User's Manual

Product Manual
Smart Brightness Thermometer
(BLE Version)
Switch/Reset Button
Screen Display
Vent
Bracket
Viscose Zone
Product Description
Maintenance
Maintenance
Avoid washing with water when cleaning the product, and avoid scrubbing
with pH-based detergents.
Soft magnetic sticker×1
Preparation for use
Connect your
phone to WIFI
Smart phone
Make sure that the product is within the effective coverage of the
smart phone (or Bluetooth gateway) network to ensure an effective
connection between the product and the smart phone (or Bluetooth
gateway) network.
Download and open the APP
Search for “Smart Life” in the App store or scan the QR code in the
manual to download and install the App. Press the “Register” button to
register an account if this is your first time use; if you already have an
account, press the “Login” button.
Scan the QR code to
download “Smart Life” App
Switch/Reset Button
Network Access SettingNetwork Access Setting Function Setting
Magnetic Mode
Gateway Connection
After successfully installing the battery on the device, and ensure that
the mobile phone is connected to the network and the smart gateway
has been successfully added;
Open the “Smart Life” App, on the "Smart Gateway" page, click the
"Add Sub Device" button;
Select " Temperature and Humidity Sensor" in the Device Type list;
After adding successfully, you can find the device in the "My Home" list.
Long press the reset button for more than 5 seconds, the
device restarts and enters the network configuration state;
Product Specifications
Smart Brightness Thermometer
(BLE Version)
Product Name
Wireless Protocol
Temperature Measurement Range 0~50°C
Humidity Measurement Range
Bluetooth
Battery Model
Temperature Accuracy
Humidity Accuracy
Light Detection Range
Light Perception Accuracy
±0.3
0%—99RH%
±3RH%
0-999lux
0.01lux
Product Size 66×66×11mm
Screen Size 45×45mm
45.0g
CR2032 button battery
Packing list
Thermo-hygrometer×1
User manual×1
Wall sticker×1
Product Weight
Switch Temperature Unit
The smart brightness thermometer senses the changes in the ambient light,
temperature, and humidity in real time, and can actively report to the user
end. At the same time, it combines with other products to realize diversified
smart home application scenarios.
Switch/Reset Button
After successfully adding, you can find the device in the "My Home" list.
Long press the reset button for more than 5 seconds, the
device restarts and enters the network configuration state;
Illumination linkage suggestion: After
the product is installed in a fixed
position, the actual detection value is
the detection environment value. For
example, if the light is suitable for the
environment and 100 lux is detected,
then when the illuminance is lower than
100 lux, the light needs to be turned on,
and the product trigger condition can be
set to be lower than 100 lux or 80 lux,
turn on the light in linkage.
Temperature linkage suggestion: If the
ambient temperature is higher than 30
, turn on the air conditioner for
cooling.
Humidity linkage suggestion: if the
ambient humidity is higher than 80%,
linkage open the dehumidifier.
Application Note
1 This product is intended for general consumption scenarios, please pay
attention to the application scenarios of the product;
2 The illuminance is restricted by the installation environment, position
and angle. The brightness value detected after the product is fixedly
installed is the detection value of the current position. The light sensor
hole on the front of the product is close to the true value when it faces the
light source vertically;
3 The illumination deviation fluctuates greatly, and there will be a
fluctuation deviation of about 10%;
4 Make sure that the ink screen is working within the specified
temperature range. If it exceeds the working temperature range, it may
work abnormally. Please place it in a normal environment as soon as
possible. Check the test data value after 10 minutes;
5 When low battery occurs, please replace the battery in time;
6 The ventilation holes of the product should not be immersed in water;
Battery power on and replacement
Battery power-on: Open the body support, pull out the isolation sheet to
power on.
Battery replacement: When the low battery icon
appears on the screen, the battery power is too low,
please replace the battery in time. At this time,
you need to open the body support, pry open the
battery cover, and buckle the product upside down.
Put the CR2032 battery into the battery
compartment with the negative electrode facing
down, and then press firmly against the buckle to close the back cover.
Light-sensing Hole
Soft Magnetic Sticker
Magnetically attractable objects
such as refrigerators
45°
The temperature unit displayed on
the screen of the smart brightness
thermometer can be switched
between Celsius and Fahrenheit
.
On the device side, short press
the button to switch the temperature
unit between Celsius and
Fahrenheit .
On the APP side, you need to
switch temperature unit at “Me” Page
in the smart APP.
Wall Sticker
Wall
Wall-mounted Mode
The smart brightness thermometer can be used with wall stickers and
used on the wall.
Take out the wall sticker in the package, stick the wall sticker on the
selected location, and then attach the smart brightness thermometer.
Adhesive use reminder: You need to choose a place where the wall is
clean and dry, and the surface is flat; after it is pasted, press it with your
hand for a while to ensure that it is firmly pasted.
The smart brightness thermometer can be used on the desktop.
Open the back cover halfway (at a 45° angle with the body), then the
smart brightness thermometer can be stably placed on the desktop.
Table Place Mode
The smart brightness thermometer can be combined with soft magnetic
stickers to be attached to the surface of magnetically attractable objects
such as refrigerators.
Stick the soft magnetic sticker on the back area of the product, and attach
the product to the surface of a magnetically attractable object such as a
refrigerator.
7 The light hole of the product cannot be blocked by objects or covered
with dirt;
8 The product is not suitable for use below 0, please stay away from
harsh environments such as high temperature and high humidity;
9 The temperature felt by the human body depends on many factors, such
as air temperature, heat radiation, relative humidity, human activities, etc.
When the temperature is 19°C~28°C and the relative humidity is
41%~65%, the human body feels more comfortable; The received
brightness also depends on many factors, such as weather, window
switch, light switch, position angle, etc. When the product desktop is flat,
the front light hole is vertically upward, and the brightness value above
200lux is more suitable for office work.
Phone Connection Directly
After successfully installing the battery on the device, make sure
that the phone is connected to the network;
Open the Smart Life App, click the "Add Sub Device" button on the
"+" page in the upper right corner;
The device will be automatically discovered on the smartphone .
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by
manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
The device has been evaluated to meet general RF exposure requirement. The device can
be used in portable exposure condition without restriction.

Summary of content (1 pages)