KS200-640 Server Cabinet Lock Series Installation Instructions HES, Inc. Phoenix, AZ 1.800.626.7590 www.hesinnovations.
External Interface Signals Summary: Lock Signal Name Vin Unlock Tamper / Door Position + Tamper / Door Position – Wiegand Data 0 Wiegand Data 1 Green LED Red LED Ground/Return Lock Signal Direction and Wire Color Input, Red/24 AWG Input, Orange/24 AWG Output, Yellow/24 AWG Output, Blue/24 AWG Output, Green/24 AWG Output, White/24 AWG Input, Brown/24 AWG Input, White/Brown/24 AWG Input, Black/24 AWG Electrical Interface Power to Reader Wetted Relay Contact Closure (0–35 VDC) Dry Contact (0–35 VDC, <100mA)
Installation Steps 1. Installing an SFIC Core 2. Preparing the Cabinet 3. Installing the Lock 4. Installing the Handing Selector 5. Installing the Wiring 6. Testing the Lock with the Access Control 3085006.002 Rev.
1. Installing an SFIC Core NOTE 1: A key override (SFIC) provides a backup entry method in the rare case the KS200 or EAC is inactive (Recommended). NOTE 2: The included SFIC cam has been tested with Medeco and Sargent 6- or 7-pin SFIC cores. 1. REMOVE plug from handle 6-pin 7-pin 2. INSERT core into SFIC cam using the included spacers. 3. INSERT SFIC cam into lock 2. Preparing the Cabinet 1. LOCATE the 1” [25 mm] x 6” [150 mm] lock cutout on the door (some doors may require modification). 2.
3. Installing the Lock 3. SLIDE lock into cutout. NOTE: (Optional) The DPS signal is closed when the handle is resting in its locked position. The DPS circuit can be extended to include normally open DPS switches arranged in a series to monitor additional doors and panels. DPS Extension Cable Switch #1 (SPST-NO): Provided DPS Switches (SPSTNO): As Needed 2. PERFORM the following to extend the DPS Circuit. a. REMOVE the DPS jumper. b. CONNECT the included DPS extension cable. c.
5. ATTACH rear bracket with screws. 6. ENSURE that the lock is fully secured and flush to the mounting surface in order to depress tamper switch on back of device for correct operation. NOTE: Tamper Switch If the tamper switch is not fully depressed, the lock opens the Tamper/DPS+/- contact. 7. IF the tamper switch is not fully closed, THEN REMOVE the tamper contact, AND ENSURE the lock is closed. 4.
5. Attaching the Wiring 1. CONNECT the 10-position Molex Micro-Fit 3.0™ Cable between the KS200 and the EAC. 2. ENSURE the following power cabling guidelines are followed: Wire AWG 20 AWG 22 AWG 24 AWG Supply Voltage Allowed Cable Length (ft.)* 12 419 24 3217 12 264 24 2023 12 166 24 1272 * Round trip loss. V = 2 x I x R x xft xft = V / (2 x I x R) 6. Testing the Lock with the Access Control System 1.
FCC Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.