6566 ! STOP DO NOT RETURN TO THE STORE! If you discover missing or damaged parts, or if you have questions about the building process, please reach out to us directly for the fastest service. 24/7 Support help.backyardproducts.com Answers to frequently asked questions Business Hours (734) 242-6900 Monday - Friday ........... 8:00am - 6:00pm EST Saturday - Sunday .................................
(This page intentionally left blank.
ASSEMBLY MANUAL 16566 11/11/2022 A Backyard Products Company MAJESTIC 8' x 12' (244 x 366 cm) ACTUAL FLOOR SIZE IS 96" x 144" (244 x 366 cm) KEEP THIS MANUAL FOR FUTURE REFERENCE I M PO RTANT! READ INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING ASSEMBLY. BEFORE YOU BEGIN • BUILDING RESTRICTIONS AND APPROVALS Be sure to check local building department and homeowners association for specific restrictions and/ or requirements before building.
TOOLS Required ❑ Phillips Optional ❑ Tool Belt/ ❑ Utility Knife Screwdriver Nail Pouch ❑ Shingle Blades ❑ Drill / Driver ❑ 1/4" Drill Bit ❑ 3/8" Drill Bit ❑ 1/2" Drill Bit ❑ #2 Philips Drive Bit ❑ Tin Snips ❑ Caulk Gun (for drip edge) ❑ Chalk Line ❑ Paint Tools ❑ Hammer ❑ Nail Gun ❑ Pencil ❑ Ladder ❑ Tape Measure ❑ Square • gun nails ❑ Safety Glasses ❑ Level ❑ Gloves or Safety! Always use approved safety glasses during assembly.
ADDITIONAL MATERIALS FOUNDATION OR FLOOR MATERIALS • This kit includes a complete floor. • This shed kit does not include ANY leveling materials. • See the FLOOR LEVELING section on page 7 for recommended methods and suggested materials to properly level your floor, as this will vary depending on your specific site. REINFORCED WOOD FLOOR FRAME (OPTIONAL) IMPORTANT! This floor has been designed for general use.
PARTS IDENTIFICATION AND SIZES Part identification letters are stamped on some parts. WOOD SIZE CONVERSION CHART Treated lumber is stamped: Nominal Board Size 2x4 RS RS Check these locations for part stamp. Actual Size ..............1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1x4 .................3/4" x 3-1/2" (1,9 x 8,9 cm) 2x3 ..............1-1/2" x 2-1/2" (3,8 x 6,3 cm) 1x3 .................3/4" x 2-1/2" (3,8 x 6,3 cm) PARTS LIST INVENTORY YOUR PARTS before you begin.
SHELF DOORS RAFTERS PARTS LIST continued... x10 6" x 24" (15 x 61 cm) x10 AA x3 JF 2 x 4 x 55-3/16" (5 x 10 x 140 cm) 1 x 4 x 60" (2,5 x 10 x 152 cm) x2 OO x1 FQ x5 PT 2 x 3 x 96" (5 x 7,6 x 244 cm) x2 TP 2 x 4 x 96" (5 x 10 x 244 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 7,6 x 175,3 cm) 2 x 3 x 28-5/8" (5 x 7,6 x 73 cm) FLOOR PANELS ROOF PANELS SHELF PANELS PANEL PARTS LIST NOTE: Panel parts are not stamped. Shelf panels are 7/16" (1,1 cm) thick.
WALL PANEL & DOORS PARTS LIST NOTE: Panel parts are not stamped. x2 x2 x1 x1 x1 x1 x5 x1 x1 LEFT DOOR 3/8 x 48 x 84" (1 x 122 x 213 cm) RIGHT DOOR x1 FASTENER/HARDWARE BAG (Shown Actual Size) x133 1-1/2" (3,8 cm) x120 NOTE: If you are using a nail gun, nails may be used where screws are shown for quicker assembly. Length of nail must match screw length.
FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below. Leveling materials are not included in this kit. PREFERRED METHOD - 4x4 TREATED RUNNERS • 3" Screws angled into 4x4. • (2) at each point frame • and 4x4 touch. 12" (30,5 cm) Measurements to centers of 4x4's. MATERIAL REQUIRED 12" (30,5 cm) x2 4 x 4 x 12' (10 x 10 x 366 cm) Treated Lumber Fasteners for Frame to 4 x 4. (3" Screws shown as one option.
CONCRETE FOUNDATION If you choose to install your kit on a concrete slab refer to the diagram below. Treated Sill Plate Caulk between sill plate and concrete. C 3-1/2" (8,9 cm) B A OR DO 4" (10,2 cm) Building Size Actual Size 8' x 12' (243,2 x 365,8 cm) A 96" x 144" (243,2 x 365,8 cm) B 96" (243,2 cm) 137" (348 cm) Requires: x2 2 x 4 x 12' (5,1 x 10,2 x 344,5 cm) x2 2 x 4 x 8' (5,1 x 10,2 x 244 cm) MUST be treated lumber. MUST be treated lumber.
FLOOR FRAME PARTS REQUIRED: x2 x10 x2 Look for x44 TREATED TREATED 3" (7,6 cm) Stamp 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) TREATED 2 x 4 x 93" (5,1 x 10,2 x 236,2 cm) TREATED 2 x 4 x 96" (5,1 x 10,2 x 243,8 cm) BEGIN 1 Arrange parts as shown on a flat surface. Measure and mark. HINT: For easier nailing stand on frame. Secure with (2) 3" nails at each mark.
LEVEL AND SQUARE FLOOR FRAME Before attaching floor decking, it is important to level and square the floor frame. A level and square floor frame is required to correctly construct your shed. BEGIN 1 See page 8 for the preferred floor leveling method. Ensure that the frame is level before installing floor panels. 2 Check for frame squareness by measuring diagonally across corners. If the measurements are the same, the frame is square. The diagonal measurement will be approximately 173-1/16" (440 cm).
FLOOR PANELS PARTS REQUIRED: x62 3/4" GAUGE BLOCK 5/8 x 48 x 96" (1,6 x 121,9 x 243,2 cm) x1 BEGIN 2" (5,1 cm) Ensure your wall frame is square by installing one panel and squaring frame. Install panels with rough side up (painted grid lines). 1 Install (1) 48" x 96" panel with the 48" edge and corner flush to the floor frame (Fig A). Secure panel with (2) 2" nails in the corners. 2 Move to the opposite side.
FLOOR PANELS PARTS REQUIRED: x110 2" (5 cm) 5/8 x 48 x 96" (1,6 x 122 x 244 cm) x2 5 Install next 48" x 96" panel flush to installed panel. Install middle panel first. Secure with 2" nails 6" spaced apart on edges and 12" apart inside panels. 6 Install last 48" x 96" panel flush to installed panel. Secure with 2" nails 6" spaced apart on edges and 12" apart inside panels. 6" (15,2 cm) Flush Flush 12" (30,5 cm) DOOR Flush Flush Flush Flush FINISH Your floor panels are installed.
IMPORTANT! DO OR Ensure that the floor frame is level after installing floor panels. Re-level if necessary. • Use the floor as a stable work surface for wall construction. HINT: • Organize your assembly procedure during the build process to avoid over-handling of the walls.
SIDE WALL FRAMES PARTS REQUIRED: x4 NK x14 FU x4 PT 2 x 3 x 48" (5 x 7,6 x 122 cm) x64 3" (7,6 cm) 2 x 3 x 78-1/2" (5 x 7,6 x 199 cm) 2 x 3 x 96" (5 x 7,6 x 244 cm) Build two identical side wall frames. BEGIN 1 Arrange parts on edge on floor. Measure and mark. Secure with (2) 3" nails at each mark. HINT: For easier nailing stand on frame.
LEFT SIDE WALL PANELS PARTS REQUIRED: 48 x 84" 122 x 213 cm) x1 x1 x45 RK 2 x 3 x 13" (5 x 7,6 x 33 cm) as SPACER 2" (5 cm) GAA 3/4" GAUGE BLOCK Install all panels with the primed side facing up. Ensure your wall frame is square by installing one panel and squaring frame. BEGIN 1 Install (1) 48 x 84" panel on wall frame, as shown. 2 Use the gauge block to mark the 3/4" measurement on the wall stud. Use RK as a 1-1/2" gauge block at top. Secure panel with (2) 2" nails in the corners (Fig. A).
LEFT SIDE WALL PANELS PARTS REQUIRED: x90 2" (5 cm) GAA 48 x 84" 122 x 213 cm) x1 x1 4 RK 3/4" GAUGE BLOCK x1 2 x 3 x 13" (5 x 7,6 x 33 cm) as SPACER Install the middle 48"x 84" panel flush to installed panel. Secure with 2" nails spaced 6" apart on edges and 12" apart inside panel. For squareness maintain the 3/4" 1-1/2" measurement along top (19 mm) of panel and 3/4" along panel edge. 1-1/2" Flush (3,8 cm) HINT: Use RK as 1-1/2" gauge.
RIGHT SIDE WALL PANELS PARTS REQUIRED: 48 x 84" 122 x 213 cm) x1 x1 x45 RK 2 x 3 x 13" (5 x 7,6 x 33 cm) as SPACER GAA 3/4" GAUGE BLOCK Square your right wall frame as shown on page 16. BEGIN 1 Install (1) 48 x 84" panel on wall frame, as shown. Use the gauge block to mark the 3/4" measurement on the wall stud. Use RK as a 1-1/2" gauge block at top. Secure the panel with 2" nails spaced 6" apart on edges and 12" apart inside panel.
RIGHT SIDE WALL PANELS PARTS REQUIRED: x90 2" (5 cm) GAA 48 x 84" 122 x 213 cm) x2 x1 RK 2 3/4" GAUGE BLOCK 2 x 3 x 13" (5 x 7,6 x 33 cm) as SPACER Install the middle 48"x 84" panel flush to installed panel. Secure with 2" nails spaced 6" apart on edges and 12" apart inside panel. For squareness maintain the 3/4" 1-1/2" measurement along (19 mm) top of panel and 3/4" along panel edge. 1-1/2" Flush (3,8 cm) HINT: Use RK as 1-1/2" gauge.
BACK WALL PARTS REQUIRED: x1 x1 RK 48 x 96" (122 x 244 cm) x11 1-1/2" (3,8 cm) 2 x 3 x 13" (5 x 7,6 x 33 cm) x1 FS 2 x 3 x 35-1/4" (5 x 7,6 x 89,5 cm) x2 PS 2 x 3 x 91" (5 x 7,6 x 231 cm) Install all panels with the primed side facing up. BEGIN 1 Arrange 2x3 parts on flat on floor, as shown. 2 Install left panel on FS and PS. Secure with only 1-1/2" nails 6" spaced apart. Secure FS first; 1" from panel bottom. 3 Fasten PS flush to FS. Secure with 1-1/2" nails spaced 12" apart.
BACK WALL PARTS REQUIRED: x1 x1 x1 x1 AQ 2 x 3 x 31" (5 x 7,6 x 79 cm) TEMPORARY SUPPORT EY x15 5/8 x 3 x 9" (1,6 x 7,6 x 23 cm) FS 1-1/2" (3,8 cm) 2 x 3 x 35-1/4" (5 x 7,6 x 89,5 cm) PS 2 x 3 x 91" (5 x 7,6 x 231 cm) 4 Arrange parts on flat beneath panel as shown. 5 Place temporary spacer EY on the lower PS. Install FS flush to spacer. Secure with 1-1/2" nails spaced 6" apart. 6 Place PS flush to FS. Hold the 74-5/8" measurement. Secure with 1-1/2" nails spaced 12" apart.
BACK WALL PARTS REQUIRED: x1 x26 RK 2 x 3 x 13" (5 x 7,6 x 33 cm) 48 x 96" (122 x 244 cm) x1 8 1-1/2" (3,8 cm) Install right panel onto frame. Secure with 1-1/2" nails spaced 6" apart on edges and 12" apart inside panel.
BACK WALL PARTS REQUIRED: x2 RK 2 x 3 x 13" (5 x 7,6 x 33 cm) x1 3/8 x 12 x 24" (1 x 30,5 x 61 cm) x1 3/8 x 12 x 24" (1 x 30,5 x 61 cm) x12 9 Install left and right 12" x 24" upper gable panels flush to installed panels. Secure with 1-1/2" nails spaced evenly. 10 Install (2) wall panel supports RK on flat, at measurements shown. Secure with (3) 1-1/2" nails (Fig. A). 1-1/2" (3,8 cm) Flush Line up seams. 2-1/2" (6,4 cm) RK Fig.
FRONT WALL FRAME PARTS REQUIRED: x1 x1 x1 x6 UX 2 x 4 x 64" (5 x 10 x 162,5 cm) NA 2 x 3 x 9" (5 x 7,6 x 23 cm) DI 1 x 3 x 12" (2,5 x 7,6 x 30,5 cm) BEGIN 1 Arrange NA and UX on flat on floor as shown. 2 Install DI on top of NA flush to top (Fig A.). Secure DI to NA and UX with (6) 2" nails, as shown. 32" (77,5 cm) 32" (77,5 cm) NA 2-1/2" (6,3 cm) UX 3-1/2" (8,9 cm) Flush Flush to TOP Fig.
FRONT WALL FRAME PARTS REQUIRED: x2 x1 x8 FV 3" (7,6 cm) 2 x 3 x 82-1/2" (5 x 7,6 x 210 cm) FW Temporary Support 2 x 3 x 84" (5 x 7,6 x 213 cm) Pre-Assembled 7/16 x 25-3/4 x 48" (1,1 x 65,4 x 122 cm) x1 BEGIN 1 2 Arrange parts on edge on floor, as shown. Secure FW to studs with 3" nails (Fig. A). Place (1) roof panel as temporary support under pre-assembled frame. Arrange Pre-Assembled Frame on flat, with DI facing down. Position Frame 9" from bottom of FW.
FRONT WALL FRAME PARTS REQUIRED: x1 x2 Temporary Support FR 3" (7,6 cm) x2 2 x 3 x 23" (5 x 7,6 x 58 cm) 3" (7,6 cm) 7/16 x 25-3/4 x 48" (1,1 x 65,4 x 122 cm) x3 4 Secure NA with (2) 3" nails (Fig. A). 5 Use (2) roof panels as temporary supports above frame. Install FR centered, as shown. Secure with (2) 3" screws (Fig. B). Leave temporary supports in place until after front panels are installed. Fig. A (2) 3" (7,6 cm) Nails Flush NA Temporary Support 2-1/2" (6,3 cm) Fig.
FRONT WALL PANELS PARTS REQUIRED: Temporary Support x1 x24 1-1/2" (3,8 cm) 7/16 x 25-3/4 x 48" (1,1 x 65,4 x 122 cm) x3 Install all panels with the primed side facing up. Handle panels with care to avoid breakage. BEGIN 1 Install left panel on front wall frame, as shown. 1-1/4" (3,2 cm) Hold the 1-1/4" and 1/4" measurement. Secure with 1-1/2" nails spaced 6" apart. Maintain 64" (162,5 cm) measurement between studs and square frame.
FRONT WALL PANELS PARTS REQUIRED: x1 x1 12 x 24" (30,5 x 61 cm) x1 12 x 24" (30,5 x 61 cm) x30 2 Install right wall panel on front wall frame. Secure with 1-1/2" nails spaced 6" apart. Maintain 64" (162,5 cm) measurement between studs and square frame. 3 Install right and left 12" x 24" gable panels flush to installed panels, as shown. Secure with 1-1/2" nails evenly spaced. Flush Temporary Supports Line up seams.
BACK WALL INSTALLATION PARTS REQUIRED (TEMPORARY): x1 x6 PT x4 2 x 3 x 96" (5 x 7,6 x 244 cm) x18 3" (7,6 cm) 3" (7,6 cm) 2" (5 cm) BEGIN 1 Center back wall assembly on the floor. 2 Install PT as a temporary brace. Secure with (2) 3" screws. 3" (7,6 cm) Screws PT 3 Secure lower edge of panel to floor frame with 2" nails spaced 6" apart. Angle nail into floor frame (Fig. A). 4 Secure RK, with (3) 3" nails as shown. Angle nails into floor frame (Fig. A).
SIDE WALLS INSTALLATION x24 x84 x4 3" (7,6 cm) 3" (7,6 cm) 2" (5 cm) BEGIN 1 Center side wall on floor front to back. Secure the lower back wall corner to the side wall frame with (1) 2" nail (Fig. A). 2" (5 cm) Nail DOOR Fig. A CENTER 2 2" (5 cm) Nail Ensure the measurement between the panel edges is the same along the entire length. Secure wall with (1) 2" nail in the upper corner (Fig. B). SAME MEASUREMENT Fig.
FRONT WALL INSTALLATION x4 x30 x2 3" (7,6 cm) 3" (7,6 cm) 2" (5 cm) BEGIN 1 Center front wall on floor side-to-side. Secure the wall panels to the floor with 2" nails spaced 6" apart. Angle nails into floor frame (Fig. A). Secure the lower front wall corner to the side wall stud with (1) 2" nail (Fig. B). Fig. B 2" (5 cm) Nail Fig. A 2" (5 cm) Nail 6" 6" (15 cm) (15 cm) CENTER 2" (5 cm) Nail 2 Ensure the measurement between the panel edges is the same along the entire length.
LOFT SUPPORTS PARTS REQUIRED: x2 x8 3" (7,6 cm) TP 2 x 4 x 96" (5 x 10 x 244 cm) BEGIN 1 Measure from the top of back wall loft support to the floor. Measure and mark the same measurement on the back side of side wall studs at each side, as shown. 2 Install (2) loft supports TP level against back side of studs at marked locations. Secure with (2) 3" nails at each end. Mark Mark TP Loft Support SAME MEASUREMENT FLOOR FINISH Your loft supports are now installed.
SHELF FRAME PARTS REQUIRED: x2 3" (7,6 cm) x8 x1 3" (7,6 cm) PT 2 x 3 x 96" (5 x 7,6 x 244 cm) BEGIN 1 Install PT flush to top of loft support (Fig A). and level against studs and with top edge of loft support. Secure PT with (2) 3" nails at each stud. At the door side of PT, secure with (2) 3" screws. Flush at top of loft support. Fig. A (2) 3" (7,6 cm) Screws at door end. 3" (7,6 cm) Nails Flush (2) 3" (7,6 cm) Nails Loft Support NOTE: There will be a gap at the end of PT.
SHELF FRAME PARTS REQUIRED: x1 x4 3" (7,6 cm) PT 2 x 3 x 96" (5 x 7,6 x 244 cm) Assistance may be required to install PT. 2 Install 2nd PT flush against loft support (Fig. A). Secure with (2) 3" screws. 3 Ensure that PT is level. Secure to front wall stud with (2) 3" screws. Front Wall Support (2) 3" (7,6 cm) Screws PT Loft Support Flush NOTE: There will be a gap at the end of PT. Flush Fig.
WORKBENCH PARTS REQUIRED: x1 x4 3" (7,6 cm) PT 2 x 3 x 96" (5 x 7,6 x 244 cm) BEGIN 1 Measure the top of back wall workbench support from floor. Transfer that measurement and mark the same measurement on the back side of side wall studs at each side. 2 Install PT to back side of studs at marks. Ensure that PT is level. Secure with (2) 3" nails at each side. Workbench Support Mark stud. Mark stud.
WORKBENCH PARTS REQUIRED: x1 3" (7,6 cm) FQ x20 2 x 3 x 28-5/8" (5 x 7,6 x 73 cm) 2" (5 cm) 7/16 x 23-7/8 x 91" (1,1 x 61 x 231 cm) x1 3 x4 Insert workbench panel into the gap in back wall upright. Secure with 2" nails, as shown. Fit panel into gap. 23-7/8" (61 cm) 4 Install FQ to upright and workbench, as shown. Secure with (4) 3" screws (Fig. A). Angle top screw into FQ. Flush Fig. A (4) 3" (7,6 cm) Screws FQ Angle bottom screw so it does not protrude past panel.
LOFT PANELS PARTS REQUIRED: x8 7/16 x 44-1/4 x 48" (1,1 x 112 x 122 cm) x2 2" (5 cm) BEGIN 1 Install loft panels onto the (3) loft supports, centered from side-to-side and flush with the back wall panel. Fit panels into gap. IMPORTANT! Secure loft panels with only (4) 2" nails in each panel, to allow squaring the roof. You will complete nailing the loft panels later. CENTER Fit panels into gap.
SHELF PANELS PARTS REQUIRED: x2 x40 7/16 x 11-7/8 x 96" (1,1 x 30 x 244 cm) 2" (5 cm) BEGIN 1 Place shelf panel onto the left wall shelf frame, flush to shelf support and loft panel. Secure with 2" nails, as shown. Repeat on opposite side. Flush LEFT WALL Flush FINISH You have finished installing your shelf panels. LOFT AND SHELVING CAPACITY Attention: Load not to exceed 250 lbs evenly distributed across loft. Attention: Load not to exceed 100 lbs evenly distributed across shelf.
RAFTERS PARTS REQUIRED: x10 x120 6" x 24" (15 x 61 cm) x10 AA 2" (5 cm) 2 x 4 x 55-3/16" (5 x 10 x 140 cm) Build 5 rafter assemblies. BEGIN 1 Place (2) rafter-halves in the corner of back and side walls. Flush rafter at peak. Secure gusset to rafter with 2" nails in a staggered pattern, as shown. 2 Flip over rafter assembly and install 2nd gusset to back side. HINT: Use floor and walls to help assemble rafters! 96" (244 cm) Fit base of rafters in corners of back wall.
RAFTERS PARTS REQUIRED: x20 3" (7,6 cm) x10 Preassembled x5 2" (5 cm) x 10 BEGIN 1 Install rafters directly over studs and flush to wall panel. Check that you have the measurements shown. 2 Secure ends of rafters with one 2" screw Into rafter ends (Fig. A). Secure rafters to top plates with (2) 3" screws at an angle (Fig. B, Fig. C). MEASUREMENTS ARE FROM INSIDE OF PANELS. MEASUREMENTS ARE TO CENTER OF RAFTERS. 24” 61 cm 24” 61 cm 24” 61 cm 24” 61 cm 24” 61 cm 24” 61 cm Align over studs.
GABLE TRIM PARTS REQUIRED: x4 x1 ¸1 HTA 2 x 4 x 59-1/8" (5 x 10 x 150,2 cm) Temporary Straight Edge OO 2 x 3 x 69" (5 x 7,6 x 175,3 cm) BEGIN Arrange HTA on floor as shown. Using OO as a straight edge, mark a line 1-1/4" (3,2 cm) down length of HTA (Fig. A). Repeat the process to mark all trim. 1-1/4" (3,2 cm) OO HTA Fig. A Mark a line.
GABLE TRIM PARTS REQUIRED: x4 x28 HTA 1-1/4" (3,2 cm) 2 x 4 x 59-1/8" (5 x 10 x 150 cm) Install (1) HTA 1-1/4" up from front panel edge and center with panel seam (Fig. A). Secure the trim with (7) 1-1/4" screws from inside. Secure with (2) screws at seam (Fig. B). 2 Upper gable slightly from lower panels. ItNOTE: is important to panels securemay thebeside walloffset in the following order. If this occurs, mark a line on upper panel to match lower wall panel (Fig. B).
GABLE TRIM PARTS REQUIRED: x2 x24 AWR 1-1/4" (3,2 cm) 2 x 3 x 41-7/8" (5 x 7,6 x 106 cm) BEGIN 1 Install AWR level over seam of front wall panels with 1-1/4" screws from inside, as shown. Repeat to install AWR on back gable. AWR AWR FINISH Your horizontal gable trim is now installed.
ROOF PANELS PARTS REQUIRED: x2 x4 2" (5 cm) x2 7/16 x 11-1/4 x 96" (1,1 x 28,6 x 244 cm) 3/4" GAUGE BLOCK 7/16 x 48 x 96" (1,1 x 122 x 244 cm) x2 x2 7/16 x 11-1/4 x 25-3/4" (1,1 x 29 x 65,4 cm) 7/16 x 25-3/4 x 48" (1,1 x 65,4 x 122 cm) Install roof panels with the rough side facing up (painted grid lines). Roof panels may cause serious injury until securely fastened. You must square the roof by attaching one panel fist. Use the panels’ long edge as a lever to bring your roof into square.
ROOF PANELS PARTS REQUIRED: x174 2" (5 cm) 3/4" GAUGE BLOCK 3 Secure the lower edge of the 48"x 96" panel and secure with (1) 2" nail into each rafter (Fig. E). Move to the top of the 48"x 96" panel and maintain the spacing between the center of the rafters. Secure panel with (1) 2" nail into each rafter (Fig. E). 12" (30,5 cm) Flush Completely secure the roof panel with 2" nails spaced 6" apart on edges and 12" apart inside panel. 4 5 6" (15 cm) Gauge Block Fig.
COLLAR TIES PARTS REQUIRED: x3 JF 2" (5 cm) 1 x 4 x 60" (2,5 x 10 x 152 cm) BEGIN 1 x18 Install and level (3) collar ties JF on first (3) rafters past door opening. Do not install collar ties over loft. Secure with 2" nails as shown. For best appearance, we recommend installing collar ties on rafters facing away from door opening. Flush Flush JF x3 FINISH Your collar ties are now installed.
LOFT PANELS (continued...) PARTS REQUIRED: x22 BEGIN 1 Continue securing loft panels with 2" nails evenly spaced, as shown. Attention: Load not to exceed 250 lbs evenly distributed across loft. FINISH Your loft panels are now installed.
SOFFIT TRIM PARTS REQUIRED: x2 x2 x8 x40 3" (7,6 cm) AN 1-1/4" (3,2 cm) 2 x 4 x 48-3/4" (5 x 10 x 124 cm) TP 2 x 4 x 96" (5 x 10 x 244 cm) BEGIN 1 Install soffit trim flush to side wall panels and under roof panels (Fig. A). Secure with 1-1/4" screws. 2 Secure ends of TP and AN with (2) 3" screws through gable trim (Fig. A). Repeat steps to install soffit trim on opposite side. Screws 3” (7,6 cm) Flush AN 48-3/4” (124 cm) Screws 3” (7,6 cm) 96” (244 cm) TP Screws 1-1/4” (3,2 cm) Fig.
CORNER TRIM x64 PARTS REQUIRED: x4 3/8 x 1-3/4 x 82-1/4" (0,9 x 4,4 x 209 cm) x2 3/8 x 1-3/4 x 80-7/8" (0,9 x 4,4 x 205,4 cm) x2 3/8 x 1-3/4 x 80-7/8" (0,9 x 4,4 x 205,4 cm) 2" (5 cm) BEGIN 1 Install 82-1/4" corner trim flush to under side of soffit trim and flush along front of side wall panel (Fig. A). Secure trim with 2" finishing nails (8 per side) spaced evenly. 2 Install front and back angled 80-7/8" corner trim flush along length of 82-1/4" trim and flush up to gable trim (Fig. A).
DOORS PARTS REQUIRED: x1 x1 x4 GAA 3" (7,6 cm) 1 x 3 x 5" (2,5 x 7,6 x 12,7 cm) OO x2 1-1/2 x 2-1/2 x 69" (3,8 x 7,6 x 175,3 cm) TEMPORARY SUPPORT 1-1/4" (3,2 cm) HINT: x1 Look for 3/8" SPACER attached to doors. x1 Left Door Right Door BEGIN 1 Arrange parts as shown on flat surface. 3/8" offset is to top. Look for red (right) and green (left) on hinge board. Install temporary supports OO and GAA as shown. Tighten securely.
DOORS x6 PARTS REQUIRED: x1 OO 3" (7,6 cm) 1-1/2 x 2-1/2 x 69" (3,8 x 7,6 x 175,3 cm) TEMPORARY SUPPORT 2 Install temporary support OO flush under wall panels. Secure with (2) 3" screws (Fig. A). OO Fig. A 3 Flush against wall panels. OO Center doors on panel seam, as shown (Fig. B). Ensure ledger board remains flush under panels. 4 Secure hinge boards into wall supports and floor. Secure with (10) 3" screws, as shown. Ensure sure penetrate into framing and floor (Fig. C, D).
DOOR PARTS REQUIRED: x56 3/4" (1,9 cm) BEGIN 1 Secure door trim with 3/4" screws from behind, as shown. Door Panel Install 3/4" screws from inside. Fig. A Door Trim CENTER CENTER No screws in this area of RIGHT DOOR. Door hardware will be installed here later. CENTER CENTER Two Screws Fig. B FINISH You have reinforced your door trim.
WINDOWS PARTS REQUIRED: x4 10-1/2 x 32-1/2" (27 x 82,5 cm) x2 BEGIN 1 Install windows in front panel opening. Ensure window are level. Secure with (2) screws at top of windows. Caulk behind frame near edge before installing. Do not fully tighten screws. Adjust gap between windows to approximately 1/2". Apply high quality exterior-grade caulk to seal window. 2 Screws 2 Screws Approx. 1/2" (1,3 cm) HINT: Caulk behind frame near edge before installing.
WINDOWS TRIM PARTS REQUIRED: x1 2 x14 ZJ 2" (5 cm) 5/8 x 2-1/2 x 72" (1,6 x 6,3 x 183 cm) Center ZJ over doors. Secure with (14) 2" finishing nails into framing. Do not nail into window flange. HINT: Mark edge of window frame on ZJ. Inside Framing Do not nail into window flange. Mark Center.
WINDOW TRIM PARTS REQUIRED: x3 x6 EY 2" (5 cm) 5/8 x 2-1/2 x 9" (1,6 x6,3 x 23 cm) 3 Install (3) EY with 2" nails into framing as shown. NOTE: Use marks on ZJ for locating window flange. Do not nail into window flange. Remove temporary screws after installing trim. EY x3 2" Nails from outside. Mark Mark Keep aligned. Keep aligned.
WINDOWS PARTS REQUIRED: x1 4 x10 ZJ x7 2" (5 cm) 3/4" (1,9 cm) 5/8 x 3 x 72" (1,6 x 7,6 x 183 cm) Install ZJ centered over windows. Secure with (7) 2" finishing nails into framing. Do not nail into window flange. ZJ OUTSIDE OF SHED Keep aligned. Flush Flush CAUTION! Do not nail into window flange! 5 From inside, install 3/4" screws into ZJ and outer (2) EY. Do not screw into window flange. INSIDE OF SHED Install 3/4" (1,9 cm) screws from inside.
DOOR WEATHERSTRIP PARTS REQUIRED: x2 x14 2" (5 cm) OO 2 x 3 x 69" (5 x 7,6 x 175 cm) BEGIN 1 With left door closed, center (1) weatherstrip OO vertically on the left door in the door opening (Fig. A). OO will offset the left door 1" past the door trim by 1" (Fig. B). Secure OO with (7) 3" screws through outside trim into OO (Fig. B) 2 Install OO centered vertically in door opening (Fig. A). OO will offset the right door 1" IN from the door trim (Fig. C).
DOOR HARDWARE PARTS REQUIRED: x8 x2 1" (2,5 cm) 5/16" (0,8 cm) Drill Bit BEGIN Place spring bolt onto OO in open position with bolt end 3/8" down from frame. Bolt is open when loop is contacting base (Fig A). 1 Mark and pre-drill holes for screws. 2 Install bolt with screws supplied and drill 5/16" hole for bolt to extend into. 3 Place bolt onto OO in open position with bolt end 1/2" up from floor. Bolt is open when loop is contacting base (Fig B). Mark and pre-drill holes for screws.
LEFT WALL WINDOW FRAME PARTS REQUIRED: x2 x8 LV 3" (7,6 cm) x12 2 x 3 x 22-1/2" (5 x 7,6 x 56 cm) 2" (5 cm) BEGIN 1 Install window frame parts LV flush along window opening cutout. 1-1/2" (3,8 cm) Secure parts LV with (2) 3" nails at each connection. Flush Flush 68-1/8" (173 cm) LV Flush 3" (7,6 cm) Nails 38-1/8" (96,8 cm) 2 Secure panel to window framing with 2" nails spaced 6" apart. 2" (5,1 cm) Nails FINISH Your window framing is now installed.
WINDOW AND WINDOW TRIM PARTS REQUIRED: x4 1-1/4" (3,2 cm) x1 11-3/8" (28,9 cm) BEGIN 1 Mark center of window frame as shown. Measure over 11-3/8" and mark. 2 Seal window with high-quality exterior-grade caulk before installing (Fig. A). 3 Secure window with (4) 1-1/4" screws, as shown. Ensure window is level. 11-3/8" (28,9 cm) CENTER CENTER CENTER CENTER 1-1/4" (3,2 cm) Screws Fig. A Caulk behind frame near edge.
WINDOW TRIM PARTS REQUIRED: x2 x2 x16 2" (5 cm) DT 19/32 x 2-1/2 x 28-1/8" (1,5 x 6,3 x 71,4 cm) AZ 19/32 x 2-1/2 x 30-1/8" (1,5 x 6,3 x 76,5 cm) 4 Place the inside edge of AZ 11-3/8" apart from the center of window, as shown (Fig. B). Fig. B CENTER OF WINDOW 11-3/8" 11-3/8" (28,9 cm) (28,9 cm) Center trim vertically on window. Secure with 2" finishing nails at locations shown. Nail into window frame and studs behind. CENTER OF WINDOW AZ 2" finishing nails into wall frame. AZ Fig.
DOOR HARDWARE PARTS REQUIRED: x2 x1 x2 1-1/4" (3,2 cm) 1" (2,5 cm) 1/2" (13 mm) Drill Bit 1/4" (6 mm) Drill Bit BEGIN 1 Measure and mark location of hole on outside of right door as shown (Fig. A). Pre-drill hole with 1/4" drill. 2 Re-drill hole with 1/2" drill (Fig. B). Keep drilled hole square to trim to avoid breaking edge of 2x3. RIGHT DOOR 1-1/2" (3,8 cm) TOP VIEW Fig. A Fig. B 1/2" 1,3 cm 35-3/4" 90 cm SIDE VIEW 3 1-1/2" 3,8 cm 1/4" Pre-drill and 1/2" Drill-through.
VENTS PARTS REQUIRED: x12 1/2" (1,3 cm) 8" x 16" (20,3 x 35,6 cm) x2 ¸1 BEGIN Install (1) vent near the floor and (1) vent near the eave. Install vents on opposing walls. Mark locations for vents in side walls. Caulk behind vent flange. Secure with 1/2" screws. Upper Side Wall Vent 3"– 5" (7,6 – 12,7 cm) Caulk 6" (15,2 cm) 14" (35,6 cm) Side of Shed 14" (35,6 cm) Side of Shed 4-1/4" (10,8 cm) Caulk 6" (15,2 cm) 3 – 5" (7,6 – 12,7 cm) Lower Side Wall Vent FINISH Your vents are now installed.
PAINT & CAULK - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: • Bottom edge of all siding and trim • Inside of doors and all 4 edges Note: Prime all un-primed exterior wood before painting.
SHINGLES - NOT INCLUDED • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. Notch SHINGLE NAIL PATTERN 1" (2,5 cm) 1/2" (1,3 cm) Notch Sealing Strip 1" (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS. BEGIN 1 Install first starter row upside down and color up with a 1" overhang at back and bottom of roof panel. Use (4) nails per shingle.
SHINGLES continued... 2 2 Beginning at front of shed, install first row of shingles with notch at 1" past roof edge or flush with drip edge. Roof Deck FRONT OF SHED 1" (2,5 cm) Notch BACK OF SHED Flush with starter row. - or - Drip Edge Flush with starter row. Notch 3 Install second row of shingles flush at top of first row's rain slots. Ensure 1" overhang or flush to drip edge at front, stagger each row. FRONT OF SHED BACK OF SHED 1" (2,5 cm) Notch Flush with rain slots.
SHINGLES continued... 5 Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife. Cut Off. 5" (12,7 cm) MAX. CUT Top of rain slot. 5" (12,7 cm) or less. • If more than 5" to rain slot you must install another row of shingles. 6 Repeat steps 1 - 5 to shingle the opposite side of your roof. Trim shingles at ridge.
SHINGLES - RIDGE CAP • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN 1 Cut shingles into three pieces. Hint: use cut-off pieces first. 2" (5 cm) 2" (5 cm) 2" (5 cm) 2" (5 cm 2" (5 cm) 2" (5 cm) Score shingle, then snap-off angled cut. Weather Seal Top of slot. Note: • You will need about 30 - 32 cut pieces. 2 30 to 32 Pieces Install first ridge cap flush to shingles at front, as shown. (1) Nail per side through weather seal.
SHINGLES - RIDGE CAP continued... 4 Continue installing ridge cap to back of roof. 5 Make sure there is 4" between the shingle-color and edge of shingles. 4" (10 cm) 6 Trim cap off flush to shingles When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot. Cap 7 Install flush to shingles. Flush to shingles (2) Nails per side. FINISH You have finished your ridge cap.
16566 8' x 12' Order Form CATEGORY PART SIZE PART ITEM # BUILDING QTY. PART ID 2X3 Door side studs Over transom header Top & Btm Plates "A" \ Horz. Supp.
LIMITED CONDITIONAL WARRANTY* Backyard Storage Solutions, LLC warrants the following: 1. Every product is warranted from defects in workmanship and manufacturing for 1 year. 2. All accessories, hardware and metal components are warranted for 2 years. 3. All Oriented Strand Board (OSB) is warranted for 2 years 4. Siding and Trim is warranted for 10 years. 5. Solar Shed windows are warranted for 1 year. 6. Cedar lumber is warranted for 15 years. 7. Preserved Pine is warranted for 10 years. 8.