FT200 Facial Recognition Terminal User Manual Original operating instructions Version 1.
General Notice Although every care has been taken to ensure that this manual is reliable and accurate, Hanvon Corporation (here after referred to as Hanvon) provides it ‘as is’ and without express, implied, or limited warranty of any kind. In no event shall Hanvon be liable for any loss or damage caused by the use of this manual. This manual describes FT200 facial recognition terminal in detail and contains full operating instructions.
Content 0. About this document ...................................................................... 4 1. Product Features ............................................................................ 5 2.1 Appearance View ............................................................................. 5 2.2 Installation Guide ............................................................................. 6 2.3 Connection Port ............................................................................... 7 2.
0. About this document Validity These instructions are valid for the FT200 Facial Recognition Terminal. Target group The target group for this document comprises the terminal operator and technical personnel. Content and purpose These user manual describe the FT200 facial recognition terminal installation and operation information to users. Supplementary documents N/A Abbreviations Hanvon Face ID FT200 Hanwang Technology Co., Ltd Brand Hanwang Technology Co.
1. Product Features 2.1 Appearance View Confidential 1. Touch Display 2. Camera 3. RFID Reader 4. USB Socket 5. Reset Button 6. Mini-USB Socket(Not open) 7. Cooling Hole 8. Power Adaptor 9. Installation Port 10. Connection Port 11.
2.2 Installation Guide User can drill the holes according to the mounting diagram. Use the 4 wall mount, screws to mount the bracket to the wall. User also could mount the terminal by choosing your “shortest” users and have them stand in front of the device. Hold the terminal on the wall that employee can comfortably center their face in the display window. Use the 2 bracket screws on the bottom of the bracket.
2.3 Connection Port Top→Below PIN J1.1 J1.2 J1.3 J1.4 J1.5 PIN J2.1 J2.2 J2.3 J2.4 Definition VC12V GND LOCK_NO LOCK_COM LOCK_NC Definition WGD0_OUT WGD1_OUT ALARM_COM ALARM _NO Feature 12V Power Supply Ground Door Lock Feature Weigand Output Alarm Set 2.4 Power up terminal Select a proper language when the terminal boot first time.
2. Operating Guide 3.1 Admin. Management ¾ Admin. Management Main Menu z If no admin. in system, then press
¾ Admin. Types z Super Admin. can operate all functions and normal administrators. The first administrator must be super admin and can’t be deleted in system. z Normal Admin. can operate User/Data/USB Management function, check system info. and auto test function. Verification modes: ID and Pin: Use ID and password sequentially as a verification method. ID and Face: Use ID and face sequentially as a verification method. Card and Face: Use card and face sequentially as a verification method.
z ¾ User Photo: Press [Capture] to capture a photo for the user. If don’t, please press [Cancel]. Admin Verification z After set an admin. account, then press
to activate admin verification process. z Input admin. ID (or using registered RFID card) z Input corresponding password or using face verification, according to the mode during admin registration, after verification is successful, then the system enter to the main menu. ¾ Modify & Delete Admin account z Select a registered admin.3.2 User Management ¾ User Management Main Menu ¾ User Enroll z Input User ID The range of User ID is from 1-99,999,999,999,999. z Input name Press will switch character inputing mode between and . User Name can contain 18-bit characters totally. z Select a verification mode Face: Use face as a verification method. Card and Face: Use card and face sequentially as a verification method. Card or Face: Use card or face separately as a verification method.
z User Photo: Press [Capture] to capture a photo for the user. If don’t, please press [Cancel]. z User registering finished. z Input User ID ¾ Modify User z Following the procedure to change and . , ¾ Delete User z Input an User ID z Press [Confirm] (or [Cancel]) to confirm (or cancel) this process. ¾ Delete All Users z Press [Confirm] (or [Cancel]) to confirm (or cancel) this process. All user’s ID, name and templates will be erased.
¾ User List z Enter user list to check Un-enrolled and Enrolled list. z Press [Confirm] (or [Cancel]) to confirm (or cancel) this process.
3. 3 Data Management ¾ Data Management Main Menu ¾ Record Management z Record Inquiry: User records can be inquiry by User ID/Name. z Confidential Select a search mode to inquiry user records. z Select inquiry duration: 1 day/6 days /All records / from start date to end. z Del. by 6 months Before 6 months records will be erased. This step is irreversible. Backup all user data before doing this step.
z Del. by Date: Input the delete time. z Delete All Records All records will be erased. This step is irreversible. Backup all user data before doing this step. ¾ Security Photo z Security Photo Switch: Turn on / off security photos function. Default switch is off. z Delete All All security photos will be erased. This step is irreversible. Backup all user data before doing this step.
3.4 USB Management ¾ USB Management Main Menu Don’t remove USB Disk while data transferring. Try other USB Disk, if the terminal doesn’t recognize it. ¾ Export Management z Exp. Admin.: Export all admin. data into a file which named as “MANAGER.TXT ” z Exp. Part Users: Export part user’s data into a file which named “USER.TXT” z Exp. All Users: Export data of all users. Data is stored into a “USERALL.TXT” file. z Exp. All Records: Export all user records into a file, which named as “TIME+SN”.TXT.
Import all ID and name information of users from USERLIST.TXT file on an USB Disk into the terminal. It is a shortcut way to add user ID and name for a terminal before registration process. The contents of USERLIST.TXT file are list of + + . The range of user ID is from 1-99,999,999,999,999. z Import work code Import all work code data from WORKCODE.TXT file on a USB Disk into the terminal. The contents of WORKCODE.TXT file are list of + + .
¾ Firmware Upgrade z Confidential Upgrade a new firmware for a terminal. Firmware files are and
3.5 System Settings ¾ System Main Menu ¾ Basic ¾ Date and Time z Date and Time: System date and time can be set with this function. z Date Format: System date format can be set in 9 formats. z Daylight Saving: Set daylight saving time. Select proper DST format according to DST rule of your region. Month-Day-Hour: DST time starts on 01:00 AM May. 1st, and ends at 03:00 AM Oct. 2nd Default is off.
¾ Volume z Set Volume: terminal support 4 modes to customers. The default is medium. ¾ Head Photo Switch z Photo ID Switch Switch On: Users head photo will display on the screen when the user verified successful. Switch Off: Users head photo will not display on the screen when user verified successful. ¾ Communication z ¾ Communication: Network and Wiegand Output setting.
If the DHCP function turned off, user needs configure the IP Address/Mark/Gate for terminal. z Network -Password It is for enhancing the security of network access through software or SDK. The password can be set max 8 bits. z 1. Network -Push to sever (Optional) Push to sever Switch: On/OFF The default is off. 2. Record Data Switch: User can select record data/record+security photo data be pushed to the server. 3.
4. Server configuration: User needs to set IP address and port of server. The default IP address is 192.168.0.3. The default CMD/HBP port is 9920/9924. The default HBP Delay is 60. The port parameters have to more than 1024. The HBP delay range is 10~300. ¾ Communication -Wiegand Output z z Wiegand Output-Type: System supports standard Wiegand protocol output on the follow list. The default type is Wiegand output 26.
z Wiegand Output-Content user can set Weigand output content with Card ID or User ID. The ¾ Attendance ¾ Attendance -Interval z Interval: Only the first record will be saved while several records created by same user during defined interval time. The default Interval is 1 minute. the The interval range is 0~255 minutes. ¾ Attendance – Bell z Bell: User can select the attendance bell on the list. System supports 24 bell groups. Confidential z Bell Status Switch. The default is off.
z ¾ Bell Audio: System supports 7 groups audio. Attendance – Work Status z Work Status: It is defined to mark the work status related to each record such as in, out, overtime in, overtime out. The default is off. If Work Status is on, user could select the desired work status directly . z Auto Switch: It is defined to display the work status automatically according to the time that set.
z Edit and Delete: Add User could edit the ID and Name of work status. The default work status is In/Out and they can’t be deleted. New added work status could be deleted. ¾ Attendance – Work Code z Work Code: It is defined to mark the work code related to each record such as engineering, maintaining, training etc. The default is off. If Work Code is on, user has to select the desired work code after verification. z z Add: User can browse/add work code on this list.
¾ Security – Access Control z Unlock: User can set duration time of unlock. The default duration is 3 seconds. The duration seconds. range is 0~10 z Unlock Sync: It is defined to enable the unlock execution synchronic to the attendance interval. The unlock execution will be only executed at the first time for the same user during defined time of attendance interval time. The default is off. ¾ Security – Alarm z Rejection Alarm Switch: Enable/Disable rejection alarm function The default is OFF.
z Relay 2 Output: User can set output to external Bell or Alarm output. z Duplication Check: System will match new enrolled user with database to check this user already enrolled or not. If system displaying “Similar to ID XX”, admin is suggested to check this user for double enrollment. The default is OFF. z Test All: Test all below hardware automatically Press if it is working normal Press if it is working abnormal. A list of status will be displayed after all testing.
3.6 System Info. ¾ System Info. ¾ Capacity Info z Face: Current enrolled user numbers and total capacity of user numbers for face related recognition mode. z Other: Current enrolled user numbers and total capacity of user numbers for card and ID+PIN related recognition mode. z Record: Current record numbers and total capacity of record numbers. z S. Photo: Current security photo numbers and total capacity of security photos. z Unsent Records: Unsent record numbers while push to server mode is on.
3. Appendix Appendix1. Product Specification z User capacity 500 users for face related verification method; 500 users for other verification methods including card, card and photo, ID and Pin z Record capacity Data Capacity:100,000 Security Photo: 7,000 z Verification methods Face Card and Face Card or Face Card ID and Pin z Languages: English Spanish Portuguese Turkish z Recognition algorithm V3.1 z z z Display: 2.
Appendix2. Caution z Installation Environment Terminal should install inside of the room, and make sure the installation place far with the window/door/light more than 2 meters. Outside of the room z Sunlight directly shines on the terminal through the window. Sunlight slanted shines on the terminal through the window. Restoration and restart When the system halted and cannot quit, you can remove the adapter to restore and restart the system, or you also can press to restart the terminal.
Please prevent the screen from oil or any sharp objects. Please use the equipped adapter for the terminal, the other unknown adapters will burn out th t i l Warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules.
—Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.