REV DESCRIPTION DATE M REVISED PER ECO #E5355A-30 APPROVED NOTE: Cover sheet is for Revision Control only, and is not to be sent with document. REV SHEET 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 REV STATUS M M M M M M M M M M M M OF SHEETS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 REV SHEET TOLERANCES APPROVALS DATE HID CORPORATION .XX = +/- .03” DWN J.
Installation Manual – 5355A-900 Rev M ProxPro Reader - Wiegand/Clock and Data 5355/8A ____________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page, E-mail -www.hidcorp.
ProxPro Reader™ Wiegand/Clock-Data Installation Manual System Overview The ProxPro reader is a self contained proximity reader. The two piece polycarbonate enclosure has an rubber Gasket that seals the pieces together and a cable fitting that seals the cable entry. The water resistant unit is approved for outdoor use. The enclosure is designed to fit on a single gang electrical box. A Bi-color LED and audible tone enhance user feedback.
descriptions are on the PCB guard in the reader. Connect the drain line of the shield to terminal 2 (Power Supply Ground). Terminal 5, Data Return, is to be connected to the ground of the Host if the power supply ground is not common with the Host. The opposite end of the drain line should be cut flush with the jacket and left disconnected. 6. If the tamper feature is available on the Host, connect the tamper switch using the connections recommended by the Host documentation.
Cable Notes: 1) When using 5 conductor cable, the power supply and Host must have a common ground (voltage reference). 2) 6 conductor cable is required when controlling the red and green LED. (Alpha 1296 C or equivalent) 3) 7 conductor cable is required when both green and red LED’s are controlled by the Host and the power supply and Host "ground" are separate. (Alpha 1297 C or equivalent) 4) A 22 AWG twisted pair, shielded, stranded cable is often required for the tamper switch.
P1 TB1 O O O O O O O O O O O 123 1 - DC + 2 - GND 3 - DATA "0" 4 - DATA "1" 5 - DATA RTN 6 - Green LED 7 - Red LED 8 - Beeper 9 - Hold 10 - COM 11 - Tamper TAMPER SW 1 - n/o 5.00" (127mm) 3.28" (83.3mm) SW1 3 - n/c P2 5.00" (127mm) mounting holes (2 places) 1.00" (25.
Switch 1-1 Hardware Identity When set in the "on" position the unit is configured for "Wiegand" interface. The "off" position configures the unit for "Clock and data" interface. Switch 1-2 Audible Tone Control The Audible Tone (Beeper) may be enabled or disabled to sound when an access card is read. When enabled, the audible tone is sounded when the a card is successfully read. When the Beeper is disabled, the only method to activate the Beeper is to use the external Beeper control line.
processing required of the host system. The user interface has been implemented in the most generic fashion to give the integrator the most flexibility. The Second configuration (S version, direct connect keypad), the host must scan the keypad directly using a separate cable. K Version - Internal keypad processing Parity and Length options must be factory configured. Contact customer service to enable these options. Parity Option The default does not included parity in the data message.
The whole message is similar to the "Standard 26 Bit Wiegand" formatted message. The format consists of two parity bits at the opposite ends, one odd and the other even. Each parity bit covering exactly one half of the message. PXXXXXXXX......XXXXXXXXP EXXXXXXXX... ...XXXXXXXXP Keypad Scanning 2 of 7 (K version) This mode requires a separate cable to be supplied that connects to the Keypad board, inside the ProxPro, to the Host via P2. P2 is a 7 position terminal strip.
This table indicates the connection between the connector pins when a key is pressed. For example, if key 3 is pressed P2-5 is connected (shorted) to P2-1. This is available on the Serial ProxPro 5355XXSXX versions. Rows P2-5 3 6 9 # P2-1 P2-2 P2-3 P2-4 Columns P2-6 2 5 8 0 P2-7 1 4 7 * D Version – Bufferd Direct connect keypad Scanning - 3 X 4 Matrix format The ProxPro reader is available with a 3 x 4 matrix keypad.
ProxPro Reader™ Specifications Read Distance - using ProxCard II ! ! ! ! ! ! Over all Operating Limits, minimum (@12VDC)) Non-Metallic Mounting, typical (@12VDC) Mounted on Metal, typical (@12VDC) Overall Operating Limits, minimum (@24VDC) Non-Metallic Mounting, typical (@24VDC) Mounted on Metal, typical (@24VDC) 5.0 inches (12.7 cm) 8.0 inches (20.3 cm) 5.5 inches (14 cm) 5.5 inches (14 cm) 9.0 inches (23 cm) 6.0 inches (15.
Product Configuration/Ordering Options 5355 A G N 00 -XXXX Y Customer Custom Artwork or Firmware Number 1 through 9, A through Z Customer Custom Number Configuration Options - (00 standard) Standard Hardware Options - N = None, K = Standard Keypad (internal or 2 of 7), S = Direct Connect Keypad (3 x 4 type), D = Buffered Direct Connect Keypad (3 x 4 type) Color - G = Gray, B = Beige Model Number Suffix Model Number 5355 = ProxPro Wiegand Model Number 5358 = ProxPro Clock/Data Final Assembly Number = 5355-30