HES K100 Aperio Series Wireless Cabinet Lock Installation and Operating Instructions 2x AA Lithium Batteries required. Use of other types of batteries, such as alkaline, will significantly decrease battery life. Products Specifications Wireless Frequency: 2.4GHz, IEEE 802.15.4, using AES 128-bit encryption Lock Battery Type: AA Lithium, 1.5 Volts (V) Battery Life: 50,000 cycles* *All battery life claims are approximate and based on a set configuration profile.
Recommended Tools Flathead Drivers — 3/32”, 3/16” Drill, Drill Bits — 1/16”, 3/16”, 1/2” Phillips Drivers — P0, P2 Pencil, Wire Stripper, Level, Square, Ruler, Punch, Scissors Hardware Specifications Table 1 – Shaft Length Door Thickness 1/16” – 1/2” >1/2” – 1½” >1½” – 2¼” Shaft Used L1 L2 L3 Table 2 – Mounting Screw Length for Various Door Thickness Door Thickness Reader Mounting 1/16” Coupling Nut and 3” Rod Coupling Nut and 3” Rod Coupling Nut and 3” Rod Coupling Nut and 3” Rod Coupling Nut and 3”
Package Contents Reader Strike Plate Installation Template Lock Body Threadlock Pillow Pack Mechanical Key Override Double Door Bracket Hardware 2-56 X 7/16” 2x (A) 8-32 X 5/16” (B) 6-32 X 5/16” 3x (C) 6 X 1/2" 6x (D) Lithium Batteries 2x 8-32 Nut (J) 8-32 X 2-3/4” 2x (E) Page 3 of 17 8-32 X 1-3/4” 2x (F) For more information visit website assaabloyesh.com 8-32 X 2-1/2” 2x (G) P/N: 3080006.
Lock Orientation Options Orientation B Orientation A Orientation C Prepping the Cabinet/Drawer Face 1. Separate Strike Plate Template. Page 4 of 17 For more information visit website assaabloyesh.com 2. Establish centerline (for double door cabinet prep go to page 6). P/N: 3080006.
3. Measure cabinet wall thickness and mark offset line on face of cabinet/drawer. The offset line should match with the interior edge of the cabinet wall. 5. Align template to offset line and centerline. Remove backing and apply template onto cabinet/drawer face. 4. Continue centerline to face of cabinet/drawer 6. Use punch to mark drilling locations then drill mounting holes. If using mechanical key override, drill key override hole as well.
Prepping the Cabinet/Drawer Face (Double Door) 1. Establish center line on inside of stationary door. 2. Continue center line onto outside face of cabinet. 3. Align offset line on template to the edge of the stationary door and align center line with the established center line above. Remove backing and apply template to cabinet face. Continue with Step 6 in previous section. Page 6 of 17 For more information visit website assaabloyesh.com P/N: 3080006.
Reader Installation 1. Align reader with mounting holes and pull cable through as shown. Trim Threaded rod to length as outlined in table 2. 2. Add Threadlock to threaded rod. Secure Reader to cabinet/drawer using the cut threaded rod and coupling nut. DO NOT overtighten. Mechanical Override (Optional) 1. Slide Override into slot as shown. Page 7 of 17 For more information visit website assaabloyesh.com 2. Ensure that override retracts latch bolt before installation.
Lock Body Installation 1. Insert reader cable through hole in back of lock body. 2. Align lock body to mounting holes andsecure to cabinet/drawer face using 2x screw F and 2x screw D. If thick cabinet/drawer then use 2x screw E or 2x screw G instead of 2x screw F. DO NOT over tighten. 3. Plug cable into slot on lock body. 5. Any excess cable should be inserted into the cavity as shown below. Page 8 of 17 4. Tuck excess cable into lock body cavity as shown. 6.
Installing the Batteries 1. Install AA lithium batteries in appropriate position. 2. Install cover and secure using 2x screw A. Mechanical Key Override (Optional) Mechanical key override cam lock sold separately. 1. Insert cam lock through the outside of the cabinet/drawer face and secure with locking nut. Insert the end of Cam into the mechanical override and secure with nut as shown. Important Note – Reader MUST be programmed before installing the strike plate.
Strike Plate Installation 1. Align strike plate template to centerline and edge of cabinet. Drill mounting holes. 2. Secure strike plate to inside cabinet wall using 2x screw D, but do not fully tighten. Adjust strike plate so the edge is flush with the cabinet wall edge then tighten. 3. After the strike plate is in the desired position, fasten screw D into strike plate as shown below. Page 10 of 17 For more information visit website assaabloyesh.com P/N: 3080006.
Double Door Strike Installation 1. Align Double door bracket with mounting holes from the strike plate template. Secure double door bracket using 3x screw D. 2. Secure strike plate to double door bracket using 3x screw D as shown below. Page 11 of 17 For more information visit website assaabloyesh.com P/N: 3080006.
LED Codes Page 12 of 17 For more information visit website assaabloyesh.com P/N: 3080006.
Aperio Hub Technical Data – AH20 Approvals CE, ETL, FCC, IC, C-Tick Safety and emissions FCC 47CFR Part 15 subpart B and subpart C; IC RSS-210 EN ETSI 301 489-17 v2.1.1; ENETSI 300 328 v1.7.1; EN 60950-1 ed.2 2007 Dimensions 82x82x37 Power Supply 8-24 VDC Current 250 mA minimum Internal Antenna 2cross polarized dipoles External Antenna One reverse polarity SMA external antenna connector. Optional antenna type dipole with max antenna gain of 3.9dBi (Part No.
Connecting the Hub The following applies only to Aperio factory paired kits with AH20 Hubs. Connect the Wiegand D1, D0, red, and green LED signals. Note: The Green LED input is used to grant access to the cabinet lock. If the Green LED signal is not available to indicate approved access, the approval input can be activated by a relay with “NO” attached to Green LED and “C” to GND. The Red LED input is used to indicate access denied.
FCC Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
fabricant, peut causer des interferences nuisibles aux communications radio. Rien ne garantit cependant que l'interférence ne se produira pas dans une installation particulière. Si cet équipement provoque des interférences nuisibles à la réception radio ou de télévision, qui peut être déterminé en comparant et en l'éteignant, l'utilisateur est encouragé à essayer de corriger les interférence par une ou plusieurs des mesures suivantes: 1. Réorienter ou déplacer l'antenne de réception. 2.
Page 17 of 17 For more information visit website assaabloyesh.com P/N: 3080006.