M2000 Facial Recognition Terminal User Manual Original operating instructions Version 1.
General Notice Although every care has been taken to ensure that this manual is reliable and accurate, Hanvon Corporation (here after referred to as Hanvon) provides it „as is‟ and without express, implied, or limited warranty of any kind. In no event shall Hanvon be liable for any loss or damage caused by the use of this manual. This manual describes M2000 facial recognition terminal in detail and contains full operating instructions.
Content 1. About this document ....................................................... 4 2. Product Features ............................................................. 5 2.1 Appearance View ............................................................... 5 2.2 Installation Guide ............................................................... 7 2.3 Connection Port ................................................................. 8 2.4 Power up terminal ......................................................
0. About this document Validity These instructions are valid for the M2000 Facial Recognition Terminal. Target group The target group for this document comprises the terminal operator and technical personnel. Content and purpose These user manual describe the M2000 facial recognition terminal installation and operation information to users. Supplementary documents N/A Abbreviations Hanvon Face ID M2000 Hanwang Technology Co., Ltd Brand Hanwang Technology Co.
1. Product Features 2.1 Appearance View 1. 2. 3. 4. 5. 6. Fingerprint Reader Display Button: Previous or next field Button: Main function menu Button: Backspace and delete Button: Digital Keypad 7. Button: Cancel button 8. Button: Confirm button 9. Camera 10. Loudspeaker 11. Power Adaptor Port 12. Network Cable Port 13.
Confidential 14. USB Socket(Just for data transmission) 15.
2.2 Installation Guide User can drill the holes according to the mounting diagram. Use the 4 wall mount, screws to mount the bracket to the wall. User also could mount the terminal by choosing your “shortest” users and have them stand in front of the device. Hold the terminal on the wall that employee can comfortably center their face in the LCD display window. Use the 2 bracket screws on the bottom of the bracket.
2.3 Connection Port PIN J1.1 J1.2 J1.3 J1.4 J1.5 J1.6 J1.7 J1.8 J1.9 J1.10 PIN J2.1 J2.2 J2.3 J2.4 J2.5 J2.6 PIN J3.1 J3.2 J3.3 J3.4 J3.
2.4 Power up terminal Select a proper language when the terminal boot first time.
2. Operating Guide 3.1 Admin. Management Admin. Management Main Menu If no admin. in system, then press
Admin. Types Super Admin. can operate all functions and normal administrators. The first administrator must be super admin and can‟t be deleted in system. Normal Admin. can operate User/Data/USB Management function, check system info. and auto test function. Verification modes: ID and Pin: Use ID and password sequentially as a verification method. ID and Face: Use ID and face sequentially as a verification method. Card and Face: Use card and face sequentially as a verification method.
User Photo: Press [OK] to capture a photo for the user. If don‟t, please check [ESC]. Admin Verification After set an admin. account, then press
to activate admin verification process. Input admin. ID (or using registered RFID card) Input corresponding password or using face verification, according to the mode during admin registration, after verification is successful, then the system enter to the main menu. Modify & Delete Admin account Select a registered admin.3.2 User Management User Management Main Menu User Enroll Input User ID The range of User ID is from 1-99,999,999,999,999. Input name Press to
will switch character inputing mode between and . User Name can contain 18-bit characters totally. Select a verification mode Face: Use face as a verification method. Select a privilege Access & Attendance: The terminal is used for access control and time attendance with relay output. Attendance: The terminal is only used for time attendance without relay output. User Photo: Press [OK] to capture a photo for the user. If don‟t, please check [ESC]. User registering finished. Input User ID Modify User Following the procedure to change and .
Delete All Users Press [OK] (or [ESC]) to confirm (or cancel) this process. All user‟s ID, name and templates will be erased. This step is irreversible. Not affect Admin data and records. User List Confidential Enter user list to check Un-enrolled and Enrolled list. Press [OK] (or [ESC]) to confirm (or cancel) this process.
3. 3 Data Management Data Management Main Menu Record Management Record Inquiry: User records can be inquiry by User ID/Name. Select a search mode to inquiry user records. Select inquiry duration: 1 day/6 days /All records / from start date to end. Confidential Del. by 6 months Before 6 months records will be erased. This step is irreversible. Backup all user data before doing this step.
Del. by Date: Input the delete time. Delete All Records All records will be erased. This step is irreversible. Backup all user data before doing this step. Security Photo Security Photo Switch: Turn on / off security photos function. Default switch is off. Security Photo Browser Switch: User can input the date to browser the security photo. Delete All All security photos will be erased. This step is irreversible. Backup all user data before doing this step.
3.4 USB Management USB Management Main Menu Don‟t remove USB Disk while data transferring. Try other USB Disk, if the terminal doesn‟t recognize it. Export Management Exp. Admin.: Export all admin. data into a file which named as “MANAGER.TXT ” Exp. Part Users: Export part user‟s data into a file which named “USER.TXT” Exp. All Users: Export data of all users. Data is stored into a “USERALL.TXT” file. Exp. All Records: Export all user records into a file, which named as “TIME+SN”.TXT.
Exp. Admin. Log: Export all admin operating logs. Data is stored into a “LOG.TXT” file. Exp. Security photos: Set a time duration of exporting security photos Security photos are saved in folder Exp. Config. File: Export terminal configuration file into a file, which named as “sys.dat”. Import Management Import admin Import all administrators data from MANAGER.TXT file on an USB Disk into the terminal. Import Part Users Import all users data from USER.
The contents of WORKCODE.TXT file are list of + + . The range of work code ID is from 1-99,999,999. Import work status Import all work status data from WORKSTATUS.TXT file on a USB Disk into the terminal. The contents of STATUS.TXT file are list of + + . The range of work status ID is from 1-255. Import Config. File Import terminal configuration file from sys.dat file on a USB Disk into the terminal.
3.5 System Settings System Main Menu Basic Date and Time Date and Time: System date and time can be set with this function. Date Format: System date format can be set in 9 formats. Daylight Saving: Set daylight saving time. Select proper DST format according to DST rule of your region. Month-Day-Hour: DST time starts on 01:00 AM May. 1st, and ends at 03:00 AM Oct. 2nd Default is off.
Volume Set Volume: terminal support 4 modes to customers. The default is medium. Head Photo Switch Photo ID Switch Switch On: Users head photo will display on the screen when the user verified successful. Switch Off: Users head photo will not display on the screen when user verified successful. Communication Confidential Communication: Network and Wiegand setting.
1. Network -Push to sever Push to sever Switch: On/OFF The default is off. 2. Record Data Switch: User can select record data/record+security photo data be pushed to the server. 3. User Data Switch: User can select user template data/user template+head photo data be pushed to the server. 4. Server configuration: User needs to set IP address and port of server. The default IP address is 192.168.0.3. The default CMD/HBP 9920/9924. The default HBP Delay is 60.
Communication -Wiegand Output Wiegand Output-Type: System supports standard Wiegand protocol output on the follow list. The default type is Wiegand output 26. Wiegand Output-Pulse Width Set proper pulse width for wiegand output to match the external wiegand input terminal. The default Pulse Width is 100 us. The pulse width range is 20~8000 us. Wiegand Output-Pulse Interval Set proper pulse interval for wiegand output to match the external wiegand input terminal.
Attendance – Bell Bell: User can select the attendance bell on the list. System supports 24 bell groups. Bell Status Switch. The default is off. Edit Bell Time: User can set bell time on/off from Monday to Sunday. The default is 1-1-1-1-1-1-1, (1=On, 0=Off) Bell Audio: System supports 7 groups audio. Attendance – Work Status Work Status: It is defined to mark the work status related to each record such as in, out, overtime in, overtime out. The default is off.
Auto Switch: It is defined to display the work status automatically according to the time that set. For example, if the time of work status “in” set as 9:00 and work status “out” set as 18:00, the work status “in” will be displayed automatically when time reach 9:00 till time reach 18:00, the work status “out” will be displayed automatically when time reach 18:00 till time reach 9:00 in next day. The default is off. Switch Time: User can set auto switch time.
Add: User can browse/add work code on this list. Edit and Delete: User edit the work status and code with ID/Name. Security Security – Access Control Unlock: User can set duration time of unlock. The default duration is 3 seconds. The duration range is 0~10 seconds. Unlock Sync: It is defined to enable the unlock execution synchronic to the attendance interval. The unlock execution will be only executed at the first time for the same user during defined time of attendance interval time.
Sensor: User can set sensor type with None/NO/NC The default sensor is “None”. User can set detection delay time. The default duration is 10 seconds. The duration range is 1~99 seconds. Security – Alarm Sensor Alarm Switch: Enable/Disable sensor alarm function. The default is OFF. Rejection Alarm Switch: Enable/Disable rejection alarm function The default is OFF. Rejection Times: Set the rejection times to activate rejection alarm The default duration is 3 times.
Advanced Relay 2 Output: User can set output to external Bell or Alarm output. Duplication Check: System will match new enrolled user with database to check this user already enrolled or not. If system displaying “Similar to ID XX”, admin is suggested to check this user for double enrollment. The default is OFF. Face Detection Switch: Enable/Disable face detecting function when using Card and Photo recognition method. The default detection is off. Algorithm Version: User can select V2.6 or V3.
3.6 System Info. Capacity Info. Face: Current enrolled user numbers and total capacity of user numbers for face related recognition mode. Other: Current enrolled user numbers and total capacity of user numbers for card and ID+PIN related recognition mode. Record: Current record numbers and total capacity of record numbers. S. Photo: Current security photo numbers and total capacity of security photos. Unsent Records: Unsent record numbers while push to server mode is on.
3. 7 Auto Test Test All: Test all below hardware automatically Press if it is working normal Press if it is working abnormal. A list of status will be displayed after all testing. Confidential Check LCD: Display Red, Green and Blue on the screen Check Keyboard: Follow the screen message to check all keys. Check Detection. Check Speaker.
Confidential Check Camera. Check RFID Cards. Check Network. Check USB Port.
3. Appendix Appendix1.
Appendix2. Caution Installation Environment Terminal should install inside of the room, and make sure the installation place far with the window/door/light more than 2 meters. Outside of the room Sunlight directly shines on the terminal through the window. Sunlight slanted shines on the terminal through the window. Restoration and restart When the system halted and cannot quit, you can remove the adapter to restore and restart the system, or you also can press to restart the terminal.
Please prevent the screen from oil or any sharp objects. Please use the equipped adapter for the terminal, the other unknown adapters will burn out the terminal. Warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the user‟s authority to operate the equipment. This device complies with part 15 of the FCC Rules.