TEST REPORT For Dongguan LongRich Electronic Co., Ltd. Power Strip with 3 USB Ports Model No.: GL202006, GL-US006, GL202006A Test Report Number: CQASZ20210400194S Shenzhen Huaxia Testing Technology Co., Ltd. Address: 1F.
Page 1 of 63 Report No.: CQASZ20210400194S TEST REPORT IEC 62368-1 Audio/video, information and communication technology equipment Part 1: Safety requirements Report Number .............................. : CQASZ20210400194S Date of issue ................................... : Apr. 09, 2021 Total number of pages .................... : 63 pages Applicant’s name .......................... : Dongguan LongRich Electronic Co., Ltd Address ...........................................
Page 2 of 63 Report No.: CQASZ20210400194S Testing procedure and testing location: Testing Laboratory ........................... : Shenzhen Huaxia Testing Technology Co., Ltd. Testing location/ address ................. : 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China. Prepare by (name + signature) ...... : Robert Zhao Reviewed by (name + signature) ... : Hardy Ding Approved by (name + signature) ...
Page 3 of 63 Report No.: CQASZ20210400194S Test item particulars................................................... : Classification of use by................................................. : Ordinary person Instructed person Skilled person Children likely to be present Supply Connection ....................................................... : AC Mains DC Mains External Circuit - not Mains connected ES1 ES2 ES3 Supply % Tolerance ....................................................
Page 4 of 63 Report No.: CQASZ20210400194S Possible test case verdicts .................................... : - test case does not apply to the test object ............. : N/A - test object does meet the requirement ................... : P (Pass) - test object does not meet the requirement ............. : F (Fail) Testing...................................................................... : Date of receipt of test item ........................................ : Apr.
Page 5 of 63 Report No.: CQASZ20210400194S Energy Source Identification And Classification Table: (Note 1: Identify the following six (6) energy source forms based on the origin of the energy.) (Note 2: The identified classification e.g., ES2, TS1, should be with respect to its ability to cause pain or injury on the body or its ability to ignite a combustible material. Any energy source can be declared Class 3 as a worse case classification e.g. PS3, ES3.
Page 6 of 63 Report No.: CQASZ20210400194S Thermal burn injury (Clause 9) (Note: Identify the surface or support, and corresponding energy source classification based on type of part, location, operating temperature and contact time in Table 38.
Page 7 of 63 Report No.: CQASZ20210400194S Energy source diagram Indicate which energy sources are included in the energy source diagram.
Page 8 of 63 Report No.: CQASZ20210400194S Overview of employed safeguards Clause Possible Hazard 5.1 Electrically-caused injury Body Part (e.g.
Page 9 of 63 -- -- 8.1 Mechanically-caused injury Body Part (e.g. Ordinary) Energy Source (MS3: High Pressure Lamp) Ordinary Report No.: CQASZ20210400194S -- -- -- Safeguards Basic Supplementary Reinforced (Enclosure) MS1: Sharp edges and corners N/A N/A N/A Ordinary MS1: Equipment mass (<7kg) N/A N/A N/A 9.1 Thermal Burn Body Part (e.g., Ordinary) Energy Source (TS2) Ordinary TS1: External surfaces 10.1 Radiation Body Part (e.g.
Page 10 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 4 GENERAL REQUIREMENTS P 4.1.1 Acceptance of materials, components and subassemblies P 4.1.2 Use of components P 4.1.3 Equipment design and construction P 4.1.15 Markings and instructions .................................. : 4.4.4 Safeguard robustness 4.4.4.2 Steady force tests .............................................. : (See Annex T.5) P 4.4.4.3 Drop tests .......................
Page 11 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict 5.2.2.2 Steady-state voltage and current ......................... : See appended table 5.2) P 5.2.2.3 Capacitance limits ................................................ : (See appended table 5.2) N/A 5.2.2.4 Single pulse limits................................................. : (See appended table 5.2) N/A 5.2.2.5 Limits for repetitive pulses ...................................
Page 12 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark a) a.c. mains transient voltage ............................ : 2500Vpeak Verdict b) d.c. mains transient voltage ........................... : c) external circuit transient voltage ...................... : d) transient voltage determined by measurement .............................................................................. : 5.4.2.
Page 13 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Temperature (°C) ............................................... : 30 Duration (h) ...................................................... : 48 5.4.9 Electric strength test .......................................... : (See appended table 5.4.9) P 5.4.9.1 Test procedure for a solid insulation type test 5.4.9.2 Test procedure for routine tests N/A 5.4.
Page 14 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 5.5.8 Insulation between the mains and external circuit consisting of a coaxial cable .............................. : (See Annex G.10.3) 5.6 Protective conductor P 5.6.2 Requirement for protective conductors P 5.6.2.1 General requirements P 5.6.2.2 Colour of insulation P 5.6.3 Requirement for protective earthing conductors 2 Protective earthing conductor size (mm ) ...........
Page 15 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Instructional Safeguard........................................: (See F.4 and F.5) N/A 5.7.6 Prospective touch voltage and touch current due to external circuits N/A 5.7.6.1 Touch current from coaxial cables N/A 5.7.6.2 Prospective touch voltage and touch current from external circuits N/A 5.7.
Page 16 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Special conditions if conductors on printed boards are opened or peeled 6.4.3.3 Single Fault Conditions ........................................ : Verdict N/A (See appended table 6.4.3) N/A Special conditions for temperature limited by fuse N/A 6.4.4 Control of fire spread in PS1 circuits N/A 6.4.5 Control of fire spread in PS2 circuits P 6.4.5.2 Supplementary safeguards .....................
Page 17 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 6.6 Safeguards against fire due to connection to additional equipment Output terminal complies with Clause Q.1 according to manufacturer’s choice External port limited to PS2 or complies with Clause Q.1 Verdict P P 7 INJURY CAUSED BY HAZARDOUS SUBSTANCES N/A 7.2 Reduction of exposure to hazardous substances N/A 7.3 Ozone exposure N/A 7.4 Use of personal safeguards (PPE) N/A 7.
Page 18 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict 8.5.5 High Pressure Lamps N/A 8.5.5.1 Energy Source Classification N/A 8.5.5.2 High Pressure Lamp Explosion Test .....................: (See appended table 8.5.5.2) N/A 8.6 Stability Equipment mass < 7.0kg and is classified as MS1 N/A 8.6.1 Product classification N/A Instructional Safeguard ..........................................: 8.6.2 Static stability N/A 8.6.2.
Page 19 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 8.11 Mounting means for rack mounted equipment N/A 8.11.1 General N/A 8.11.2 Product Classification N/A 8.11.3 Mechanical strength test, variable N ...................: N/A 8.11.4 Mechanical strength test 250N, including end stops N/A 8.12 Telescoping or rod antennas ................................. (See Annex T) Verdict N/A Button/Ball diameter (mm) ...................................
Page 20 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test 10.4.1.h) Enclosure containment of optical radiation.......... : N/A 10.4.1.i) Exempt Group under normal operating conditions ............................................................ : N/A 10.4.2 Instructional safeguard ........................................ : N/A 10.5 Protection against x-radiation N/A 10.5.1 X- radiation energy source that exists equipment : (See appended table B.3 & B.
Page 21 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict B NORMAL OPERATING CONDITION TESTS, ABNORMAL OPERATING CONDITION TESTS AND SINGLE FAULT CONDITION TESTS P B.2 Normal Operating Conditions P B.2.1 General requirements......................................... : (See Test Item Particulars and appended test tables) Audio Amplifiers and equipment with audio amplifiers ............................................................
Page 22 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict B.4.7 Continuous operation of components No such components B.4.8 Class 1 and Class 2 energy sources within limits during and after single fault conditions During and after a single fault condition, a class 1 or class 2 energy sources did not become a class 3 energy source.
Page 23 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark F.2.1 Letter symbols according to IEC60027-1 P F.2.2 Graphic symbols IEC, ISO or manufacturer specific P F.3 Equipment markings P F.3.1 Equipment marking locations F.3.2 Equipment identification markings F.3.2.1 Manufacturer identification ................................ : See marking plate F.3.2.2 Model identification ............................................
Page 24 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark F.3.7 Equipment IP rating marking ............................. : IPX0 F.3.8 External power supply output marking P F.3.9 Durability, legibility and permanence of marking P F.3.10 Test for permanence of markings F.4 Instructions After test, there was no damage on the label, the marking on the label did not fade. There was no curling and lifting of the label edge.
Page 25 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark G.3.1 Thermal cut-offs No thermal cut-offs G.3.1.1a) &b) Thermal cut-outs separately approved according to IEC 60730 with conditions indicated in a) & b) N/A G.3.1.1c) Thermal cut-outs tested as part of the equipment as indicated in c) N/A G.3.1.2 Thermal cut-off connections maintained and secure N/A G.3.2 Thermal links N/A G.3.2.1a) Thermal links separately tested with IEC 60691 G.3.2.
Page 26 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark G.5.3.1 Requirements applied (IEC61204-7, IEC615581/-2, and/or IEC62368-1) .................................... : The isolation transformer meets the requirements given in G.5.3.2 and G.5.3.3 P Position ................................................................ : Power Transformer T1 Method of protection .......................................... : Electronic protection G.5.3.
Page 27 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test G.5.4.9 Series motors Result - Remark Verdict N/A Operating voltage .............................................. : G.6 Wire Insulation P G.6.1 General G.6.2 Solvent-based enamel wiring insulation G.7 Mains supply cords G.7.1 General requirements Approved mains supply cords used P Type .....................................................................: (See appended table 4.1.
Page 28 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict G.8.3.3 Temporary overvoltage ........................................ : (See appended table B.3) G.9 Integrated Circuit (IC) Current Limiters G.9.1 a) Manufacturer defines limit at max. 5A. G.9.1 b) Limiters do not have manual operator or reset G.9.1 c) Supply source does not exceed 250 VA ............ : G.9.1 d) IC limiter output current (max. 5A) ...................... : G.9.
Page 29 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Compliance with cemented joint requirements (Specify construction) .......................................... : G.13.5 Verdict Insulation between conductors on different surfaces N/A Distance through insulation ..................................: (See appended table 5.4.4.5) N/A Number of insulation layers (pcs) ...................... : G.13.6 Tests on coated printed boards N/A G.13.6.
Page 30 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark H CRITERIA FOR TELEPHONE RINGING SIGNALS N/A H.1 General N/A H.2 Method A N/A H.3 Method B N/A H.3.1 Ringing signal N/A H.3.1.1 Frequency (Hz) .................................................. : H.3.1.2 Voltage (V) ......................................................... : H.3.1.3 Cadence; time (s) and voltage (V) ..................... : H.3.1.4 Single fault current (mA):..
Page 31 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test L DISCONNECT DEVICES L.1 General requirements L.2 Permanently connected equipment N/A L.3 Parts that remain energized N/A L.4 Single phase equipment L.5 Three-phase equipment N/A L.6 Switches as disconnect devices N/A L.7 Plugs as disconnect devices L.8 Multiple power sources N/A M EQUIPMENT CONTAINING BATTERIES AND THEIR PROTECTION CIRCUITS N/A M.1 General requirements N/A M.
Page 32 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark M.4.4.3 Drop and charge/discharge function tests N/A Drop N/A Charge N/A Discharge N/A M.4.4.4 Charge-discharge cycle test N/A M.4.4.5 Result of charge-discharge cycle test N/A M.5 Risk of burn due to short circuit during carrying N/A M.5.1 Requirement N/A M.5.2 Compliance and Test Method (Test of P.2.3) N/A M.
Page 33 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test N ELECTROCHEMICAL POTENTIALS Metal(s) used ...................................................... : O Result - Remark Verdict N/A Pollution degree considered MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES P Figures O.1 to O.20 of this Annex applied .......... : Considered P SAFEGUARDS AGAINST ENTRY OF FOREIGN OBJECTS AND SPILLAGE OF INTERNAL LIQUIDS N/A P.1 General requirements N/A P.2.
Page 34 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Q.1.1 b) Impedance limited output P - Regulating network limited output under normal operating and simulated single fault condition P Q.1.1 c) Overcurrent protective device limited output N/A Q.1.1 d) IC current limiter complying with G.9 N/A Q.1.2 Compliance and test method Q.
Page 35 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test S.3 Flammability test for the bottom of a fire enclosure Result - Remark Verdict N/A Samples, material ............................................... : Wall thickness (mm) ............................................ : Cheesecloth did not ignite N/A S.4 Flammability classification of materials N/A S.
Page 36 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Torque value (Nm) .............................................: U MECHANICAL STRENGTH OF CATHODE RAY TUBES (CRT) AND PROTECTION AGAINST THE EFECTS OF IMPLOSION N/A U.1 General requirements N/A U.2 Compliance and test method for non-intrinsically protected CRTs U.3 Protective Screen...................................................
Page 37 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 4.1.2 TABLE: List of critical components Verdict Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of conformity1 Enclosure SABIC INNOVATIVE PLASTICS US LLC 940(f1) V-0, 120ºC UL 94 UL 121562 Plug YING HAO SY-19 125V 10A UL 817 ETL Power cord CHING CHENG SVT 3*0.
Page 38 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test - Copper Wire - Tiw wire - Mylar tape Result - Remark SHANTOUSHENG ∮0.15 ANG ∮0.27 ELECTRICAL INDSTRAL CO.,LTD 155ºC NZHEN DRUN SCIENCE AND TECHNOLOGY CO ∮0.70 130ºC TIW-B JINGJIANG(YA HUA)CO.,LTD 4.7mm UL 1446 Verdict UL E 239508 UL 2353 UL E 335481 130ºC ANSI/UL 1446 22.0mm UL E 165111 10.0mm 13.0mm - Teflon tube - Varnish Y1 capacitor (CY1) FLUOTECH INDUSTRIES CO.
Page 39 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test 4.8.4, 4.8.5 Result - Remark TABLE: Lithium coin/button cell batteries mechanical tests Verdict N/A (The following mechanical tests are conducted in the sequence noted.) 4.8.4.2 TABLE: Stress Relief test Part Material Oven Temperature (°C) Comments -- -- -- -- 4.8.4.3 TABLE: Battery replacement test Battery part no. ..............................................................
Page 40 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 4.8.5 TABLE: Lithium coin/button cell batteries mechanical test result Verdict N/A Test position Surface tested Force (N) Duration force applied (s) -- -- -- -- -- -- -- -- Supplementary information: 5.2 P Table: Classification of electrical energy sources 5.2.2.2 – Steady State Voltage and Current conditions No. Supply Voltage (V/Hz) 1 264/60 2 3 264/60 264/60 Location (e.g.
Page 41 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Voltage circuit designation) -- -- -- Result - Remark Verdict Duration (ms) Upk (V) Ipk (mA) Normal -- -- -- Abnormal -- -- -- Single fault – SC/OC -- -- -- -- 5.2.2.5 - Repetitive Pulses No. Supply Voltage Location (e.g.
Page 42 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Enclosure (External, plastic, near transformer T1) 53.4 50.6 77 Ambient 25.0 25.0 -- Supplementary information: Type C output: 5Vdc, 3.1A. #: External surfaces touched occasionally for periodes: 1s
Page 43 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict P 5.4.2.2, TABLE: Minimum Clearances/Creepage distance 5.4.2.4 and 5.4.3 cl (mm) 2 Required3 cr (mm) cr (mm) -- -- -- -- 0.06 1.5 3.6 3.0 3.6 240 0.06 1.5 3.2 3.0 3.2 420 240 0.06 3.0 7.6 5.0 7.6 T1 core to Secondary 500 240 64.10 3.0 6.9 5.0 6.9 T1 Primary to Secondary 500 240 64.10 3.0 7.7 5.0 7.7 Primary to Enclosure 420 240 0.06 3.0 >10 5.
Page 44 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 5.4.2.4 TABLE: Clearances based on electric strength test Test voltage applied between: Verdict N/A Required cl (mm) Test voltage (kV) peak/ r.m.s. / d.c. Breakdown Yes / No -- -- -- -Supplementary information: 5.4.4.2, 5.4.4.5 c) 5.4.4.
Page 45 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark 5.5.2.2 TABLE: Stored discharge on capacitors Verdict N/A Supply Voltage (V), Hz Test Location Operating Condition (N, S) Switch position On or off Measured Voltage (after 2 seconds) ES Classification -- -- -- -- -- -- Supplementary information: X-capacitors installed for testing are: bleeding resistor rating: ICX: Notes: A.
Page 46 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict [3] Specify method used for measurement as described in IEC 60990 sub-clause 4.3 [4] IEC60990, sub-clause 6.2.2.7, Fault 7 not applicable. [5] (*) IEC60990, sub-clause 6.2.2.2 is not applicable if switch or disconnect device (e.g., appliance coupler) provided. 6.2.
Page 47 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test 6.2.3.
Page 48 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test B.2.5 TABLE: Input test Result - Remark Verdict P U (V) I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status 90V/60Hz 0.370 -- 19.25 -- F1 0.370 Normal operation 100V/60Hz 0.336 -- 19.06 -- F1 0.336 Normal operation 240V/60Hz 0.177 -- 18.99 -- F1 0.177 Normal operation 264V/60Hz 0.165 -- 19.12 -- F1 0.165 Normal operation 90V/50Hz 0.363 -- 19.29 -- F1 0.
Page 49 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Ambient temperature (C) ............................................................. : See below Power source for EUT: Manufacturer, model/type, output rating . : See below Component Fault No. Condition Supply voltage, (V) Test time (ms) Fuse no. Fuse current, (A) T-couple Temp. (C) Observation USB output SC 264V 10min F1 0.
Page 50 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark B.4 TABLE: Fault condition tests Verdict P Ambient temperature (C) ............................................................. : See below Power source for EUT: Manufacturer, model/type, output rating . : See below Component Fault No. Condition Supply voltage, (V) Test time (ms) Fuse no. Fuse current, (A) T-couple Temp. (C) Observation T1 Pin 1-2 SC 264V 10mins F1 0.
Page 51 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Annex M TABLE: Batteries Result - Remark Verdict N/A The tests of Annex M are applicable only when appropriate battery data is not available N/A Is it possible to install the battery in a reverse polarity position? ......................... : N/A Non-rechargeable batteries Discharging Meas. current Manuf. Specs. Max. current during normal condition -- -- Max.
Page 52 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Annex Q.1 Requirement + Test Result - Remark Verdict P TABLE: Circuits intended for interconnection with building wiring (LPS) Note: Measured UOC (V) with all load circuits disconnected: Output Circuit Components USB 5V output Normal USB 5V output Single fault: U2 SC Type C 5V output Normal Type C 5V output Single fault: U2 SC Uoc (V) Isc (A) S (VA) Meas. Limit Meas. Limit 4.997 3.49 8 17.44 100 0 0 8 0 100 4.
Page 53 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test Result - Remark Verdict Top enclosure Plastic See table 4.1.2 1300 * Bottom enclosure Plastic See table 4.1.2 1300 * Side enclosure Plastic See table 4.1.2 1300 * Supplementary information: * During and after the tests, the energy source did not become accessible.
Page 54 of 63 Report No.: CQASZ20210400194S IEC 62368-1 Clause Requirement + Test T.7 TABLE: Drop tests Part/Location -- Result - Remark Verdict N/A Material Thickness (mm) Drop Height (mm) Observation -- -- -- * Supplementary information: * During and after the tests, the energy source did not become accessible. T.8 TABLE: Stress relief test Part/Location Material The complete EUT Plastic P Thickness (mm) See table 4.1.
Page 55 of 63 Report No.: CQASZ20210400194S IEC 62368-1 with U.S.A. National differences Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 62368-1 2th Ed. U.S.A. NATIONAL DIFFERENCES Audio/video, information and communication technology equipment – Part 1: Safety requirements Differences according to ................: CSA/UL 62368-1:2014 Attachment Form No. .....................: US&CA_ND_IEC623681B Attachment Originator....................
Page 56 of 63 Report No.: CQASZ20210400194S IEC 62368-1 with U.S.A. National differences Clause Requirement + Test 6.5.1 PS3 wiring outside a fire enclosure complies with single fault testing in B.4, or be current limited per one of the permitted methods. P Annex F (F.3.3.8) Output terminals provided for supply of other equipment, except mains, supply are marked with a maximum rating or references to which equipment it is permitted to be connected. P Annex G (G.7.
Page 57 of 63 Report No.: CQASZ20210400194S IEC 62368-1 with U.S.A. National differences Clause Requirement + Test Result - Remark Verdict Consumer products designed or intended primarily for children 12 years of age or younger are subject to additional requirements in accordance with U.S. & Canadian Regulations. N/A Baby monitors additionally comply with ASTM F2951, Consumer Safety Specification for Baby Monitors. N/A Annex DVA (5.6.
Page 58 of 63 Report No.: CQASZ20210400194S IEC 62368-1 with U.S.A. National differences Clause Requirement + Test Result - Remark Verdict Annex DVA (G.4.2) Equipment with isolated ground (earthing) receptacles complies with NEC 250.146(D) and CEC 10-112 and 10-906(8). Annex DVA (G.4.3) Where a fuse is used to provide Class 2 or Class 3 current limiting, it is not operator-accessible unless it is non- interchangeable. P Annex DVA (G.5.
Page 59 of 63 Report No.: CQASZ20210400194S IEC 62368-1 with U.S.A. National differences Clause Requirement + Test Result - Remark Verdict Annex DVE (4.1.1) Some equipment, components, sub-assemblies and materials associated with the risk of fire, electric shock, or personal injury have component or material ratings in accordance with the applicable national (U.S. and Canadian) component or material requirements.
Page 60 of 63 Report No.: CQASZ20210400194S IEC 62368-1 with U.S.A. National differences Clause Requirement + Test Annex DVJ (10.6.1) Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements.
Page 61 of 63 Photo documentation Details of: External view Details of: External view Report No.
Page 62 of 63 Photo documentation Details of: External view Details of: Internal view Report No.
Page 63 of 63 Photo documentation Details of: PCB view Details of: PCB view The report end Report No.