Installation & Assembly

FAD
&
SAME
THESE
Nh
H
KU
INSTALLATION
OPERATION
INSTRUCTIONS
TOOLS
&
MATERIALS
REQUIRED
o
Blade
screw
driver
Adjustable
wrenen
»
Step Ladder
e
Wire
cutters
Wiring
supplies as required by
electrical
code
CAUTION:
Before
assembling your
lighting
fixture,
refer to the
section
titled
ELECTRICAL
CONNECTIONS.
If
you
feel
you
do
not
have
electrical
wiring
experience, refer to a do-it-yourself
wiring
handbook or
have
your fixture installed by a qualified
licensed
electrician.
GENERAL
1.
To
ensure
the
success
of
the
installation,
be
sure
to read
these
instructions and
review
the diagrams thoroughly before begin-
ning.
2.
All
electrical connections
must
be in accordance with
local
codes, ordinances, or the
National
Electrical
Code.
If
you
are
unfamiliar
with
methods
of
installing
electrical
wiring,
secure
the services
of
a
qualified
licensed electrician.
3.
These
fixtures are intended
to
be mounted
to
a
4"X2y8"
deep
metal octagon outlet
box.
The
box
must
be
directly
supported by
the
building
structure.
4.
Before
starting the
installation,
disconnect the power
by
taming
off
the
circuit
breaker or
by
removing
the fuse at the
fuse
box.
Turning
the power
off
using
the light
switch
is
not
sufficient
to
prevent
electrical
shock.
NOTE:
The important
safeguards
and instructions appearing in
this manual are not
meant
to cover
all
possible conditions and
situations
that
may occur.
It
must
be understood
that
common
sense,
caution and
care
are factors
which
cannot
be built into any
product.These
factors
must
be
supplied
by
theperson(s)caring
for
and
operating
the
fixture.
UNPACK THE
FIXTURE
Check
the
contents
of
the
box.
You
should
receive:
8
Mounting
hardware
package
«
Lampholder assembly(s)
Mounting
bracket
Shade(s)-not
provided
on
all
models
Shade
attachment
screws (3 for each
shade)-not
provided on
all
models
PREPARE
THE
FIXTURE
NOTE:
FIRST
TURN
OFF
ELECTRICITY
ADJUST
THE
CROSSBAR
1.
If
you
are
replacing
an existing
fixture,
disconnect and remove
the
old
fixture.
Expose the supply
wiring
from
the outlet
box.
2.
Some
fixtures
are
provided
with
a
threaded
nipple
(see
Fig.
1)
or
machine screws (see
Fig.
2 and
2A)
for
attaching the
fixture
to
the mounting
bracket.If
your
fixture
is
supplied
with
a
threaded
nipple,
screw
the
nipple
3
complete
turns
into the mounting
bracket
and
lock
into place
with
a hexagon
lock
nut. If
your
fixture
is supplied
with
machine screws,
thread
the machine
screws into the opposite
side
of
the mounting bracket
from
the
green ground
screw.
Lock
the machine screws into place with
locknuts.
EXCEPTION:
Ceiling
mounted fixtures
with
keyhole
slots
should
have
machine screws entering mounting bracket
from
same
side as green grounding screw (see
Fig,
2
A)
3.
Fasten the mounting bracket to the outlet box using the two
screws
supplied
with
the outlet
box.If
your
Fixture
is
supplied
with
a channel
shape
mounting bracket
with
keyhole slots for
attachment
to
the mounting surface
(see
Fig.3).
it
will
be
necessary
to mark the location
of
the keyhole slots on the
mounting surface and
drill
holes
for
fasteners
(not provided)
Use
fasteners
suitable
for
the mounting surface. The narrow
end
of
the
keyhole
slot should
face
up.
4.
Attach
grounding wire(green or
bare
copper)
from
the supply
circuit
to the mounting bracket with the green grounding
attachment
screw
provided.Some
models
have
a grounding
wire
attached
to the fixture
for
models
that
employ a green or
bare
copper grounding
wire,
it
will
be
necessary
to connect the
green
or
bare
grounding
wire
to
the grounding conductor
of
the supply
circuit.
Attach all grounding conductors to the
moimting
bracket
with
the green grounding
attachment
screw.
5.
Make
electrical
connections-SEE
BELOW.
ELECTRICAL
CONNECTIONS
To
make
electrical
connections:
Connect the
white
wire
(s)
from
the
fixture
to the white
wire
of
the
supply
circuit.
Connect the
black
wire
(s)
from
the fixture to the
black
wire
of
the supply
circuit.
Connect
me
green (or
bare
copper)
colored
wire
to the grounding conductor
of
the supply
circuit.
If
your
fixture
is
supplied
with
an
SPT
Cord
connect the
half
of
the
SPT
Cord
that
is
ribbed surface
to
the white
wire
of the supply
circuit.
Connect the smooth
half
of
the wire (the
half
with
mark-
ings) to the black
wire
of the supply
circuit.
Use
UL.
Listed
wire
connectors suitable
for
the
size,
type, and number
of
conductors.
No
loose
strands
or loose wires should be
present.
Secure wire
connectors
with
U.L.
listed
electrical
tape.
FINAL
ASSEMBLY
1.
Spread the
electrical
splices so
that
the black wires are on one
side
of
the outlet box and the white wires are on the
other
side
2.
Place
fixture
against
mounting surface
allowing
the
threaded
nipple
or machine screws to
pass
through the coverplate.Secure
with
mounting
nut
or acorn
nuts.
For
fixtures with channel
shape
mounting bracket.
Place
the coverplate over the channel
and
secure
with
screws
provided
3.
If
applicable place candle cover(s) over lampholder(s) before
installing
bulb (s). Install the
lighfbulb(s)
(not provided).
CAUTION:
Refer to the
relampirig
label located
near
the
lampholder
for
recommended maximum
wattage-do
not
exceed recommended
wattage.
4.
If
applicable,attach
shades
to
fixture
some
shades
require the
use
of
shade
attachment
screws
.
Do not overtighten
these
screws-too
much
pressure
could
cause
glass
breakage.See
Fig.
3
for
placement
of
fabric
spacer,
not supplied on
all
models.
5. Outdoor
wall
fixtures
must
be caulked
with
suitable
RTV
or
Silicone
compound around the top and sides of the coverplate to
reduce
the
chance
of water intruding into
the
splicing
area.
Leave
the bottom clear to
allow
moisture a
means
of
escape.
6. Restore
electricity
and check the operation
of
your
new lighting
fixture.
Printed
in
China

Summary of content (2 pages)