PUBLICATION NUMBER: 10515-0372-4200 DECEMBER 2009 Rev. - UNITY™ XG-100P FULL-SPECTRUM MULTIBAND RADIO OPERATIONS MANUAL Information and descriptions contained herein are the property of Harris Corporation. Such information and descriptions may not be copied or reproduced by any means, or disseminated or distributed without the express prior written permission of Harris Corporation, RF Communications Division, 1680 University Avenue, Rochester, New York 14610-1887.
This product was developed using GEOTRANS, a product of the National Geospatial Intelligence Agency and U.S. Army Engineering Research and Development Center. Use of this software does not indicate endorsement or approval of the product by the Secretary of Defense or the National Geospatial Intelligence Agency.
XG-100 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EQUIPMENT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STORAGE GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 12 BASIC SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ASSEMBLE THE RADIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REMOVING THE BATTERY . . . . . . . . . . . . . . . . . . . .
XG-100 LOAD KEYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOAD KEYGROUPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZEROIZE ALL FROM RADIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ZEROIZE KEYS USING KVL 3000 PLUS . . . . . . . . . . . . . . . . . . . . . ZEROIZE KEYGROUPS USING KVL 3000 PLUS . . . . . . . . . . . . . . ZEROIZE ALL FROM KVL 3000 PLUS . . . . . . . . . . . . . . . . . . . . . . .
XG-100 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 MARINE FREQUENCIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 123 GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XG-100 This page intentionally left blank.
WARNING - Before operating the XG-100P radio, read the safety and RF exposure guidelines contained in safety booklet, 105150372-4000, included with your radio. The XG-100P has been tested and complies with the Federal Communications Commission (FCC) RF exposure limits for “Occupational Use Only.
CHANNEL KNOB POWER / VOLUME KNOB ENCRYPTION SWITCH MICROPHONE* (REAR) ANTENNA CONNECTOR EMERGENCY BUTTON INDICATOR LED TOP DISPLAY SPEAKER MICROPHONE* BANK SELECTOR FRONT DISPLAY PROGRAMMABLE HOT KEY SOFT-KEY DISPLAYS PTT BUTTON SOFT KEYS PROGRAMMABLE BUTTONS SELECT/SHORTCUT BUTTON BATTERY NAVIGATOR KEYPAD** *DUAL MICROPHONE SYSTEM USED FOR NOISE CANCELLATION ** USE AS HOME KEY FOR NAVIGATION BACK TO MAIN SCREEN 10 CL-0372-4200-0007B
INTRODUCTION Section 1 Page Equipment Description . . . . . . . . . . . . . . .12 Storage Guidelines . . . . . . . . . . . . . . . . . .
XG-100 I NTRODUCTI ON 1 EQUIPMENT DESCRIPTION Your XG-100P provides full-spectrum multiband coverage: • • 136 to 174 MHz, VHF, 1 watt, 2 watts, 3 watts, 6 watts output • 762 to 870 MHz, 700/800 bands, 0.
BASIC SETUP Section 2 Page Assemble the Radio . . . . . . . . . . . . . . . . .14 Removing the Battery . . . . . . . . . . . . . . . .16 Removing Optional Belt Clip . . . . . . . . . . .
XG-100 BASI C SETUP ASSEMBLE THE RADIO 2 CAUTION: Do not overtighten the antenna as damage could result. WARNING: Only use Harris charger approved for battery chemistry. Injury could occur from improper charger use. a. Make sure batteries are charged per the charger manual (refer to 10515-0372-4010, supplied with the charger). b. To attach optional clip, slide into groove in back of the radio above battery compartment. c.
XG-100 BASI C SETUP BELT CLIP (OPTIONAL) BATTERY 2 ANTENNA CL-0372-4200-0002 15
XG-100 BASI C SETUP REMOVING THE BATTERY To remove, press and hold tab, lift battery clip, then pull battery up and out of the radio. 2 CL-0372-4200-0009 REMOVING OPTIONAL BELT CLIP Remove the battery before removing the clip. To remove belt clip, press and hold tab towards top of battery, then slide out of groove in back of the radio.
BASIC OPERATIONS Section 3 Page XG-100P Controls. . . . . . . . . . . . . . . . . . .18 Top Display . . . . . . . . . . . . . . . . . . . . . . . .20 Main Display . . . . . . . . . . . . . . . . . . . . . . .21 Menu Navigation . . . . . . . . . . . . . . . . . . . .22 Before First Time Use . . . . . . . . . . . . . . . .23 Power On and Set Volume . . . . . . . . . . . .23 Select Channel Bank . . . . . . . . . . . . . . . .24 Select Channel Using Knob . . . . . . . . . . .24 Turn Encryption On or Off . .
XG-100 BASI C OPERATI ONS XG-100P CONTROLS 1. CHANNEL KNOB 3 2. POWER / VOLUME KNOB 3. ENCRYPTION SWITCH 4. MICROPHONE* (REAR) 10. ANTENNA CONNECTOR 11. EMERGENCY BUTTON 12. INDICATOR LED 13. TOP DISPLAY 14. SPEAKER 15. MICROPHONE* 5. BANK SELECTOR 6. PROGRAMMABLE HOT KEY 7. PTT BUTTON 8. PROGRAMMABLE BUTTONS 9. BATTERY 16. FRONT DISPLAY 17. SOFT-KEY DISPLAYS 18. SOFT KEYS 19. SELECT/SHORTCUT BUTTON 20. NAVIGATOR 21.
XG-100 BASI C OPERATI ONS Table 1. XG-100P Controls, Indicators, and Connectors Key Control/Indicator Function 1 Channel Knob 2 Power/Volume Knob Used to select one of 16 channels 3 Encryption Switch Selects between encrypted and unencrypted operation. Ø - Encryption O - No Encryption 4 Microphone (Rear) Used with microphone on the front of the radio to form a dual microphone system that is used for noise cancellation. Noise cancellation improves the quality of transmitted voice.
XG-100 BASI C OPERATI ONS Table 1. XG-100P Controls, Indicators, and Connectors (Continued) Key 3 Control/Indicator Function 16 Front Display 17 Soft-Key Displays Front display shows complete status and radio menus. 18 Soft Keys 19 Select/Shortcut Button Used to select menu highlighted by navigator. Also used for shortcut menu from main screen (Shortcut Menu). 20 Navigator Provides up, down, left, right menu navigation. Also used for select and shortcut menu access.
XG-100 BASI C OPERATI ONS MAIN DISPLAY The main display appears after power up or after exiting from the menus.
XG-100 BASI C OPERATI ONS MENU NAVIGATION 3 MAIN DISPLAY PRESS FOR MENU PRESS FOR CH INFO MAIN MENU 1 2 3 PRESS 5 5 6 THEN SELECT 7 8 9 KEYPAD 1 - 9 CAN ALSO BE USED FOR DIRECT ACCESS (EXAMPLE: PRESS 4 FOR ZONE) PRESS SUBMENU THEN SELECT CL-0372-4200-0006C 22
XG-100 BASI C OPERATI ONS BEFORE FIRST TIME USE Make sure XG-100P has: • • • • • Fully charged battery Antenna attached Mission plan and radio programmed using the CPA 3 Keys are loaded Mission plan is activated using radio menus POWER ON AND SET VOLUME The power switch and volume control are within the same control. 1. Turn clockwise to power on XG-100P. 2. Set to desired volume level.
XG-100 BASI C OPERATI ONS SELECT CHANNEL BANK The XG-100P can be programmed with up to 1250 channels, 48 channels per zone, with 16 channels in each of the three banks: • • • 3 Bank A - Channel A1 - A16 Bank B - Channel B1 - B16 Bank C - Channel C1 - C16 1. Use to set bank. 1. Use to set channel 1 - 16.
XG-100 BASI C OPERATI ONS TURN ENCRYPTION ON OR OFF Refer to Create Keys and Load Keys. 1. Use encryption: • • to set 3 Ø - Encryption O - No encryption Key appears when encryption is used for channel that is digital and programmed to be encrypted. Analog channels do not show the encryption key. NOTE: When encryption is turned on and you use a digital channel not configured for encryption, the radio will not allow PTT. The screen displays CLEAR TX DENIED.
XG-100 BASI C OPERATI ONS SELECT ZONE USING MENUS A zone is a group of channels, and can be programmed by agency or geographical region. For example, a zone could be for fire, police, New York, Los Angeles, etc. 3 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select ZONE or just press . A mission plan could have up to 64 zones, independent of banks or channels. ZONE 26 3. Use to view zone.
XG-100 BASI C OPERATI ONS 4. Use zone. to highlight 5. Use to select highlighted zone. ZONE 3 If VIEW ZONES was selected, this screen appears allowing you to view the channels in the zone. ZONE 6. Use to scroll through the zones. 7. Use to select highlighted zone. New zone appears.
XG-100 BASI C OPERATI ONS MAKE AN INDIVIDUAL CALL An individual call is used to make a call to one radio as opposed to a group of radios. An individual call can only be made on digital channels. On the receiving radio, the calling station name will appear in the activity area. 3 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select CALL or just press . 5 JK L 3. 28 Use to highlight and select INDIVIDUAL CALL.
XG-100 BASI C OPERATI ONS 4. Use to highlight and select individual. 3 5. Use PTT call. to make the 6. To end call, use select END CALL.
XG-100 BASI C OPERATI ONS MAKE A PRIORITY CALL A priority call is used to make a call on the priority channel. Priority calls can only be made on digital channels. 3 30 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select CALL or just press . 5 JK L 3. Use to highlight and select ENABLE for PRIORITY MODE. 4. Use screen.
XG-100 BASI C OPERATI ONS 5. Use PTT call. to make the PRIORITY CHANNEL APPEARS WHEN KEYED 3 MAIN SCREEN SELECT A NEW TALKGROUP A talkgroup is a group of radios that you would want to have private conversations with. These groups could be divided into areas such as state, region, county, or large special events. A talkgroup call can only be made on digital channels. On the receiving radio, the calling station name will appear in the activity area. 1 2 3 4 5 6 7 8 9 1.
XG-100 BASI C OPERATI ONS 3. Use to highlight and select CHANGE TLKGRP. 4. Use to highlight and select talkgroup. 5. Use screen. 6. Use PTT call.
XG-100 BASI C OPERATI ONS USE TALKAROUND TO BYPASS REPEATER You can bypass the repeater system to communicate directly with other radios on your current channel’s receive frequency. This is useful if you are out of range of a repeater or if a repeater is busy. You will need to be in range of the other radio. 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select CALL or just press 5 . 3 JK L 3. Use to change TALKAROUND MODE to ENABLED.
XG-100 BASI C OPERATI ONS TALKAROUND ENABLED 3 34 Talkaround icon appears. Calls will now be made on the receive frequency until you disable talkaround mode.
XG-100 BASI C OPERATI ONS START SCAN This procedure assumes that the scan list has been added and is not in active scan. Refer to Set up Scan or Stop Scan. NOTE: For shortcut method of starting scan, refer to Start or Stop Scan (Shortcut Menu). 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select SCAN or just press 2 . AB C 3. Use to highlight SCAN METHOD. 4. Use to select ZONE SCAN or CUSTOM SCAN for scan method (Zone Scan vs Custom Scan).
XG-100 BASI C OPERATI ONS 5. Use to highlight START SCAN. Text changes to red STOP SCAN. Radio is scanning at this point. Additional scanning indications can be seen in the next step. 3 6. SCANNING DISPLAY MAIN SCREEN 36 Use menu.
XG-100 BASI C OPERATI ONS STOP SCAN This procedure is used to stop an active scan. Refer to Start Scan. 1. 1 2 3 4 5 6 7 8 9 2. At main display, use for main menu. 3 Use to highlight and select SCAN or just press 2 . AB C 3. Use to highlight STOP SCAN. 4. Use menu.
XG-100 BASI C OPERATI ONS NUISANCE DELETE A channel can temporarily be deleted from the scan list if it is not a priority channel. The radio must be scanning for nuisance delete. 3 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select SCAN or just press 2 . AB C 3. 38 Use to highlight and select ZONE LISTS or CUSTOM LISTS.
XG-100 BASI C OPERATI ONS Custom scan configuration screens are shown here. Zone scan configuration is similar. 4. Use scan list. to highlight 3 indicates the active scan list. 5. Use to select OPTIONS. 6. Use to highlight and select VIEW/EDIT. 7. Use channel. 8. Use to select OPTIONS. 9. Use to highlight and select NUISANCE. to highlight Nuisance channel will not be scanned. Channel will return to scan list when you cycle radio power or activate mission plan.
XG-100 BASI C OPERATI ONS 10. Use list. to exit channel 11. Use to exit zone or custom lists display. 3 SCANNING DISPLAY MAIN SCREEN VIEW GPS INFORMATION You can use the internal Global Positioning System (GPS) receiver to view your position and satellite information. Remember, GPS: • Signal is greatly diminished inside buildings, tunnels, heavily forested areas etc. • Requires unobstructed view of the sky. GPS may not work at all under some materials, especially metal. 1.
XG-100 BASI C OPERATI ONS GPS TIME* GPS STATUS * WHEN TRACKING 1 2 3 4 5 6 7 8 9 2. Use to highlight and select GPS or just press . 3 You can observe GPS status: • GPS TRACKING - GPS has acquired satellite signal. GPS time appears on top of display. • GPS SEARCHING - GPS has not acquired. Harris logo appears on top of display if GPS has not tracked after last power up of the radio. • LAST KNOWN POS - GPS acquired since power up has lost signal.
XG-100 BASI C OPERATI ONS EMERGENCY OPERATION The XG-100P can be programmed to enable emergency mode. ‘Emergency’ text displays on dispatcher console if an emergency signal is received from another XG-100P on a digital channel. 3 Receiving an Emergency Call When receiving an Emergency Call, an alert beep is present (if tones are enabled) and an emergency indication is displayed. When receiving an emergency on a digital channel, the Unit Identification (ID) appears in the activity area.
XG-100 BASI C OPERATI ONS Declaring an Emergency Call 1. Press . 3 For digital channels, the radio transmits talkgroup or radio ID to dispatch console or receiving radio. The radio will go through transmit and receive cycles if configured. You can speak into the microphone while the radio is transmitting or press PTT to talk. 2. To exit emergency, either power cycle the radio or select EXIT EMERGENCY from the call menu.
XG-100 BASI C OPERATI ONS 3 This page intentionally left blank.
ADVANCED OPERATIONS Section 4 Page Create Keys . . . . . . . . . . . . . . . . . . . . . . .46 Load Keys . . . . . . . . . . . . . . . . . . . . . . . . .48 Load Keygroups . . . . . . . . . . . . . . . . . . . .50 Zeroize All from Radio . . . . . . . . . . . . . . .52 Zeroize Keys Using KVL 3000 Plus . . . . .53 Zeroize Keygroups Using KVL 3000 Plus .55 Zeroize All from KVL 3000 Plus . . . . . . . .57 Activate/View Mission Plan . . . . . . . . . . . .58 CH INFO Menu . . . . . . . . . . . . . . . . . . .
XG-100 ADVANCED OPERATI ONS CREATE KEYS Refer to the Motorola KVL 3000 Plus Key Variable Loader (KVL) User's Guide for advanced programming and setup instructions. Create Key in the KVL 3000 Plus You can generate a single Type-3 key in the KVL 3000 Plus key loading device: 4 46 a. Turn on the KVL 3000 Plus. b. Select KEYS. c. Select NEW. d. Enter a number between 00001 and 04095 or between 61440 and 65535 at Common Key References (CKR) prompt. The number must be unique on the KVL 3000 Plus. e.
XG-100 ADVANCED OPERATI ONS Create Keygroup in the KVL 3000 Plus You can generate a group of Type-3 keys in the KVL 3000 Plus: a. Turn on the KVL 3000 Plus. b. Select Esc. c. Select GROUPS. d. Select NEW. e. Enter a Group Name (up to seven characters). 4 NOTE The XG-100 can store both DES-OFB and AES-256 keys, however, only one type may be loaded at a time. A keyset must contain only DES-OFB or only AES-256 keys. f. Select CKRs from the programmed list until all desired CKRs are selected. g.
XG-100 ADVANCED OPERATI ONS LOAD KEYS Type 3 Digital Encryption Standard Output Feedback (DES-OFB) and Advanced Encryption Standard, 256-bit (AES-256), encryption methods are supported. The Type 3 Encryption keys are loaded via a Motorola KVL 3000 Plus device using Telecommunications Industry Association (TIA)/Project P25 (P25) key fill device protocol. Make sure that valid keys have been created and stored in the KVL 3000 Plus before proceeding. 4 1. Power on KVL 3000 Plus. 2.
XG-100 ADVANCED OPERATI ONS At the KVL 3000 Plus: 4. Select TARGET. 5. Select LOAD. 6. Select KEY. Esc Ctrl Shift Pwr Back 1 2 3 A 4 5 6 B 7 8 9 C G F E D 7. Using ◄or ►, select: • • DES-OFB key 4 AES-256 key 8. Press LOAD. 9. Verify that the KVL 3000 Plus screen displays LOADED SUCCESSFULLY OK. 10. Select OK on the KVL 3000 Plus. 11. Repeat for additional keys. 12. Remove the KVL 3000 Plus cable from the radio.
XG-100 ADVANCED OPERATI ONS LOAD KEYGROUPS Make sure that valid keygroups have been created and stored in the KVL 3000 Plus before proceeding. 1. Power on KVL 3000 Plus. 2. Connect KVL 3000 Plus to side connector using a 12082-0400-A1 cable. 3.
XG-100 ADVANCED OPERATI ONS At the KVL 3000 Plus: 4. Select TARGET. 5. Select LOAD. 6. Select GROUP. Esc Ctrl Shift Pwr Back 1 2 3 A 4 5 6 B 7 8 9 C G F E D 7. Using ◄or ►, select: • • DES-OFB keygroups 4 AES-256 keygroups 8. Press LOAD. 9. Verify that the KVL 3000 Plus screen displays LOADED SUCCESSFULLY OK. 10. Select OK on the KVL 3000 Plus. 11. Repeat for additional groups. 12. Remove the KVL 3000 Plus cable from the radio.
XG-100 ADVANCED OPERATI ONS ZEROIZE ALL FROM RADIO It may be necessary to remove the keys because of compromise or expiration. 1. At main display, use for main menu. 2. Use to highlight and select SECURITY or just press . 3. Use to highlight and select ZEROIZE KEYS. 4. Use to highlight and select YES if you want to remove the keys.
XG-100 ADVANCED OPERATI ONS 5. Use to select OK. 4 ZEROIZE KEYS USING KVL 3000 PLUS Refer to the KVL 3000 Plus User’s Guide for advanced instructions. 1. Power on KVL 3000 Plus. 2. Connect KVL 3000 Plus to side connector using a 12082-0400-A1 cable. SIDE CONNECTOR CAUTION: Ensure correct keyset is selected. 3.
XG-100 ADVANCED OPERATI ONS At the KVL 3000 Plus: 4. Select TARGET. 5. Select ZERO. 6. Select KEY. 7. Using ◄or ►, select the key to remove from the radio. 8. Press ZERO. 9. Verify that the KVL 3000 Plus screen displays ZEROIZED SUCCESSFULLY OK. Esc Ctrl Shift 4 Pwr Back 1 2 3 A 4 5 6 B 7 8 9 C G F E D 10. Select OK on the KVL 3000 Plus. 11. Repeat for additional keys. 12. Remove the KVL 3000 Plus cable from the radio. 13. Set to O to remove all AES and DES keys.
XG-100 ADVANCED OPERATI ONS ZEROIZE KEYGROUPS USING KVL 3000 PLUS Refer to the Motorola KVL 3000 Plus User's Guide for advanced instructions. 1. Power on KVL 3000 Plus. 2. Connect KVL 3000 Plus to side connector using a 12082-0400-A1 cable. 4 SIDE CONNECTOR CAUTION: Ensure correct keyset is selected. 3.
XG-100 ADVANCED OPERATI ONS At the KVL 3000 Plus: 4. Select TARGET. 5. Select ZERO. 6. Select GROUP. 7. Using ◄or ►, select the key to remove from the radio. 8. Press ZERO. 9. Verify that the KVL 3000 Plus screen displays ZEROIZED SUCCESSFULLY OK. Esc Ctrl Shift 4 Pwr Back 1 2 3 A 4 5 6 B 7 8 9 C G F E D 10. Select OK on the KVL 3000 Plus. 11. Repeat for additional keys. 12. Remove the KVL 3000 Plus cable from the radio. 13. Set to O to remove all AES and DES keys.
XG-100 ADVANCED OPERATI ONS ZEROIZE ALL FROM KVL 3000 PLUS Refer to the KVL 3000 Plus User's Guide for advanced programming and setup instructions. 1. Power on KVL 3000 Plus. 2. Connect KVL 3000 Plus to side connector using a 12082-0400-A1 cable. 4 SIDE CONNECTOR This appears on radio. All AES and DES keys are zeroized regardless of selection. At the KVL 3000 Plus: 3. Select TARGET. 4. Select ZERO. 5. Select ALL. Esc Ctrl Shift Pwr Back 1 2 3 A 4 5 6 B 7 8 9 C G F E D 6.
XG-100 ADVANCED OPERATI ONS 9. Remove the KVL 3000 Plus cable from the radio. 4 ACTIVATE/VIEW MISSION PLAN Mission plans contain radio programming information such as frequencies, channels, stations, and talkgroups. Up to 10 different mission plans can be stored in the radio, but only one can be activated at one time. 58 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select PROGRAM or just press .
XG-100 ADVANCED OPERATI ONS 3. Use to highlight and select mission plan. indicates the active mission plan. 4 4. Use to select OPTIONS. 5. Use select: to highlight and • ACTIVATE PLAN to load the plan for use by the radio. • VIEW PLAN INFO - to view mission plan information. If plan is activated, radio displays series of screens indicating status, ending with a PLAN COMPLETE followed by name of plan. 6. Use to select OK.
XG-100 ADVANCED OPERATI ONS If plan is being viewed, radio displays the plan’s filename and file size. Plan information appears if field was filled out in the CPA. 7. Use BACK. to select 8. Repeatedly use exit menus. 9. New plan appears if activated. 4 NEW PLAN to MAIN SCREEN CH INFO MENU The Channel Information (CH INFO) menu displays information about the currently selected channel. 1. 60 At main display, use for channel information menu.
XG-100 ADVANCED OPERATI ONS 2. Use to scroll through the programmed channel settings. 4 3. Additional settings can be found by scrolling down. 4. If a channel was programmed to allow editing by properly trained operator, you will be able to use the steps that follow. 5. Use CHAN. 6. Enter password to select EDIT NOTE: Password remains active until power cycle. Refer to Edit Channel.
XG-100 ADVANCED OPERATI ONS SETTINGS MENU The settings menu allows you to change global radio settings such as audio, display, and clock. 1. At main display, use for main menu. 2. Use to highlight and select SETTINGS or just press . 3. Use setting.
XG-100 ADVANCED OPERATI ONS 4. Additional settings can be found by scrolling down. 4 5.
XG-100 ADVANCED OPERATI ONS Audio Settings Set audio settings such as speaker mute, noise cancellation, PTT, etc. 4 64 1. Enter Settings Menu. 2. Use to highlight and select AUDIO SETTINGS.
XG-100 ADVANCED OPERATI ONS 3. Use to change settings as desired: • 4. SPEAKER - Speaker audio can be muted or unmuted. The radio can be used with a wired lapel microphone. • NOISE CANCELLATION Enable or disable noise cancellation. Noise cancellation reduces background noise during transmit. • PTT - Enable or disable Push-To-Talk (PTT). Disable to prevent accidental keying, such as when radio is in holster or you are getting into a car. • TONES - Enable or disable alert tones (Table 1).
XG-100 ADVANCED OPERATI ONS Table 1. Alert Tones Description Ready To Talk Tone Unencrypted (Analog FM or P25 digital) After a PTT is pressed, this control enables the radio to produce an audible indication (tone) for you to begin speaking into the microphone. Medium tone for 25 ms Ready to Talk Tone Encrypted P25 digital After a PTT is pressed, this control enables the radio to produce an audible indication (tone) for you to begin speaking into the microphone.
XG-100 ADVANCED OPERATI ONS Table 1. Alert Tones Tone Sound/ Duration Description Maximum transmit duration expires Maximum transmit duration is exceeded. Low tone for 75 ms Low Battery Alarm Alarm sounds upon initial detection of low battery and every 30 seconds thereafter. Tone stops upon detection of a battery charging state. Sequence of tones: Emergency Call Received Radio is receiving an emergency call or priority call.
XG-100 ADVANCED OPERATI ONS Display Settings 4 68 1. Enter Settings Menu. 2. Use to highlight and select DISPLAY SETTINGS.
XG-100 ADVANCED OPERATIONS 3. Use to change settings as desired: • FRONT BACKLIGHT Turn front display backlight on, off, or momentary. • FRONT BRIGHTNESS - Set brightness level of front display. A level of 0 does not turn off front display. • TOP ORIENTATION Set orientation of top display to be viewed from radio FRONT, BACK or AUTO. 4 When AUTO is used, the XG-100P changes top display to be viewed from back if an external microphone or speaker is attached.
XG-100 ADVANCED OPERATI ONS GPS Settings 1. Enter Settings Menu. 2. Use to highlight and select GPS SETTINGS. 3. Use to change settings as desired: 4 70 • GPS - Enable or disable internal GPS. • LINEAR UNITS - Set unit of measurement of displayed linear units: STATUTE, METRIC, or NAUTICAL. • ANGULAR UNITS Set unit of measurement of displayed linear units: CARDINAL, DEGREES, or MILS.
XG-100 ADVANCED OPERATI ONS 4. Use to exit menu. Bluetooth Bluetooth settings only appear if enabled in the CPA. 1. Enter Settings Menu. 2. Use to highlight and select BLUETOOTH. 3. Use to set ENABLED to YES. 4. Use to select PAIRING MGMT. This is used to pair the radio with another bluetooth device.
XG-100 ADVANCED OPERATI ONS 5. Make sure device being paired is powered on and set to pair with the XG100P. If no devices are found and bluetooth is enabled, ADD NEW appears in the lower right corner. Otherwise, OPTIONS appears. 4 6. Use to ADD NEW or OPTIONS. If OPTIONS was selected, the options menu appears. 7. Use to highlight and select ADD NEW. Device being paired should be displayed. 72 8. Use to REFRESH device list if device does not appear. 9. Use to highlight and select device.
XG-100 ADVANCED OPERATI ONS For Bluetooth® 2.0 devices, a passkey screen appears. 10. Enter unit ID. 11. Use to select OK. 4 For Bluetooth® 2.1 devices, an accept/deny screen appears. 12. Use to select ACCEPT. Progress is then displayed. A message appears when pairing is complete. 13. Use to select OK.
XG-100 ADVANCED OPERATI ONS Paired device is then displayed under pair devices list. 14. Use to select OPTIONS. 4 15. Use to highlight and select choices. If INFO was selected, the paired device information screen appears. 16. Use 74 to exit menu.
XG-100 ADVANCED OPERATI ONS 17. Use to highlight and select FRIENDLY NAME. This is the name of device being paired. The friendly name used by the CPA will overwrite this setting. 4 18. Enter name for device. 19. Use 20. Use to select OK. to exit menu.
XG-100 ADVANCED OPERATI ONS Clock Settings 1. Enter Settings Menu. 2. Use to highlight and select CLOCK SETTINGS. 3. Use to change settings as desired: 4 • DISPLAY TIME - Set 12 or 24 hour time display format. • TIME ZONE - Set time zone relative to Universal Time Coordinated (UTC). 4. Use to exit menu. 1. Enter Settings Menu. 2. Use to highlight and select BATTERY SETTINGS.
XG-100 ADVANCED OPERATI ONS WARNING: Use only Harris approved batteries. Injury could occur from using incorrect battery. 3. 4 Use to change settings as desired: • LITHIUM ION - For accurate battery indication on front and top displays, if battery attached to rear of radio is a Lithium-ION (Li-ION) type. • NIMH - For accurate indication on front and top displays, if battery attached to rear of radio is a Nickel Metal Hydride (Ni-MH) type.
XG-100 ADVANCED OPERATI ONS • 4 4. Use ALKALINE - For accurate battery indication on front and top displays, if battery attached to rear of radio is clamshell containing disposable AA alkaline batteries. to exit menu. SHORTCUT MENU The shortcut menu provides menus for quickly accessing commonly used functions. 1. 78 At main display, use center button to display the shortcut menu.
XG-100 ADVANCED OPERATI ONS 2. Use , 2 AB C , 5 , or select task: JK L • , , to 1. START/STOP SCAN - Start or Stop Scan (Shortcut Menu) START SCAN appears if not scanning. STOP SCAN appears if scanning • 2. START MONITOR Monitor and Squelch Types. This is grayed out if radio is scanning. • 3. NUISANCE DEL Nuisance Delete. This is grayed out if not scanning • 4. MUTE SPKR Mute/Unmute Speaker • 5. LOCK KEYPAD Lock Keypad • 6.
XG-100 ADVANCED OPERATI ONS Start or Stop Scan (Shortcut Menu) 1. Enter Shortcut Menu. 2. To start scan, use to highlight and select START SCAN. START SCAN and NUISANCE DEL are grayed out in emergency mode. NUISANCE DEL is not grayed out when scanning. 4 3. 80 To stop scan, use to highlight and select STOP SCAN.
XG-100 ADVANCED OPERATI ONS Monitor and Squelch Types The monitor function allows you to temporarily turn off selected squelch to monitor for traffic that may not normally break squelch. Squelch used depends on an analog or digital channel. For analog channels, there is: • • Noise squelch - any received signal breaks squelch. • Continuous Digital Coded Squelch (CDCSS) - squelch is selective based on tone code. Continuous Tone Coded Squelch (CTCSS) - squelch is selective based on tone code.
XG-100 ADVANCED OPERATI ONS Nuisance Delete You can temporarily removed currently received channel from scan list. This choice is grayed out if the radio is not scanning. 4 82 1. Enter Shortcut Menu. 2. Use to select NUISANCE DEL while receiving channel you wish to temporarily remove from scan list.
XG-100 ADVANCED OPERATI ONS Mute/Unmute Speaker You can mute or unmute the front panel speaker. 1. Enter Shortcut Menu. 2. Use to select MUTE SPKR if speaker is not muted. 3. 4 Use to select UNMUTE SPKR if speaker is muted.
XG-100 ADVANCED OPERATI ONS Lock Keypad You can lock the keypad to prevent accidental operations from incorrect keypad press. 1. Enter Shortcut Menu. 2. Use to select LOCK KEYPAD. 3. Use to unlock keypad. Make sure exact sequence of ◄,►, ▼, and ▲ are used. 4 There must be no more than three seconds between key presses. Power cycling radio will not unlock the radio.
XG-100 ADVANCED OPERATI ONS Flip Top Display The top display can be flipped to suit your viewing direction. 1. Enter Shortcut Menu. 2. Use to select FLIP TOP DISPLAY. 4 Top display toggles between front and rear display orientation. SET UP SCAN These procedures are used to set up the scan list, home channels, and priority channels. Refer to Start Scan. 1 2 3 4 5 6 7 8 9 1. At main display, use for main menu. 2. Use to highlight and select SCAN or just press 2 .
XG-100 ADVANCED OPERATI ONS 3. Use to highlight and select ZONE LISTS or CUSTOM LISTS. 4. Proceed to: 4 • • • • • Add New Scan List • • Delete Scan List Edit Scan List Priority 1 Channel Rename Scan List Set or Remove Priority (PRI) Set Active Scan List Zone Scan vs Custom Scan A zone scan list consists of all channels in a zone. The zone scan list is automatically created while generating a mission plan with the Communications Planning Application (CPA).
XG-100 ADVANCED OPERATI ONS Add New Scan List Only a custom scan list can be added under CUSTOM SCAN CFG. 1. Enter Set up Scan. 2. Use to highlight ADD SCAN LIST. 4 The radio holds a maximum of 10 scan lists at one time. ADD SCAN LIST option is removed once 10 scan lists are entered into the radio. 3. Use scan list. to highlight new 4. Use to select OPTIONS. 5. Use to highlight and select VIEW/EDIT. 6. Use channel. 7. Use to select OPTIONS.
XG-100 ADVANCED OPERATI ONS 8. Use to highlight EDIT SCAN LIST. 9. Use to select channel or zone. 4 GRAYED OUT IS NOT IN SCAN LIST GRAYED OUT IS NOT IN SCAN LIST 10. Use to toggle channel selection in scan list. 11. Alternatively, use select OPTIONS. to 12. Then use to select ADD CHAN or DELETE CHAN. 88 13. Use list. to exit channel 14. Use to exit scan list.
XG-100 ADVANCED OPERATI ONS Edit Scan List Custom scan configuration screens are shown here. Zone scan configuration is similar. 1. Enter Set up Scan. 2. Use scan list. 3. Use to select OPTIONS. 4. Use to highlight and select VIEW/EDIT. 5. Use channel. 6. Use to select OPTIONS.
XG-100 ADVANCED OPERATI ONS 7. Use to highlight EDIT SCAN LIST. 8. Use channel. 9. Use to toggle channel selection in scan list. 4 GRAYED OUT IS NOT IN SCAN LIST GRAYED OUT IS NOT IN SCAN LIST to select 10. Alternatively, use select OPTIONS. to 11. Then use to select ADD CHAN or DELETE CHAN. 90 12. Use list. to exit channel 13. Use to exit scan list.
XG-100 ADVANCED OPERATI ONS Priority 1 Channel The priority 1 channel is the channel that is currently selected using the channel knob on top of the radio. Rename Scan List You can rename a newly created or existing scan list. You cannot rename zone scan lists. 1. Enter Set up Scan. 2. Use scan list. 3. Use to select OPTIONS. 4. Use to highlight and select RENAME LIST. 5. Use 4 to highlight to select OK.
XG-100 ADVANCED OPERATI ONS 6. Use to backspace (◄) over old name. 7. Use keypad to enter text for new name. This uses cellphone style text entry (press 2 several times for A). 8. When done, use select OK. 9. Use list. 4 10. Use 92 to to exit channel to exit scan list.
XG-100 ADVANCED OPERATI ONS Set or Remove Priority (PRI) Priority (PRI) channels are scanned more often than non-priority channels. The priority 1 channel is the channel that is currently selected using the channel knob on top of the radio. Custom scan configuration screens are shown here. Zone scan configuration is similar. 1. Enter Set up Scan. 2. Use scan list. 3. Use to select OPTIONS. 4. Use to highlight and select VIEW/EDIT. 5. Use channel. 6. Use to select OPTIONS.
XG-100 ADVANCED OPERATI ONS 7. Use to highlight and select SET PRI. Priority channel appears with a P2. Priority channel can also be set in the channel list. Scan list is shown here. 4 8. Use list. to exit channel 9. Use to exit scan list. 1. Enter Set up Scan. 2. Use to highlight custom scan list. 3. Use to select OPTIONS. 4. Use to highlight and select DELETE LIST. Delete Scan List You cannot delete zone scan lists.
XG-100 ADVANCED OPERATI ONS 5. Use list. to exit channel 6. Use to exit scan list. Set Active Scan List You can set custom scan list as active using the options menu. 1. Enter Set up Scan. 2. Use to highlight custom scan list. 3. Use to select OPTIONS. 4. Use to highlight and select SET ACTIVE. 4 Icon appears to left of active list. 5. Use list.
XG-100 ADVANCED OPERATI ONS 6. Use to exit scan list. 1. At main display, use for main menu. 2. Use to highlight and select MESSAGE or just press 8 . MESSAGE MENU 4 96 1 2 3 4 5 6 7 8 9 TUV 3. Observe messages in display. 4. Use to exit back to main screen.
XG-100 ADVANCED OPERATI ONS UTILITY MENU 1. At main display, use for main menu. 4 1 2 3 4 5 6 7 8 9 2. Use to highlight and select UTILITY or just press . 3. Use to highlight and select SELF TEST to run a series of internal radio tests. Status screen appears while testing followed by a screen with passed or failed results. 4. Use to view details.
XG-100 ADVANCED OPERATI ONS 5. Use to scroll through the test results. 6. Use 7. Use to highlight and select RADIO INFO to view radio information such as software and firmware revisions. 8. Observe radio information display. 9. Use to exit screen. 4 to exit screen. 10. Use to highlight and select BATTERY INFO.
XG-100 ADVANCED OPERATI ONS 11. Observe detailed information for the attached battery. 12. Use to exit screen. 4 13. Use screen.
XG-100 ADVANCED OPERATI ONS 4 This page intentionally left blank.
PROGRAMMING Section 5 Page Programming Via CPA . . . . . . . . . . . . . . .102 Edit Channel . . . . . . . . . . . . . . . . . . . . . . .
XG-100 PROGRAM M I NG This section provides information on front panel programming. Programming can also be accomplished by creating a plan using a computer. PROGRAMMING VIA CPA The Communications Planning Application (CPA) is to be used for the bulk of programming the XG-100P. Use USB cable, 10282-0410-A1. Using the CPA you can fully program the XP-100P, including the programmable button, switches and keys.
XG-100 PROGRAM M I NG 3. Additional settings can be found by scrolling down. 5 CAUTION: Only authorized users should attempt channel editing. If the active mission plan has been programmed to allow channel editing by a properly trained operator, you will be able to use the steps that follow. 4. Use CHAN. to select EDIT Password protection is automatically enabled by default when the mission plan is programmed to allow channel editing. 5. Enter the password programmed into the plan.
XG-100 PROGRAM M I NG 5 7. Use to highlight and select RX FREQUENCY. 8. Enter new receive frequency. 9. Use 10. Use DIGITAL CHANNEL SHOWN 104 to select OK. to cancel. 11. For digital channel, modify remaining channel settings: • TX FREQUENCY Transmit frequency. • TALKGROUP Talkgroup name cannot be set here. • RX NAC - Network Access Code (NAC) radio uses for selective squelch in receive.
XG-100 PROGRAM M I NG ANALOG CHANNEL SHOWN 12. For analog channel, modify remaining channel settings: • TX FREQUENCY Transmit frequency. • RX SQUELCH Squelch type radio uses in receive. • RX TONE - Tone radio uses to break selective squelch on receiving radio (Monitor and Squelch Types). • RX CODE - Code radio uses to break selective squelch on receiving radio (Monitor and Squelch Types). • TX SQUELCH Squelch type radio uses in transmit.
XG-100 PROGRAM M I NG DUAL CHANNEL SHOWN 5 106 13. For dual channel, modify remaining channel settings: • TX FREQUENCY Transmit frequency. • TALKGROUP Talkgroup name cannot be set here. • RX NAC - NAC radio uses for selective squelch in receive. • RX SQUELCH Squelch type radio uses in receive. • RXTONE - Tone radio uses to break selective squelch on receiving radio (Monitor and Squelch Types).
XG-100 PROGRAM M I NG • TXTONE - Tone radio transmits to break selective squelch on receiving radio (Monitor and Squelch Types). • TX CODE - Code radio transmits to break selective squelch on receiving radio (Monitor and Squelch Types). 5 Channels configured with TX SQUELCH type of CDCSS A or CDCSS B use RXCODE and TXCODE. Channels configured with TX SQUELCH type of CTCSS use RXTONE and TXTONE. 14. Use to exit menu. 15. Use to exit menu.
XG-100 PROGRAM M I NG PROGRAMMABLE HOT KEY AND BUTTONS The programmable hot key and buttons shown in XG-100P Controls are programmed using the CPA.
REFERENCE Section 7 Page Marine Frequencies . . . . . . . . . . . . . 110 Accessories . . . . . . . . . . . . . . . . . . .
XG-100 REFERENCE MARINE FREQUENCIES Refer to Table 2 for a list of maritime frequencies per United States Coast Guard (USCG), National Oceanic and Atmospheric Administration (NOAA), and Canadian Department Fisheries and Oceans, August 2009: • • • United States (US) International (Intl) Canada (CA) Table 2. Marine Frequencies Channel 7 Frequency Channel Usage US Intl CA 1 1 1a Shore (MHz) T: 156.05 R: 160.65 T: 160.65 R: 156.05 International: Public Correspondence, Port Operations T/R: 156.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl 5a 6 6 CA Shore (MHz) 5a T/R: 156.25 T/R: 156.25 US: Port Operations or VTS in Houston, New Orleans and Seattle areas. 6 T/R: 156.30 T/R: 156.30 US: Intership Safety International: Intership Canada: May be used for search and rescue communications between ships and aircraft. 7 7a Ship (MHz) T: 156.35 R: 160.95 T: 160.95 R: 156.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA Ship (MHz) Shore (MHz) 10 10 10 T/R: 156.50 T/R: 156.50 US: Commercial International: Intership, Port Operations Canada: Commercial - British Columbia coast area. May also be used for communications with aircraft engaged in coordinated search and rescue and antipollution operations. 11 11 11 T/R: 156.55 T/R: 156.55 US: Commercial. VTS in selected areas.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA 15 15 15 T/R: 156.75 T/R: 156.75 US: Environmental (Receive only). Used by Class C Emergency Position-Indicating Radio Beacons (EPIRBs). International: Intership, Port Operations Canada: Port operations and Ship Movement - British Columbia coast area. All operations limited to 1-watt maximum power. May also be used for on-board communications. 16 16 16 T/R: 156.80 T/R: 156.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA Ship (MHz) Shore (MHz) T: 156.95 R: 161.55* T: 161.55* R: 156.95 International: Public Correspondence, Port Operations 19a T/R: 156.95 T/R: 156.95 US: Commercial Canada: DFO/Canadian Coast Guard. Pacific Pilots - British Columbia coast area. 20 T: 157.00 R: 161.60 T: 161.60 R: 157.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA 23a Ship (MHz) Shore (MHz) T/R: 157.15 T/R: 157.15 US: US Coast Guard only 23b -- T/R: 161.75 Canada: Continuous Marine Broadcast (CMB) service. 24 24 24 T: 157.20 R: 161.80 T: 161.80 R: 157.20 US: Public Correspondence (Marine Operator) International: Public Correspondence, Port Operations 25 25 25 T: 157.25 R: 161.85 T: 161.85 R: 157.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl 61a CA Ship (MHz) Shore (MHz) 61a T/R: 156.075 T/R: 156.075 Canada: DFO/Canadian Coast Guard only in British Columbia coast area. T: 156.125 R: 160.725 T: 160.725 R: 156.125 International: Public Correspondence, Port Operations T/R: 156.125 T/R: 156.125 Canada: DFO/Canadian Coast Guard only in British Columbia coast area. T: 156.175 R: 160.775 T: 160.775 R: 156.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl 65a CA Ship (MHz) Shore (MHz) 65a T/R: 156.275 T/R: 156.275 US: Port Operations Canada: Search and rescue and antipollution operations on the Great Lakes. Towing on the Pacific Coast. Port operations only in the St. Lawrence River areas with 1 watt maximum power. Intership in inland Manitoba, Saskatchewan, and Alberta areas. 7 66 66a 66a T: 156.325 R: 160.925 T: 160.925 R: 156.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA Ship (MHz) Shore (MHz) 67 67 67 T/R: 156.375 T/R: 156.375 US: Commercial. Used for Bridgeto-bridge communications in lower Miss. River. Intership only. International: Intership, Port Operations Canada: May also be used for communications with aircraft engaged in coordinated search and rescue and antipollution operations.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA Ship (MHz) Shore (MHz) 72 72 72 T/R: 156.625 T/R: 156.625 US: Non-Commercial (Intership only) International: Intership Canada: May be used to communicate with aircraft and helicopters in predominantly maritime support operations. Pleasure craft - British Columbia coast area 73 73 73 T/R: 156.675 T/R: 156.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA Ship (MHz) Shore (MHz) 76 76 76 T/R: 156.825 T/R: 156.825 International: Port Operations Canada: Simplex port operation, ship movement and navigation related communication only. 1 watt maximum. 77 77 77 T/R: 156.875 T/R: 156.875 US: Port Operations (Intership only) International: Intership Canada: Pilotage - British Columbia coast area; 25 watts. Port operations only in the St.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl 81a CA Ship (MHz) Shore (MHz) 81a T/R: 157.075 T/R: 157.075 US: US Government only Environmental protection operations Canada: DFO/Canadian Coast Guard use only. T: 157.125 R: 161.725 T: 161.725 R: 157.125 International: Public Correspondence, Port Operations T/R: 157.125 T/R: 157.125 US: US. Government only Canada: DFO/Canadian Coast Guard use only. T: 157.175 R: 161.775 T: 161.775 R: 157.
XG-100 REFERENCE Table 2. Marine Frequencies (Continued) Channel Frequency Channel Usage US Intl CA Ship (MHz) Shore (MHz) T/R: 157.375 T/R: 157.375 US: Public Correspondence (Marine Operator) 87b T/R: 161.975 T/R: 161.975 Canada: Automatic Ship Identification and Surveillance System. 88 T: 157.425 R: 162.025 T: 162.025 R: 157.425 US: Commercial, Intership only. International: Port Operations Canada: Port operation and ship movement - British Columbia coast area. T/R: 157.425 T/R: 157.
XG-100 REFERENCE ACCESSORIES Only use Harris approved accessories. Contact Harris for requirements not contained in this list: Standard Remote Speaker Microphone (RSM) - Rugged, submersible, 6 ft. (stretch length) coil cord, swivel clip, 3.
XG-100 REFERENCE 7 This page intentionally left blank.
GLOSSARY G
XG-100 GLOSSARY -AAES AES-256 AMBE+2 ANSI Advanced Encryption Standard Advanced Encryption Standard, 256-bit Advanced Multi-Band Excitation implementation 2 American National Standards Institute -B- -C- G C CA CDCSS CH INFO CKR CMB CPA CTCSS Celsius Canada Continuous Digital Coded Squelch System Channel Information Common Key References Continuous Marine Broadcast Communications Planning Application Continuous Tone Coded Squelch System -D- DES DES-OFB DFO Digital Encryption Standard Digital Encrypti
XG-100 GLOSSARY -IID IEEE INTL Identification Institute of Electrical & Electronics Engineers International -J-K- kHz KID KVL kilo (103) Hertz Key Identification Key Variable Loader (Motorola KVL 3000 Plus) -L- LAT/LONG DMS LED Li-ION Latitude/Longitude Degrees Minutes Seconds Light Emitting Diode Lithium-ION -M- MHz mm ms Megahertz Millimeter milli (10-3) seconds -N- NAC Ni-MH NOAA Network Access Code Nickel Metal Hydride National Oceanic and Atmospheric Administration -O- OET Office of Enginee
XG-100 GLOSSARY -RRSM RX Remote Speaker Microphone Receive -S- SMA Subminiature version A -T- TIA TX Telecommunications Industry Association Transmit -U- G UHF US USCG UTC UTM Ultra High Frequency United States United States Coast Guard Universal Time Coordinated Universal Transverse Mercator -V- VDC VHF VTS Volts, Direct Current Very High Frequency Vessel Traffic Service -W- WEEE Waste from Electric and Electronic Equipment -X-Y-Z- 128
XG-100 I NDEX Symbols 1 Channel, Priority ...................... 91 3000 Plus, Create Key in the KVL . 46 3000 Plus, Create Keygroup in the KVL ................................ 47 3000 Plus, Zeroize All from KVL ... 57 3000 Plus, Zeroize Keygroups Using KVL ............................ 55 3000 Plus, Zeroize Keys Using KVL ..................................... 53 CH INFO Menu ...........................60 Channel Bank, Select ..................24 Channel Using Knob, Select .........24 Channel, Edit ......
XG-100 INDEX H M Hot Key and Buttons, Programmable .......................108 Main Display ...............................21 Make a Priority Call .....................30 Make an Individual Call ................28 Marine Frequencies .....................110 Menu Navigation .........................22 Menu, CH INFO ..........................60 Menu, Message ..........................96 Menu, Settings ............................62 Menu, Shortcut ...........................78 Menu, Utility .................
XG-100 I NDEX Plus, Zeroize Keys Using KVL 3000 .................................... 53 Power On and Set Volume ........... 23 Priority (PRI), Set or Remove ....... 93 Priority 1 Channel ....................... 91 Priority Call, Make a .................... 30 Programmable Hot Key and Buttons ................................ 108 Programming ............................. 101 Programming Via CPA ................ 102 R Radio, Assemble the ................... 14 Radio, Zeroize All from ................
XG-100 INDEX vs Custom Scan, Zone Scan .........86 X XG-100P Controls .......................18 Z Zeroize All from KVL 3000 Plus .....57 Zeroize All from Radio .................52 Zeroize Keygroups Using KVL 3000 Plus ..............................55 Zeroize Keys Using KVL 3000 Plus 53 Zone Scan vs Custom Scan .........86 Zone Using Menus, Select ............
R a. Harris Corporation, a Delaware Corporation, through its RF Communications Division (hereinafter "Seller") warrants to the original purchaser for use (hereinafter "Buyer") that Equipment manufactured by or for the Seller shall be free from defects in material and workmanship, and shall conform to its published specifications. With respect to all non-Seller Equipment, Seller gives no warranty, and only the warranty, if any, given by the manufacturer shall apply.
installed, used, maintained or repaired, or, (v) has been subjected to any other kind of misuse or detrimental exposure, or has been involved in an accident. e. The preceding paragraphs set forth the exclusive remedies for claims based upon defects in or nonconformity of the Equipment, whether the claim is in contract, warranty, tort (including negligence), strict liability or otherwise, and however instituted. Upon the expiration of the warranty period, all such liability shall terminate.
RF Communications Division │ 1680 University Ave │ Rochester, NY USA 14610 Tel: 585-244-5830. Fax: 585-242-4755 www.harris.