ITEM #0599849, 0599656, 0599848 CROSSWINDS II CEILING FAN MODEL #40821, 40823, 40822 Español p. 23 ATTACH YOUR RECEIPT HERE Serial Number _________________________ Purchase Date _________________________ Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-643-0067, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
TABLE OF CONTENTS Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Hardware Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Preparation . . . . . . . . . . . . . . . . .
PACKAGE CONTENTS E D A C N S H F B J K M L O T I G U PART Q P V W X DESCRIPTION R Y QUANTITY A Downrod 1 B Downrod Pin (preassembled to Downrod [A]) 1 C Downrod Clip (preassembled to Downrod [A]) 1 D Canopy 1 E Mounting Bracket (preassembled to the Canopy [D]) 1 F Canopy Cover (preassembled to Canopy [D]) 1 G Motor Assembly 1 H Switch Housing (preassembled to Motor Assembly [G]) 1 I Switch Housing Cap (preassembled to Light Kit [J]) 1 J Light Kit 1 K F
HARDWARE CONTENTS (shown actual size) AA BB Plug Button Qty. 1 Wire Connector Qty.
SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. • Before you begin installing the fan, disconnect the power by removing fuses or turning off the circuit breakers. • Make sure all electrical connections comply with local codes, ordinances, the National Electrical Code, and ANSI/NFPA 70-199. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring.
SAFETY INFORMATION CAUTION: Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams. CAUTION: Be sure the outlet box is properly grounded or that a ground (green or bare) wire is present. CAUTION: Carefully check all screws, bolts and nuts on the fan motor assembly to ensure they are secured. CAUTION: This device complies with Part 15 of the FCC Rules.
INITIAL INSTALLATION 1. Turn off the circuit breakers and the wall switch to the fan supply line leads. 1 DANGER: Failure to disconnect the power supply prior to installation may result in serious injury or death. 2. Determine the mounting method to use. Helpful Hint: Standard mounting is best suited for ceilings 8 ft. or higher. For taller ceilings you may want to use a longer downrod (sold separately). Angle mounting is best suited for angled or vaulted ceilings.
INITIAL INSTALLATION 4. Loosen all four mounting brackets screws (W), then completely remove the two mounting bracket screws (W) from the round holes of canopy (D). Set aside for later use. 4 E Detach mounting bracket (E) from canopy (D). Note Do NOT remove the mounting bracket screws (W) from the slotted holes. W D 5.
STANDARD OR ANGLE MOUNTING INSTRUCTIONS 1. Partially loosen the two set screws (X) in the yoke at the top of the motor assembly (G) to allow for installation of the downrod (A). 1 G X Yoke 2. Remove the downrod pin (B) and downrod clip (C) from the downrod (A). Insert downrod (A) -- or a longer downrod, if purchased -- through canopy (D), then feed the wire harness from the fan through the downrod (A). Secure downrod (A) into the yoke of motor assembly (G). 2 A C B D A G 3.
STANDARD OR ANGLE MOUNTING INSTRUCTIONS 4. Install the ball end of the downrod (A) into the opening of the mounting bracket (E). Rotate the fan in the mounting bracket (E) until a slot in the ball end of the downrod (A) engages the tab in the mounting bracket (E). 4 E DANGER: The fan and/or downrod (A) should not rotate in the mounting bracket (E) if installed correctly. Failure to align the slot with the tab may result in fan falling causing serious injury or death. A Slot A E Tab 5.
CLOSEMOUNT INSTRUCTIONS 1. Remove and discard the canopy cover (F) from the bottom of the canopy (D). 1 Note: The downrod (A) and canopy cover (F) are not used in this type of installation. D F 2. Remove the three Phillips-head closemount screws (Y) from the top of the motor assembly (G). Align the canopy (D) with the holes in the top of motor assembly (G), then re-install the Phillips-head closemount screws (Y) to secure the canopy (D) to the top of the motor assembly (G). 2 Y D G 3.
WIRING CAUTION: Fan must be installed with included receiver. Antenna 2. Connect the Green wires from the downrod (A) and the mounting bracket (E) to the Bare/Green (ground) supply wire using a wire connector (BB). Note: Closemount installation does not use a downrod (A), so there will only be two Green wires to connect.
FINAL INSTALLATION Note Closemount installation will not have the downrod (A) or canopy cover (F). Downrod (A) is shown/referenced, but instructions are applicable to both standard and closemount-style installations. 1. Read and discard the paper tag attached to the wire E 1 hooks of the mounting bracket (E). Wrap the wire harness coming from the downrod (A) around the wire hooks.
FINAL INSTALLATION 3. Align the canopy (D) over the loose mounting bracket screws (W) preassembled on mounting bracket (E). Place the keyholes of the canopy (D) onto the mounting bracket screws (W) and rotate the canopy (D) counterclockwise. Note: While raising the canopy (D), avoid pinching wiring or antenna of the receiver of remote pack (P) between the mounting bracket (E) and the canopy (D). 4. Secure the canopy (D) with the mounting bracket screws (W) previously removed (Step 4, page 8).
FINAL INSTALLATION Note If you wish to install the fan without the light kit, proceed to step 11. 6 6. To install the light kit (J), first remove all three switch housing screws (V) from the switch housing cap (I). Then connect the single-pin connectors from the switch housing (H) to the single-pin connectors from the light kit (J) -- blue to black and white to white. H Single-pin Connector I V J 7. Align the notch in the switch housing cap (I) with the reverse switch on the switch housing (H).
FINAL INSTALLATION 9. Remove the preassembled finial (L), finial cap (K), hex nut (T) and rubber washer (S) from the light kit (J). 9 J S T K L 10. Lift the glass bowl (M) onto the threaded rod at the bottom of the light kit (J). Re-install rubber washer (S) and secure with hex nut (T). Lift the finial cap (K) onto the threaded rod, securing with finial (L). 10 Proceed to step 13. M S T K L 11.
FINAL INSTALLATION 12. Remove all three switch housing screws (V) from the switch housing cap (I). Align the notch in the switch housing cap (I) with the reverse switch located on switch housing (H), then re-install all three switch housing screws (V). 12 H V 13. OPTIONAL: If you wish to install the wall bracket from remote pack (P), choose desired location and insert screws from remote pack (P) into holes of wall bracket and into installation site.
OPERATING INSTRUCTIONS 1. Remove the battery cover from the back of the remote found in remote pack (P). Insert the battery from remote pack (P) into the remote; ensure polarity of battery matches the polarity indicated in the battery compartment -- positive (+) to positive (+) and negative (-) to negative (-). Replace the battery cover and press the fan power button on the remote to ensure the LED indicator illuminates and the remote turns on the fan.
CARE AND MAINTENANCE At least twice each year, tighten all screws on the fan. Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching the finish. Clean the blades with a lint-free cloth. You may occasionally apply a light coat of furniture polish to wood blades for added protection. Bulb Replacement: Use 40-watt max. candelabra-base bulbs or CFL equivalent. Battery Replacement for Remote: Use A23 12-volt battery.
TROUBLESHOOTING PROBLEM POSSIBLE CAUSE 1. The blades are loose. 2. There is a cracked blade. 3. The outlet box is not secure. The fan is noisy. 4. The mounting bracket is not secure. CORRECTIVE ACTION 1. Check and tighten all screws that hold the fan blades to the blade arms and the motor. 2. Replace the cracked blade. 3. Ensure the outlet box is secured to the building structure. 4. Ensure the mounting bracket is secured to the outlet box and that the screws are tight. 1.
LIFETIME LIMITED WARRANTY The manufacturer warrants this fan to be free from defects in workmanship and materials present at time of shipment from the factory for a lifetime from the date of purchase by the original purchaser. The retailer also warrants that all other fan parts, excluding any glass or plastic blades, to be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser.
REPLACEMENT PARTS LIST For replacement parts, call the customer service department at 1-800-643-0067, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
WARNING: This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation . Changes or Modifications not expressly approved by the party responsible could void the user’s authority to operate this device.