switch to the AP posion, tab Confirm.
6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi , and
click Next.
7. Create a password to acvate the device.
8. Push the AP/STA mode switch to the STA posion.
Note: You need to enter the Verificaon Code (on the device lable which is pasted on the rear panel) before
acvaon if you add the device by entering the device serial No.(SN).
Baery
Connector
Network
Interface
Power
Interface
Lock Nut
AP&STA
Switch
TAMPER
Switch
Wiring
Terminal
2
12
2
13
2
11
Reset
Buon
2
10
2
9
2
8
2
7
2
6
You can view the alarm video via APP and email. For detailed sengs, refer to Security
Control Panel User Manual.
Reboot the device. Boot the device, and hold the reset buon for 5s aer the Fault indictaor
flashes 3 mes. The device will prompt a message to indicates the operaon status.
TAMPER Screw
It is compulsory to secure the TAMPER screw.
Specification
3
2
1 2
21 22
2
5
2
6
2
8
2
7
2
3 24
212
213
2
11
2
10
2827
2
6
2
1 22 23 24 25
29
25 2
8
CAUTION
RISK OF EXPLOSION IF
BATTERY IS REPLACED BY AN
INCORRECT TYPE
DISPOSE OF USED BATTERIES
ACCORDING TO THE
INSTRUCTIONS
CAUTION
SUITABLE FOR MOUNTING ON
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
APSTA APSTA
1
2
3
4
2
3
......
1
2
3
Power Supply
Network
4
Telephone Module Wiring
AP
STA
AP
STA
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings, pictures, graphs are the properes of
Hangzhou Hikvision Digital Technology Co., Ltd. or its subsidiaries (hereinaer referred to be
“Hikvision”). This user manual (hereinaer referred to be “the Manual”) cannot be reproduced,
changed, translated, or distributed, parally or wholly, by any means, without the prior wrien
permission of Hikvision. Unless otherwise spulated, Hikvision does not make any warranes,
guarantees or representaons, express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to the Axiom Security Control Panel Kit.
The Manual includes instrucons for using and managing the product. Pictures, charts, images and all
other informaon hereinaer are for descripon and explanaon only. The informaon contained in the
Manual is subject to change, without noce, due to firmware updates or other reasons. Please find the
latest version in the company website (hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement and other Hikvision’s trademarks and logos are the
properes of Hikvision in various jurisdicons. Other trademarks and logos menoned below are the
properes of their respecve owners.
This product and - if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the RE
Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the LVD Direcve 2014/35/EU, the
RoHS Direcve 2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of
as unsorted municipal waste in the European Union. See the product documentaon for
specific baery informaon. The baery is marked with this symbol, which may include
leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the baery to your supplier or to a designated collecon point. For more informaon
see:www.recyclethis.info
Product Informaon
6. Connect the baery to the control panel.
Note: The condion of no SIM card, no baery, AC power off, or network disconnected, will cause Control Panel Fault.
7. Fix the power cables with the cable clip.
8. Close the control panel, and ghten the top screws to complete the installaon.
Alarm Input/Alarm Output/RS-485 Wiring
21
Alarm Input Wiring
22
a.
Alarm Output Wiring
23
RS-485 Wiring: Wireless Receiver, keypad, etc.
NC Detector
b.
c.
NO Detector
Unoccupied Zone
The AP mode is only Supported by device with Wi-Fi funcon.
Hybrid Security Control Panel
1. Click System-Network Camera, and you can add cameras for the control panel.
2. Enter the “Device Management” page, select a zone, and select a camera to link with the
zone.
You can also link a camera with the zone via APP, refer to the Security Control Panel User
Manual for details.
The funcon varies depends on the model of device.
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause
harmful interference to radio or television recepon, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operaon
Alarm
Lamp
Alarm
Lamp
Alarm
Lamp
Alarm
Lamp
Siren
Keypad
12VDC
Power Adapter
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
N.C
N.O
2K2
EOL
Z1 G Z2 Z3 G Z4 Z5 G Z6 Z7 G Z8NO/NC1 COM112V_AUX12V_BELL
485+
12V
GG
485
G NO/NC2 COM2 NO/NC3 COM3 NO/NC4 COM4
CON101 L
N
220V~
2
1
Dry Contact
AUX+AUX- D- D+
AUX+
AUX-
OR
D-
D+
C1 PGM1
……
2
2
2
3
1
Telephone Module
Telephone Line Cut Off Indicator
Power Indicator
Telephone
Line
Telephone
Line
Telephone
Telephone
Set up via APP
2a
2
b
2
c 2d
2.2KΩ
NC
C
Z
C
Peripheral Security Detector
2.2KΩ
NO
C
Z
C
Security Control Panel
Security Control Panel
Security Control Panel
Peripheral Security Detector
Z
C
2.2K Ω
2.2K Ω
Z
C
D E T EC TOR
NC
NO
TAMPER
d.
Tamper-proof
Note:
The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9.
The products do not contain the PSTN, 2G, 3G, or 4G funcon, but support the extension module for PSTN, 2G, 3G and 4G.
CAUTION
COPER OR COPER WIRE CANNOT BE
EXPOSED AT THE ELECTRICAL TERMINAL
CAUTION
A TWO-POLE DISCONNECTED
DEVICE (BREAKER) SHALL BE
PROVIDED WHEN INSTALLED
CAUTION
CABLES CAN ONLY BE ROUTED
THROUGH THE REAR PANEL. DO NOT
ROUTE THE ANTENNA WIRE THROUGH
THE ELECTRICAL BOARD
CON101
L
N
220V~
NULL
Line
Causc
Line
GND
4
AP
STA
AP
STA
UD15863B-A
Wireless Detector
Wireless Output expander
Siren
Keyfob
Partition
Zone
Alarm output Alarm output
Scheduled arming/disarming
SMS notification
(with 3G/4G/GPRS module)
Network camera accessing
Application
Protocol
Wired network
Cellular Network
(with 3G/4G/GPRS module)
Standard
Encryption
Configuration
Distance
TAMPER Switch
Network Interface
Telephone Interface
RS-485 Terminal
Siren Power Interface
Battery Interface
User
Tag
Operation Temperature
Operation Humidity
Dimension (W × H × D)
1, 12V
Lithium battery (-P model)
User
Installer: 1
A
dministrator: 1
M
anufactuer:1
O
perator: 45
12
Others
–10 °C to 55 °C (-4 °F to +122 °F)
10% to 90% (No condensing)
P
lastic Case: 220 mm (8.6") × 152 mm (6.0") × 31.5 mm(1.2")
Wi-Fi
802.11b/g/n
6
4/128-bit WEP,WPA/
W
PA2,WPA-PSK/WPA2-
PSK,WPS
AP Mode
Indoor: ≤ 50 m
Outdoor: ≤ 100 m
Interface &
Component
1, front cover tamper-proof
1, RJ45 10M/100M Ethernet Interface
1, PSTN expander interface
1, extended up to 64 inputs/outputs (with RS-485 module),
a
nd 9 wired keypads extendable
Application &
Protocol
i
VMS-4200 (client software)
Hik-Connect (mobile client)
I
SAPI: Supports client software and web client
C
loud P2P: Supports cloud P2P privacy protocol
DC09: ARC accessible (CID/SIA)
Network
10M/100M Ethernet
S
upports report push- notification to ARC & Cloud
Alarm input
8
8
on-board zones, and 56 wired/wireless zones expadable
4 on-board outputs, and 60 wired/wireless outputs expadable
Supported
S
upports up to 8 mobile phone numbers
4
Model DS-PHA64-W4P
Hybrid Security Control Panel with Plastic Case
Device
connection
Up to 56
Up to 8
1
wired siren (on-board connection)
2 wireless sirens
8, valid operation interval: 3 s