Installation Manual

HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A 1 of 6
HID ProxTrak
TM
This de vi ce c ompli es with pa rt 15 of the FCC
may ca us e u nd es ired op era tio n.
inte rfere nc e re ci ev ed, in cl udi ng in terfe ren ce tha t
inte rfere nc e, a nd (2) T his d ev ic e mus t ac c ept an y
con dit ion s: (1) T his d ev ic e may no t c aus e harmful
rules . Ope rati on is s ubj ec t to th e fo ll owin g two
1998 HID CORPORATION
U.S. PATENT NO. 4,7 30 ,18 8 5 ,04 1,6 25
C
FCC ID: JQ6601 5
ELECTRICAL RATING: 1 0.8 -13. 2VDC/25 0mA
REFER TO OPERATORS MANUAL 601 5-90 0.
ACCESS CONTROL SYSTEM UNIT ACCESSORY.
8T29
R
LISTED
HID CORPORATION
11.80 1.00
11.80
.156 X .04 DEEP
12 PLACES
0.00
1.64
2.625
4.00
1.64
2.625
4.00
4
.
0
0
4
.
0
0
Installation Requirements
The following instructions will explain the installation and
operation procedure for the AMR100 Property Pass
Reader. The instructions include these sections:
Installation Instructions
Mounting Preparation
Cabling Preparation
Mounting
O-Ring
Switch Settings
Jumper Settings
Power Supply
Cover Installation
AMR100 Property Pass Reader
AMR100 Property Pass Reader Installation Manual (6015-900)
Installation Instructions
Mounting Preparation
1. Determine an appropriate mounting position for the
AMR100 Reader.
2. Install an electrical box or drill mounting holes for #6
fasteners. Starter holes for mounting are indicated on
Figure 2.
3. The Reader should be mounted at least 6" away from
any metallic surface 12"x12" or larger. Incidental metal
such as aluminum studs and conduit can be compen-
sated.
Figure 1
Important Product Specifications
Environmental Characteristics
Operating Temperature Range -0
o
C to 70
o
C (32
o
F to 150
o
F)
Storage Temperature Range -40
o
C to 85
o
C (-40
o
F to 185
o
F)
Power Requirements
Operating Voltage Range 12.0VDC ± 1.2VDC
Peak Current 12VDC 1.5A
Average Current 1.0A
Excitation Frequency 125KHz ± 1 KHz
Parts List (Included) Quantity
1) AMR100 Property Pass Reader 1
2) O-ring - 12"diameter x .25" thick 1
3) #6-32x.625 Flathead Screw 1
4) Installation Manual 1
5) Front Cover Label 1
6) Strain Relief Nut 2
Parts List (NOT Included)
1) External 12V power supply 1
2) #6 Mounting Screws A/R
3) Cable (See requirements below) A/R
Cabling Requirements
Shielded
Power & Ground - 18AWG- 22AWG
All other signals - 24 AWG minimum
Strain Relief Nut cable range: .19 to .390
Place screw to
secure top cover
here.