You have chosen a hearing system from HANSATON We take pleasure in your choice and congratulate you on your decision, because with a HANSATON hearing system you own a highquality product of the most modern technology. For more than 50 years, we have been helping people with our devices to achieve better hearing and better speech understanding, hence a higher quality of life.
Contents Your hearing system Intended use General notes on safety Changing batteries Turning your hearing system on/off – Via battery compartment – Via pushbutton – Via remote control How to tell which system is which Adjusting volume – without switch – with switch – Via remote control Changing the hearing program Page Page Page Page Page Page Page Page Page Page Page Page Page Page 30 31 32 34 37 37 37 37 37 38 38 38 39 39 – Via program pushbutton – Via remote control Functionalities – i-com/i-com2 – Po
Program pushbutton Microphone entry Microphone entry Pull-string Battery compartment Hearingsystem shell Sound outlets Battery compartment Program pushbutton Hearing system shell Sound outlets Program pushbutton Battery compartment Volume control Hearing system shell Sound outlets How to tell which instrument is which: Red = right ear, blue = left ear 30
Intended use Symbole Hearing systems are intended to improve the hearing of hearing impaired persons. Diagnosis and prescription of a hearing system must be performed by hearing health specialists, e.g. ENT doctors, audiologists or acousticians. Read and follow the instructions of this user guide to avoid injuries or damage to the hear ing system. WARNING! points out a situation that could lead to serious injuries. CAUTION! dindicates a situation that could lead to minor and moderate injuries.
• Instruction. Indicates that something has to be done. Indicates an option that not every hearing system has. Ask your hearing system professional to check off the relevant information. General notes on safety ! 32 Your hearing system is sensitive to extreme heat, high humidity, strong mag netic fields (> 0.1T), Xrays and mechanical stress. • Do not expose your hearing system to extreme temperature or high humidity. • Do not leave it in direct sunlight.
i When using mobile telephones, however, electromagnetic field effects cannot be ruled out. WARNING! Choking hazard posed by small parts. • Keep hearing systems, batteries and accessories out of children‘s reach. • If swallowed consult a physician or hospital immediately. • If infants, small children or mentally disabled persons need to wear hearing systems ensure adequate supervision. WARNING! Risk in explosive environments, e.g.
Inserting the battery without tool Inserting the battery with tool • Open the battery compartment with a fingernail and swing the compartment right out. • Open the battery compartment and put the battery in the open compartment so that the negative pole faces into the compartment. • Close the battery compartment until you feel a sharp click. • Open the battery compartment with a fi ngernail and swing the compartment right out.
pole facing into the battery door. • Loosen the brush from the battery. • Close the battery until you feel a sharp click. With a new battery, it may take a few minutes for the battery to develop its full output. Only then should you close the battery-com partment.
Advice on Batteries • Batteries can be harmful if swallowed. Never put batteries in your mouth ! For this reason, keep batteries out of reach of children. • If a battery is inadvertently swallowed, please call a doctor immediately. • Always use new batteries. • Remove the batteries if the hearing system is to remain unused for a long time. • Failing batteries should be replaced immediately.
Switch your hearing system on and off Via battery compartment Switch on • Close the battery compartment. Switch off • Open the battery compartment. Via pushbutton Switch on • Press the pushbutton for 2 seconds. Switch off • Press the pushbutton for 2 seconds. Via remote control • Refer to the remote control user guide.
Adjusting volume Without switch The volume of the hearing system is adjusted automatically, no manual control is required. The volume decreases if you turn the switch anticlockwise (right hearing system) / clockwise (left hearing system). louder louder With switch Right hearing system Left hearing system The volume increases if you turn the switch clockwise (right hearing system) / anticlockwise (left hearing system).
Switching of hearing programs Via remote control • Refer to the remote control user guide. Via pushbutton • Use the program pushbutton to select one of the hearing programs individually programmed for you. • When changing, your hearing system uses signal sounds to indicate which program you have selected. The number of signal sounds is based on the relevant program (e. g.
Hearing program/Description • You can thus adjust your instrument to the relevant hearing situation and thus, for example, make use of the advantages of MultiMic technology, especially in conversation in groups. Via remote control • Refer to the remote control user guide.
Functionalities Your hearing system professional can activate or deactivate the following functionalities. • Move away from the source of interference if you experience difficulty. icom/i-com2 • automatically adjusts both hearing systems simultaneously to changes in the hearing system settings, e.g. volume and program. • allows use of a remote control. Power-on-delay • allows you to turn the hearing systems on with an automatic delay of 6, 12 or 18 seconds to avoid feedback (whistling).
Automatic telephone program • Hold a telephone near your hearing instrument. The hearing instrument automatically switches to the telephone program. Move the telephone away from your hearing instrument. The hearing instrument switches back to the previously used program i Not all telephones produce a magnetic field strong enough to activate the PhoneConnect function. In this case, use the PhoneConnect magnet, enclosed in your hearing instrument 42 package.
WARNING! • Keep magnets away from children. If swallowed consult a physician or hospital immediately. NOTICE Magnets can disturb electrical devices and delete stored data. • Keep magnets away from computers, color monitors, television sets, floppy discs, video and audio discs and other electronic equipment /devices. i When operating the hearing instrument in telecoil mode, the wireless function may cause a pulsing noise. This is due to the pick-up of the transmission signal.
Inserting and removing the hearing system 44 • Hold your hearing instrument between your thumb and forefi nger and insert it carefully into your auditory canal. • How to tell which instrument is which: red = right ear, blue = left ear • You can get it in the right position by twisting it slightly. • Pull the flap of your ear slightly up and back with one hand, pushing the hearing instrument a bit further in with the index finger of the other hand.
Advice on care • You are advised to use our HADEO care products to clean your hearing system. These products were developed specifi cally for this purpose and are available exclusively from your hearing instrument professional. • The hearing system itself must not be placed in water or cleaning fl uid. • The hearing system must be kept dry. Please put it in a HADEO DryBox, HADEO Drying Bag or Drying Container overnight to extract any moisture from the inside of the instrument.
Care Primer Our HADEO care primer can be obtained from your hearing instrument specialist who will be glad to advise you on any questions you may have about caringfor your system. 46 Accessories Remote control eMote/eMote2 The wireless function of your hearing systems allows you to use a remote control to change the program and volume of your hearing systems. For detailed information and instructions refer to the User guide or ask your hearing system professional.
i In case the hearing system is controlled by another person’s remote control, return to your hearing system professional with your remote control and hearing systems. connection it is possible to receive audio signals from your mobile, your television or your mp3player. For detailed information and instructions refer to the Media user guide or ask your hearing system professional.
Trouble shooting Should a problem occur, it can usually be corrected quickly. Use these troubleshooting tips to resolve simple issues. If you still encounter problems after trying these suggestions, consult your hearing system professional.
Problem Possible Solution Sound is weak or no sound Replace empty battery. Increase volume. Clean instrument. Close battery door completely or press and hold the program button for approximately 2 seconds. Instrument emits whistling sound Try reinserting the instrument. Clean instrument. Sound is distorted Replace empty battery. Lower volume. Clean instrument. Instrument emits signal tones Gently close battery compartment completely. Replace empty battery.
Technical Information FCC-ID: WU7-WL002ITE Operating frequencies: Fc = 3.28 MHz Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and 50 (2) this device must accept any interference received, including interference that may cause undesired operation.
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna.
Disposal information Within the European Union, the marked equipment is covered by „Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronical equipment“. Amended by „Directive 2003/108/EC“ (WEEE). i Recycle the device and batteries according to national regulations. 52 With the CE marking HANSATON confirms compliance with the European Directive 93/42/EEC concerning medical devices.
FDA information (valid for USA only) Use your hearing systems all day long The best way to ensure better hearing is to practice listening with your hearing systems until you are able to wear them comfortably all day. Generally, infrequent use of the hearing system does not provide you with the full benefit of amplification. Your hearing systems will not restore normal hearing. Hearing systems will not prevent or improve hearing impairment resulting from a physiological condition.
accelerated accumulation of cerumen (earwax). Also in rare cases, the otherwise non-allergenic material may cause a discharge from the ear, allergic reaction, or any other unusual condition. Please seek immediate consultation with a physician if these conditions occur.
(v) Unilateral hearing loss of sudden or recent onset within the previous 90 days. (vi) Audiometric air-bone gap equal to or greater than 15 decibels at 500 hertz (Hz), 1,000 Hz and 2,000 Hz. (vii) Visible evidence of significant cerumen accumulation or a foreign body in the ear canal. (viii) Pain or discomfort in the ear.
medical evaluation is to assure that all medically treatable conditions that may affect hearing are identified and treated before the hearing instrument is purchased. Following the medical evaluation, the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing instrument.
a hearing instrument for a period of time for a nominal fee after which you may decide if you want to purchase the hearing instrument. Federal law restricts the sale of hearing instruments to those individuals who have obtained a medical evaluation from a licensed physician. Federal law permits a fully informed adult to sign a waiver statement declining the medical evaluation for religious or personal beliefs that preclude consultation with a physician.
Identification information The year of manufacture is incorporated into the serial number. The warranty is based upon the date of purchase, not date of manufacture. The serial number may look similar to this sample: AJ12345. The second letter of this serial number refers to the date of manufacture of the hearing system. The letters progress in one-year increments, each reflecting the corresponding year.