beckon — BUILT-IN GAS RANGE TOP INSTALLATION MANUAL gs 3 — NOTICE — Before beginning installation, read these instructions thoroughly and carefully, Observe all local and national codes, requirements, and ordinances, DO NOT removal permanently affixed labels, warnings, or plates from the product as this may void the warranty. Installers should leave these instructions with the consumer who should retain them for the local inspector's use and for future reference, PRGRT305005S 185.
td Read all safety instructions before using the product. if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death, [Jo not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS . Do not try to light any appliance. . Do not touch any electrical switch. . Do not use any phone in your building. .
READ AND SAVE THESE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE. Dear Valued Customer, Thank you for your purchase this appliance is intended for normal household use only. It is not approved for outdoor or other non-household uses {including sea or air-going vessels). See the Statement of Limited Warranty. If you have any questions, contact the manufacturer. Do not repair or replace any part of the appliance unless specifically recommended in this manual.
SAFETY INFORMATION 1.1 Before you begin. 1.2 Room ventilation. 21 Toolsyouwill need... 8 22 Tools you may need tees es 9 2.3 Materials you may need... 8 PREPARING FOR INSTALLATION CLEARANCES & DIMENSIONS 3.1 Range top Dimensions 3.2 Cutout Dimensions. 3.3 Minimum Clearance Dimensions... curs 11 INSTALLING THE RANGE TOP 41 Install Gas orient ores rise 4.2 Slide Range top Into Cutout...
We have provided many important safety messages in this manual and on the appliance. ALWAYS read and obey all safety messages. This is the safety alert symbol. A This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word “DANGER” “WARNING”, or “CAUTION”. These words mean; INDICATES A HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.
1.1 BEFORE YOU BEGIN Before beginning the installation, switch power off at the service panel and lock the service, disco nesting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. important notes to the installer: Read manual before installing the appliance. Be sure to leave these instructions with the consumer.
§” beyond the front of the cabinets. An air curtain or other overhead range hood, which operates by blowing a downward airflow onto this appliance, shall not be used in conjunction with this gas appliance. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard. To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, determinate or sustain other damage.
30200-44400 109 44400-52900 124 52900-58000 140 58000-64800 1585 64800-81900 164 If the doors or windows that open directly to the outer environment do not have openings corresponding to the ventilation opening specified according to the iota gas power of the product, there must definitely be a fixed ventilation opening in the room.
2.1 TOOLS YOU WILL NEED Phillips screwdriver Flat-blade screwdriver Open-end or adjustable wrench Pipe wrenches {one for backup) Pencil and ruler Safety glasses 18" Drill Bit& Electric ar Hand Drift Saber saw Safety gloves 2.2 TOOLS YOU MAY NEED Joint sealant Pipe fittings Shut off valve Flexible connector TT) ES 2.
Provide adequate clearances between the range top and adjacent combustible surfaces. These dimensions must be met for safe use of your range top. Allow 30" (762 ram) minimum clearance between burners and bottom of unprotected wood or metal cabinet. Installation of a listed microwave oven or cooking appliance over the range top shall conform to the installation instructions packed with that appliance. Built-in oven installation. shall conform to the installation instruction packed with the built-in oven. 3.
Non-combustible (762 mm) | (457 mm) | (127 mm) | (330 Material only to 36” (©14 mm} to bottom of Ventilation hood *Note: 36" without ventilation hood FETE RR TE TEE hhh nt The range top must not be below the counter top. If the appliance is below the counter top, there is a risk of the furniture catching fire which may result in causing property damage, personal injury or death.
4.1 INSTALL GAS REGULATOR 4.2 SLIDE PREARRANGEMENT CUT-OUT Gas regulator is supplied with the range top. Slide the range top centered into the To prevent gas leaks, apply pipe cutout opening. Be sure the front joint compound or tape with Teflon* edge of the counter top is parallel to around ali range top gas inlet male the range top.
The gas connection is located at the rear right bottom of the range top. Shut off main gas supply valve before disconnecting the old range top and keep if off until the new hook-up has been completed. If not already present, install gas shut off valve in an easily accessible location. Make sure all users know where and how to shut off the gas supply to the range top.
| GAS CONNECTION La WE NPT male pigs thread |B Regulator provided wih A —mi wri + Cutie 38 NPT mermaid pio teed + Inlet 12° NPT female ripe thread Adapter Fade correction Adapter ¥ Manual shut-off naive iB Gas pipe 12” 01 34° mmo prevent gas oaks, apy pps fo compound wap pipe farad laps wih Teflon” around ail sie * {extant pipe threads. ; “Teflon: Registered trademark of DuPont Flexible Connector Method 1. Manual shut-off valve (F) shall be installed in.
Never check for leaks with a flame. Do not continue to the next step until all leaks are eliminated. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kappa.
Note: Electrical installation should comply with national and local codes. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, PAN 70 or the Canadian Electric Case, CSA Note: This appliance must be ne Avoid fire hazard or electrical shock. Do not use an adapter plug. Do not use an extension cord. Do not remove grounding prong from electrical power cord.
Electrical Code {CSA} and all focal daces and ordinances. Refer to the illustration below. Grounding plug Grounding type Electrical Outlet Risk of electric shock, short circuit or fire by damage of the main power supply! The main power supply lead must not be clamped, bent or trapped or come into contact with hot parts of the appliance. If the main power supply is damaged, it must be replaced by a qualified electrician, A suitable wall receptacle shall be provided in the vicinity of the product.
1.Place caps on the proper sized burners. lel 2] |@¢C 2.Make sure that the caps are placed ..In the comet positions. 3.Place the grates on the range top. For maximum stability, these grates should only be used in their proper position. Because of the varied bummer sizes, the side grates cannot be exchanged nor can any of the grates be rotated front to back.
1.Turn on power at the breaker Make sure all gas and electrical connections are done safely before checking for ignition of surface boomers. Turn on power at the breaker. 2. Verify the cap and grates placement Make sure all burners are in their correct locations and fully assembled before attempting to operate any burner 3.Ignite the burners Gas burners are controlled with the range top knobs. “HI” symbol indicates the highest cooking power and “LO” symbol corresponds to the lowest cooking power.
4.Test flame: High Setting. Tum the burner to "HI". See appropriate flame characteristics section. If any of the burners continue to burn mostly or completely yellow, call Service. 5.Test Flame: Low Setting. Turn the burner to "LO". Verify that the flame completely surrounds the burner. There should be flame at each burner port and there should be no air gap between the flame and the burner. if any of the burners do not comply, call Service.
This range top leaves the factory set for use with natural gas. When converting to LP gas, the conversion must be performed by a qualified LP gas installer. The conversion instructions and LP orifices are supplied with your range top. Keep these instructions and the orifices in case you want to convert back to natural gas.