Maintenance Manual LBI-38775S MASTR® III Base Station Application/Assembly Diagrams TABLE OF CONTENTS Title T/R SHELF............................................................... SYSTEM MODULE (Earlier) ................................. SYSTEM MODULE (Later) .................................... POWER MODULE ..................................................
TABLE OF CONTENTS TABLE OF CONTENTS Page SAFETY INFORMATION ..............................................................................................................................................3 INTRODUCTION ............................................................................................................................................................4 APPLICATIONS.............................................................................................................................
INTRODUCTION & APPLICATIONS SAFETY INFORMATION • • • • The means of disconnecting power from a station cabinet is the cabinet power supply plug. When conducting repair/maintenance, disconnect the cabinet power supply plug from the AC source. In European applications, equipment must be installed in a closed cabinet. Only replace components with components specified by M/A-COM Private Radio Systems.
INTRODUCTION & APPLICATIONS INTRODUCTION This manual (LBI-38775) contains information for the MASTR III Base Station, including application information, cable diagrams and parts list for the cabinet hardware. For additional information refer to the following manuals: 4 MANUAL NUMBER TITLE COMMENTS LBI-38636 Installation How to install including Interconnection Diagrams. AE/LZT 123 3242/1 Installation Installation, Configuration and Checkout for EDACS Basic or Level 1 Systems.
INTRODUCTION & APPLICATIONS APPLICATIONS LBI-38775S OPTION NUMBER APPLICATION ASSEMBLY DESCRIPTION SXCAIS 19D902845P1 Installation of One MASTR III Station in a 37" Indoor Cabinet SXRB1J 19D902845P2 Installation of R/R Shelf for MASTR III Station. SXSU3A 19D902845P3 Installation of Coax Switch.
INTRODUCTION & APPLICATIONS OPTION NUMBER APPLICATION ASSEMBLY DESCRIPTION 19D902845P21 Installation in 69" Indoor Cabinet or Open Rail Rack. SXMD3M 19D902845P22 Installation for Simulcast Stations. SXMD1S 19D902845P23 Installation and Modifications Instruction for RIC Telephone Interconnect. SXVT1B 19D902845P24 Modification for Station Receiver Voting for RS-232. SXCA1X 19D902845P25 Installation in 45" Weatherproof Cabinet. SXVT1L 19D902845P26 Modem Voting Installation.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET 19D902845P1 (19D902845, Sh. 1, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET 19D902845P1 (19D902845, Sh. 2, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET 19D902845P1 (19D902845, Sh. 3, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET 19D902845P1 (19D902845, Sh. 3A, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET 19D902845P1 (19D902845, Sh. 4, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET 19D902845P1 (19D902845, Sh. 5, Rev.
APPLICATION ASSEMBLY DIAGRAM T/R SHELF, SQUELCH OPERATED RELAY, DATA MODULE, AMPLIFIER MODULE & TRANSMIT ONLY STATION 19D902845P2, P7, P14, P19 & P32 (19D902845, Sh. 6, Rev.
APPLICATION ASSEMBLY DIAGRAM T/R SHELF, SQUELCH OPERATED RELAY, DATA MODULE, AMPLIFIER MODULE & TRANSMIT ONLY STATION 19D902845P2, P7, P14, P19 & P32 (19D902845, Sh. 7, Rev.
APPLICATION ASSEMBLY DIAGRAM COAX SWITCH ASSEMBLY 19D902845P3 (19D902845, Sh. 8, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET WITH DUPLEXER SHELF 19D902845P4 (19D902845,Sh. 9, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET WITH AUTOMOBILE BATTERY EMERGENCY POWER 19D902845P5 (19D902845, Sh. 10, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET WITH GEL CELL BATTERY EMERGENCY POWER 19D902845P6 (19D902845, Sh. 11, Rev.
APPLICATION ASSEMBLY DIAGRAM 37" INDOOR CABINET WITH GEL CELL BATTERY EMERGENCY POWER 19D902845P6 (19D902845, Sh. 12, Rev.
APPLICATION ASSEMBLY DIAGRAM 69" INDOOR CABINET WITH ONE STATION 19D902845P21 (19D902845, Sh. 15, Rev.
APPLICATION ASSEMBLY DIAGRAM 69" INDOOR CABINET WITH ONE STATION 19D902845P21 (19D902845, Sh. 15A, Rev.
APPLICATION ASSEMBLY DIAGRAM DETAIL “H” 69" INDOOR CABINET WITH ONE STATION 19D902845P21 (19D902845, Sh. 16, Rev.
APPLICATION ASSEMBLY DIAGRAM 69" INDOOR CABINET WITH ONE STATION 19D902845P21 (19D902845, Sh. 17, Rev.
APPLICATION ASSEMBLY DIAGRAM MASTR III STATION WITH MASTR II AUXILIARY RECEIVER 19D902845P8 (19D902845, Sh. 18, Rev.
APPLICATION ASSEMBLY DIAGRAM MASTR III TX P.A.
APPLICATION ASSEMBLY DIAGRAM MASTR III TX P.A.
APPLICATION ASSEMBLY DIAGRAM MASTR III STATION WITH MASTR III MULTIPLE RECEIVER 19D902845P10 (19D902845, Sh. 18A, Rev.
APPLICATION ASSEMBLY DIAGRAM 69" INDOOR CABINET WITH GETC SHELF 19D902845P9 (19D902845, Sh. 19, Rev.
APPLICATION ASSEMBLY DIAGRAM MASTR III BASE STATION WITH VOICE GUARD GETC MODULE 19D902845P11-P13 (19D902845, Sh. 20, Rev.
APPLICATION ASSEMBLY DIAGRAM MASTR III BASE STATION WITH VOICE GUARD GETC MODULE 19D902845P11-P13 (19D902845, Sh. 21, Rev.
APPLICATION ASSEMBLY DIAGRAM EDACS CABINET WITH ONE STATION 19D902845P15 (19D902845, Sh. 22, Rev.
APPLICATION ASSEMBLY DIAGRAM EDACS CABINET WITH MULTI-STATIONS 19D902845P16 (19D902845, Sh. 23, Rev.
APPLICATION ASSEMBLY DIAGRAM EDACS CABINET WITH MULTI-STATIONS 19D902845P16 (19D902845, Sh. 23A, Rev.
APPLICATION ASSEMBLY DIAGRAM EDACS MULTI-STATION CABINET WITH SIM SHELF 19D902845P17 (19D902845, Sh. 23D, Rev.
APPLICATION ASSEMBLY DIAGRAM MULTI-STATION ASSEMBLY 19D902845P16 (19D902845, Sh. 24, Rev.
APPLICATION ASSEMBLY DIAGRAM EXTERNAL REFFERENCE OSCILLATOR/DISTRIBUTION AMPLIFIER FOR NARROW BAND SYSTEMS 19D902845P18 & P31 (19D902845, Sh. 24A, Rev.
LBI-38775S (19D902845, Sh. 25, Rev.
APPLICATION ASSEMBLY DIAGRAM RIC EQUIPMENT 19D902845P23 (19D902845, Sh. 26, Rev.
APPLICATION ASSEMBLY DIAGRAM STATION RECEIVER VOTING FOR RS-232 19D902845P24 (19ED902845, Sh. 27, Rev.
APPLICATION ASSEMBLY DIAGRAM EDACS SIMULCAST STATION 19D902845P22 & P33 (19D902845, Sh. 28, Rev.
APPLICATION ASSEMBLY DIAGRAM 45" WEATHER PROOF CABINET 19D902845P25 (19D902845, Sh. 29, Rev.
APPLICATION ASSEMBLY DIAGRAM MODEM VOTING & CNI INSTALLATION 19D902845P26 & P27 (19D902845, Sh. 30, Rev.
APPLICATION ASSEMBLY DIAGRAM 3 EDACS ADVANTAGE STATIONS 19D902845P29 (19D902845, Sh. 31, Rev.
APPLICATION ASSEMBLY DIAGRAM 3/5 CHANNEL EDACS SYSTEM WITH COMBINER AND MULTICOUPLER CHANNEL 4 & 5 19D902845P28 & P30 (19D902845, Sh. 32, Rev.
APPLICATION ASSEMBLY DIAGRAM 3/4 CHANNEL EDACS SYSTEM WITH COMBINER AND MULTICOUPLER 19D902845P33 (19D902845, Sh. 32A, Rev.
APPLICATION ASSEMBLY DIAGRAM GPS SIMULCAST STATION GETC 19D902845P33 (19D902845, Sh. 33, Rev.
HARNESS ASSEMBLY HARNESS 19C337792P1 (19C337792, Sh. 1, Rev. 2) (19B803755, Sh. 1, Rev.
HARNESS ASSEMBLY 19B801454P16 & P17 (19B801454, Sh. 10, Rev. 27) 19B801454P43 (19B801454, Sh. 23, Rev. 27) 19B801454P17 & P18 (19B801454, Sh. 11, Rev. 27) 19B801454P19 & P20 (19B801454, Sh. 12, Rev. 27) 19B801454P24 CONTROL CABLE ASSEMBLY (PART OF POWER AMPLIFIER) 19B801739P1 (19B801454, Sh. 15, Rev. 27) (19B801739, Sh 1, Rev.
HARNESS ASSEMBLY POWER CABLE (PART OF POWER AMPLIFIER) 19B801937P1 (19B801937, Sh. 1, Rev. 2) 344A3052P1 (344A3052, Sh. 1, Rev. 2) 19B235871P1 (19B237871, Sh. 1, Rev.
EXTENDER BOARDS CONTROL EXTENDER BOARD 188D5338G1 RF EXTENDER BOARD 188D5338G2 (188D5338, Sh. 1, Rev.
PARTS LISTE MULTI PURPOSE MODULE 193D1094G1 (193D1094, Sh. 1, Rev.
GROUNDING STRAP INSTALLATION INSTRUCTIONS ISOLATOR KIT 350A130G1 The MASTR III 800 MHz T/R shelf is mounted in the station cabinet using Isolator Kit 350A1350G1, which provides rubber isolators, needed at 800 MHz to dampen vibrations. This kit also provides grounding strap SXA 104 7504/1. This grounding strap is used with the lower isolator on the right rail only. As shown above, this strap (Item 8) slips over each end of the isolator studs with the loop oriented toward the outside cabinet wall.
PARTS LISTE PARTS LIST MASTR III STATION Issue 4 SYMBOL PART NO.
M/A-COM Wireless Systems 3315 Old Forest Road Lynchburg, Virginia 24501 (Outside USA, 434-385-2400) Toll Free 800-528-7711 www.macom-wireless.com Printed in U.S.A.