HR4136-B1 Reference Manual FOR TIRIS PROXIMITY TAG CID/Data Read/Write Controller With SECS I/II Protocol VERSION: 1.04 HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 Compilation:2022/03/30 Introduction: Thank you for purchasing the HR4136-B1 CIDRW System. Please observe the following points when operating the HR4136-B1: • Please read and understand the content of this manual before using the system. • After reading this manual, store it in a handy location for easy reference whenever necessary. Precautions in using the product READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products.
HR4136-B1 amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products.
HR4136-B1 Consult the dealer or an experienced radio/TV technician for assistance. FCC ID : 2AB67-HR4136-B1 Compliance with : FCC Code of Fedral Requlations,Part 15 Subpart C, Section §15.205 FCC Code of Fedral Requlations,Part 15 Subpart C, Section §15.209 WARNING Changes or modifications not expressly approved by the party responsible for compliance may void the user's authority to operate the equipment.
HR4136-B1 Installation: CIDRW Controller Mount the CIDRW Controller with the two M3 - M4 screws. Note: Tighten the M3 - M4 screws with a torque not exceeding 1.2 Nm. Do not apply organic solvents used with screw locking agents at the locations where the screws are inserted. HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 Antenna Stick antenna 12.4 Rectangular antenna 32mm 22mm 15mm Note:Mount with the two M3 - M4 plastic screws . Champ Core Installation Instructions HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 Wiring Diagram: ANT RS232 Pin No. RS232 4 Ground 5 TXD 6 RXD RS485 Pin No. RS485 4 R+ / D+ 5 R- / D- Antenna cable length : 2M with RP-TNC connecter HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 Systems Architecture: DC 10~24V FUNCTION ST - + HR4135 Gate Controller TX RX 0 1 2 3 4 10/100M Ethernet ANT ADDRESS 0 ON RS232 RS485 RS232 RS485 ANT RS232 RS485 Total 1000m Max. HR4136-B CID R/W Controller Max. 25 set. ANT RS232 RS485 ANT RS232 RS485 ANT RS232 RS485 ANT RS232 RS485 HR4136-B CID R/W Controller Max. 25 set. 1. Each HR4135 gate controller has two RS485 communication ports.
MODEL HRP485 RS485 REPEATER MODEL HRP485 RS485 REPEATER HR4136-B1 1. Use HRP485 Repeater can be connected up to 99 set HR4136-B1 CIDRW Controller. 2. RS485 the maximum connection distance: from HRP485 Repeater to last one HR4136-B1 CIDRW Controller total 1000 m. HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 Transmission Area (information only): Stick antenna Tag : TEXAS INSTRUMENTS 32mm Glass Transponder part number RI-TRP-DR2B The transmission area diagram going through the center of the antenna and indicated on a flat surface vertical to the antenna surface is as indicated below. Y Legend : Normal area Recommended area Unrecommended area X 9 8 7 6 5 4 3 2 HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 Rectangular antenna Tag : TEXAS INSTRUMENTS 32mm Glass Transponder part number RI-TRP-DR2B The transmission area diagram going through the center of the antenna and indicated on a flat surface vertical to the antenna surface is as indicated below. HEART TECH ENTERPRISE CO., LTD.
HR4136-B1 General specifications: Characteristic Specification Comment Supply Voltage Range DC 10 ~ 24V (+/-10%) Supplied from the power terminals Current consumption @12VDC Average 60mA ; Peak 160mA Approx. 2A max, with rush current Transmitting Radio Frequency Typical 134.
HR4136-B1 DIP Switch settings specifications: SW No. Name 1~2 Baud rate 3 Beeper status 4 Test mode Description SW 1 2 ON OFF ON OFF 4800 9600 19200 28800 OFF ON OFF ON OFF OFF ON ON The beeper is enabled when a correct Stream Function executed. The beeper is disabled. The controller automatic read tag RFID repeatedly. Normal operation. HEART TECH ENTERPRISE CO., LTD.