FA600 Series Facial Recognition Terminal User Manual Original operating instructions Version 1.
General Notice Although every care has been taken to ensure that this manual is reliable and accurate, Hanvon Corporation (here after referred to as Hanvon) provides it „as is‟ and without express, implied, or limited warranty of any kind. In no event shall Hanvon be liable for any loss or damage caused by the use of this manual. This manual describes FA600 facial recognition terminal in detail and contains full operating instructions.
Content 1. About this document ....................................................... 4 2. Product Features ............................................................. 5 2.1 Appearance View .............................................................. 5 2.2 Installation Guide .............................................................. 6 2.3 Connection Port ................................................................ 7 2.4 Power up terminal .........................................................
1. About this document Validity These instructions are valid for the FA600 Facial Recognition Terminal. Target group The target group for this document comprises the terminal operator and technical personnel. Content and purpose These user manual describe the FA600 facial recognition terminal installation and operation information to users. Supplementary documents N/A Abbreviations Hanvon Face ID FA600 Hanwang Technology Co., Ltd Brand Hanwang Technology Co.
2. Product Features 2.1 Appearance View 1. 2. LED lights Keypad 3. LCD screen 4. Dual Sensor Cameras 5. RFID area key: backplace 6. Speaker key: enter to main menu 7. Mini USB port: factory debugging use key: move to previous or next field key: process Confidential port(Just for data transmission) confirm current 9. Reset port 10. Mounting holes process key: 8. USB 11. Tamper alarm trigger cancel current 12. Terminal blocks 13.
2.2 Installation Guide User can drill the holes according to the mounting diagram. Use the 3 wall mount, screws to mount the bracket to the wall. Use the 1 bracket screws on the bottom of the bracket. Be careful not to pinch the AC cord. When finished, plug the Power Adapter into the AC wall outlet.
User also could mount the terminal by choosing your “shortest” users and have them stand in front of the device. Hold the terminal on the wall that employee can comfortably center their face in the LCD display window. 2.3 Connection Port 12V DC-OUT RJ45-2 J1 LOCK-NO GND LOCK-NC ALARM+ RJ45-3 RJ45-1 GND RJ45-6 J3 P4 P1 P1 P5 J2 P1 485B P1 P2 PIN J1.1 J1.2 J1.3 J1.4 PIN J2.1 J2.2 J2.3 J2.4 J2.5 PIN J3.1 J3.2 J3.
J3.4 J3.5 J3.6 J3.9 J3.8 J3.9 J3.10 PIN J4.1 J4.2 PIN J5.1 J5.2 J5.3 J5.4 J5.5 J5.6 LOCK-COM LOCK-NC DOOR SENSOR GND EXIT BUTTON ALARM+ ALARMDefinition GND 12V DC Definition WGin-D0 WGin-D1 GND RLED GLED BEEP Magnetic Sensor Ground Door Switch Alarm/Bell Output (Relay2) Feature Ground 12V Power Supply (Input) Feature Wiegand Input Ground Red LED Green LED Buzzer 2.4 Power up terminal Select a proper language when the terminal boot first time.
3. Operating Guide 3.1 Admin. Management Admin. Management Main Menu If no admin. in system, then press
Input Admin. Name: Press
to switch character inputting mode between , and . Admin. Types Super Admin. can operate all functions and normal administrators. The first administrator must be super admin and can‟t be deleted in system. Normal Admin. can operate User/Data/USB Management function, check system info. and auto test function. Verification modes: ID and Pin: Use ID and password sequentially as a verification method. Admin Verification After set an admin. account, then press
to activate admin verification process. Input admin. ID (or using registered RFID card) Input corresponding password or using face verification, according to the mode during admin registration, after verification is successful, then the system enter to the main menu. Modify & Delete Admin account Select a registered admin. account to modify or delete this account. Modify admin. User Enroll Input User ID The range of User ID is from 1-99,999,999,999,999. Input name Press to
will switch character inputing mode between and . User Name can contain 18-bit characters totally. Select a verification mode Face: Use face as a verification method. Card and Face: Use card and face sequentially as a verification method. Card or Face: Use card or face separately as a verification method. Card: Use card as a verification method. Modify User Input User ID Following the procedure to change user name, and . Timezone Type includes Group Timezone and User Timezone Select a group number for this user Use function to create group first.
Select 3 timezones for this user Each user can set 3 user timezones. Use function to create group first. Delete User Input an User ID Press [OK] (or [ESC]) to confirm (or cancel) this process. Press [OK] (or [ESC]) to confirm (or cancel) this process. Delete All Users All user‟s ID, name and templates will be erased. This step is irreversible. Not affect Admin data and records. User List Enter user list to check Un-enrolled and Enrolled list.
3. 3 Data Management Data Management Main Menu Records Inquiry Record Inquiry: User records can be inquiry by User ID/Name. Confidential Select a search mode to inquiry user records.
Delete 6 Months Records Del. by 6 months Before 6 months records will be erased. This step is irreversible. Backup all user data before doing this step. Delete Records by Date Del. by Date: Delete all records before indicated date (including this day) . All records will be erased. This step is irreversible. Backup all user data before doing this step. Delete All Records Delete All Records Before 6 months records will be erased. This step is irreversible.
3.4 USB Management USB Management Main Menu Don‟t remove USB Disk while data transferring. Try other USB Disk, if the terminal doesn‟t recognize it. Export Management Export Admin Expt. Admin.: Export all admin. data into a file which named as file. Export Part Users Expt. Part Users: Export part user‟s data into a file which named Confidential file. Continue to input User ID to add them into the export list.
Export All Users Expt. All Users: Export data of all users. Data is stored into a file. Export All Records Expt. All Records: Export all user records into a file, which named as “TIME+SN.TXT”. For example, , “095” is the last 3 bits of SN of the terminal. Export Admin. Logs Expt. Admin. Log: Export all admin operating logs. Data is stored into a Confidential file.
Export Security Photo Expt. Security photos: Set a time duration of exporting security photos Security photos are saved in folder Export System File Expt. System File: Export all system settings and parameters Data is stored into a file. Import Management Import Admin Confidential Impt. Admin.: Import all admin. data from a file.
Import Part Users Impt. Part Users: Import part user‟s data from file. Import All Users Impt. All Users: Import data of all users from a file. Import User-List Impt. All Users: Import all ID and name information of users file. from a The contents of USERLIST.TXT file are list of + + . The range of user ID is from 1-99,999,999,999,999. Import System File Impt. System File: Import all system settings and parameters from a Confidential file.
Update Wallpaper Update the new wallpaper on a terminal. 240 * 320pix BMP/JPG file, and or . named to Update Prompt Voice Update Successful and Failed prompt audio on a terminal. PCM, 16000Hz, 16bit, stereo wave file, and named to and Keep audio length less than 1 second. Firmware Upgrade Upgrade a new firmware for a terminal. Firmware files are and
3.5 Security Security Main Menu Unlock Time Unlock Time: User can set duration time of unlock. The default duration is 3 seconds. The duration range is 1~255 seconds.
Delay Time: Set a time period for the door sensor. In the indicated period, the sensor will not detect singal. The default duration is 10 seconds. The duration range is 1~255 seconds. Timezone Timezone: limit user access within a indicated period (start time & end time). Start time is earlier than end time, then access is granted, for example: 00:00-23:59 Start time is later than end time, then access is nenied, for example: 06:00-06:00 or 06:00-05:50 Total 50 Timezone can be set.
Group Group: each group can set 3 different timezones. Holiday can be enable (1) or disable (0) for this group. Total 99 groups can be set. Advanced Combo: Combination Access, it combines several users from the selected group to gain one access priviliege. Anti-Passback (APB): check each IN and OUT status and determine an access priviliege for users. Combo and Anti-Passback fucntion cannot be used together. Combo Combo Time: a total time for one combination access process.
Anti-Passback (APB) Anti-Passback: has 4 mode, None, OUT, IN and IN+OUT. OUT mode: to gain valid and authorized OUT access priviliege, user‟s previous record must be correct and matched IN access. IN mode: to gain valid and authorized IN access priviliege, user‟s previous record must be correct and matched OUT access. IN+OUT mode: combine both OUT and IN mode together. Alarm Main Menu 4 types alarm: tamper alarm, door sensor alarm, face rejection alarm and duress alarm.
Door Sensor Alarm Door Sensor alarm is on, the alarm will activate by the door sensor status Door sensor funciton can be set in Security function. The default is OFF. Face Recjection Alarm Face Rejection alarm is on, the alarm will activate after the verifying rejection of one user exceed limit value. The default is OFF. Total rejected verification times The default duration is 3 times. The range is 1~9 times. Total duration of rejection alarm The default duration is 180 seconds.
Duress Alarm Duress alarm is on, the alarm will activate after a user enter duress password during verficiation. The default is OFF. Duress alarm will only provide a signal for the network via SDK. It will not activate alart on device. Duress password: a special password for users to enter as they meet threat during verficiation. The range is 8-bit digitals from 1~99999999.
3.
Date and Time Date and Time: System date and time can be set with this function Date Format: System date format can be set in 9 formats. Day-light Saving TIme DST Time: Set daylight saving time. Select proper DST format according to DST rule of your region. Default is off. Mode1 (Month-Day-Hour): DST begins with April 10 on 9am, and end to Sept. 10 on 9am. Mode2 (Month-Week-Day): DST time begins with 2nd Sunday, April on 9am, and end to 2nd Sunday, Sept on 9am.
Volume Set Volume: terminal support 4 modes to customers. The default is medium. Communication Communication: Network and Wiegand setting. Network DHCP DHCP turns on, the device will allocate IP/MASK/Gateway automatically from a router. User doesn‟t need to operate them DHCP turns off, user set the IP /MASK/Gateway manually. Ethernet: Set IP /MASK/Gateway for a device Communication Password Encrypt commucnication channel by password.
Push to Server Push to sever Switch: On/OFF The default is off. Record Data Switch: User can select record data/record+security photo data be pushed to the server. Server: User needs to set IP address and port of server. The default IP address is 192.168.0.3. Command Port (TCP) is 9920. Heart Beat Package Port (UDP) is 9924. Heart Beat Package delay is 60 seconds. The HBP delay range is 10~300 seconds.
Wiegand Wiegand Mode: Wiegand OUT and Wiegand IN The default type is OUT mode. Wiegand Type: System supports standard Wiegand protocol output on the follow list. The default type is Wiegand 26. Custom Type: User can define their own wiegand signal type for a special use. Content:The user can set Weigand output content with Card ID or User ID. The default content is User ID.
Pulse Width: Set proper pulse width for wiegand output to match the external wiegand input terminal. The default Pulse Width is 100 us. The pulse width range is 20~8000 us. Pulse Interval: Set proper pulse interval for wiegand output to match the external wiegand input terminal. The default Pulse Interval is 1000 us. The interval range is 200~20000 us. WG-IN Monitor: Test wiegand input signal value. Test WG-IN Value function appears in Wiegand IN mode.
Duplication Check: System will match new enrolled user with database to check this user already enrolled or not. If system displaying “Similar to ID XX”, admin is suggested to check this user for double enrollment. The default is OFF. Default: This operation will delete all data and configurations. And then initialize the device to factory setting. If the administrator , the terminal will be in factory mode! 3.6 System Info. Capacity Info.
Face: Current enrolled user numbers and total capacity of user numbers for face related recognition mode. Other: Current enrolled user numbers and total capacity of user numbers for card and ID+PIN related recognition mode. Record: Current record numbers and total capacity of record numbers. Sec. Photo: Current security photo numbers and total capacity of security photos. Unsent Records: Unsent record numbers while push to server mode is on.
Check LCD: Display Red, Green and Blue on the screen Check Keyboard: Follow the screen message to check all keys. Confidential Check Detection. Check Speaker.
Confidential Check RFID Cards. Check Network. Check USB Disk. Check Camera.
5. Appendix Appendix1. Product Specification User capacity 1,000 users for face related verification method; 10,000 users for other verification methods including card, card and photo, ID and Pin Record capacity Data Capacity: 200,000 Security Photo: 200,000 Verification methods Face Card and Face Card or Face Card Languages: English Simplified Chinese Recognition algorithm V3.1 Display: 3.
Appendix2. Caution Installation Environment Terminal should install inside of the room, and make sure the installation place far with the window/door/light more than 2 meters. Outside of the room Sunlight directly shines on the terminal through the window. Sunlight slanted shines on the terminal through the window. Restoration and restart When the system halted and cannot quit, you can remove the adapter to restore and restart the system, or you also can press to restart the terminal.
indoor temperature. The performance of this terminal will get worse, if the working temperature extend this temperature range. Please prevent the screen from oil or any sharp objects. Please use the equipped adapter for the terminal, the other unknown adapters will burn out the terminal. Warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the user‟s authority to operate the equipment. This device complies with part 15 of the FCC Rules.